OBSERVATION ON ION DYNAMICS

Slides:



Advertisements
Similar presentations
Dr. Christos Giannakopoulos Dr. Basil Psiloglou Meteorological and pollution factors affecting hospital admissions in Athens, Greece ENSEMBLES WP6.2 Meeting.
Advertisements

Microscale structure of air ion spatial and temporal distribution: some problems Hyytiälä
Steffen M. Noe, Ahto Kangur, Urmas Hõrrak, Marko Kaasik SMEAR Estonia - Current state and further development.
New particle formation in Amazon: Clouds, rain and ions Radovan Krejci 1,2, Modris Matisans 1, Peter Tunved 1, Hanna Manninen 2, John Backman 2, Luciana.
Soot Particle Aerosol Mass Spectrometer: Development, Validation, and Initial Application T. B. Onasch,A. Trimborn,E. C. Fortner,J. T. Jayne,G. L. Kok,L.
D. Waddicor, G. Vaughan, K. Bower, T. Choularton, H. Coe, M. Flynn, M. Gallagher, P. Williams Aerosol observations and growth rates in the TTL.
CHAPTER 6 Statistical Analysis of Experimental Data
ULTRAFINE PM IN NEAR GROUND LAYER OF URBAN ATMOSPHERE, PRAGUE 2002/2003 JAN HOVORKA, LUBOMÍR BETUŠ ; Institute.
Introduction A new methodology is developed for integrating complementary ground-based data sources to provide consistent ozone vertical distribution time.
Ionisation as a precursor to aerosol formation
Ny-Ålesund Seminars, October Black carbon (BC) belongs to what is generally termed Short Lived Climate Forcers (SLCF). This means that the.
Results from the SMEAR III urban measurement station
Technical tool to evaluate the effectiveness of control measures I. ALLEGRINI and C. PERRINO Consiglio Nazionale delle Ricerche ISTITUTO sull’INQUINAMENTO.
SUBMICRON AEROSOL PARTICLES IN A SMALL SETTLEMENT NEAR HIGHWAY J. HOVORKA, Z. STAŇKOVÁ Institute for Environmental.
Online measurements of chemical composition and size distribution of submicron aerosol particles in east Baltic region Inga Rimšelytė Institute of Physics.
KL-parameterization of atmospheric aerosol size distribution University of Tartu, Institute of Physics Growth of nanometer particles.
Climate and How They Change By Mr. V. Calzada And Mrs. Swanson.
FINESTION a complete dataset of routine air ion measurements 2003 – 2006 in co-operation with: Urmas Hõrrak, Kaupo Komsaare,
BASIC STATISTICAL CONCEPTS Statistical Moments & Probability Density Functions Ocean is not “stationary” “Stationary” - statistical properties remain constant.
Estimating of neutral nanoparticles according to measurements of intermediate ions Hyytiälä Kaupo Komsaare & Urmas Hõrrak.
Diurnal and Seasonal Variations of Nitrogen Oxides Within Snowpack Air and the Overlying Atmosphere at Summit, Greenland C. Toro 1, R.E. Honrath 1†, L.J.
Four open datasets of atmospheric ion and aerosol measurements with acknowledgements to colleagues providing the data for open access.
Ion-Induced Nucleation of Atmospheric Aerosols Peter H. McMurry, PI Kenjiro (Ken) Iida, Graduate Student Department of Mechanical Engineering University.
A new mobility analyzer for routine measurement of atmospheric aerosol in the diameter range of 0.4−7.5 nm Institute of Physics, University.
Experimental study of the “rain effect” on the mobility distribution of air ions. Experiments with water jet. U. Hõrrak, H. Tammet, E.Tamm, A. Mirme. Institute.
Displaying the Observed Distribution of Quantitative Variables Histogram –Divide the range of the variable into equally spaced intervals - called bins.
OBSERVATION ON ION DYNAMICS Urmas Hõrrak, Hannes Tammet Institute of Environmental Physics, University of Tartu, 18 Ülikooli St., Tartu, Estonia.
Thunderstorm Dynamics Group Atmospheric ions and new particle formation For RAC meeting, Presented by Deveandraa Siingh The New particle formation (NPF)
Check-ins 1. What is the most abundant gas in the atmosphere? What is the second most abundant gas in the atmosphere? Together, these two comprise what.
Results and discussion Ground based characterization of biomass burning aerosols during the South American Biomass Burning Analysis (SAMBBA) field experiment.
Temporal Variations of 7Be and its AMAD over “Demokritos” GAW station
Presented by: Robyn D. Williams EAS 6410 April 19, 2004
Unit 9 Section 2: Solar Energy and the Atmosphere
Disciplines of Science, ch. 16
Statistical Methods Michael J. Watts
Weather Data Summary.
Experimental study of the “rain effect” on the mobility distribution of air ions. Experiments with water jet. U. Hõrrak, H. Tammet, E.Tamm, A. Mirme.
Statistical Methods Michael J. Watts
Daytime variations of AOD and PM2
EUROEPI2010 -EPIDEMIOLOGY AND PUBLIC HELTH IN AN EVOLVING EUROPE
Kaupo Komsaare & Urmas Hõrrak
Antecedent Environments Conducive to the Production of Extreme Temperature and Precipitation Events in the United States Andrew C. Winters, Daniel Keyser,
Mesoscale variability of surface ozone dynamics
Hyytiälä Microscale structure of air ion spatial and temporal distribution: some problems Hyytiälä
Colin Michel1, C. Amelynck3, M. Aubinet1, A. Bachy1, P. Delaplace2, A
Copyright © 2009 Pearson Education, Inc.
Project progress report WP2
mesoscale climate dynamics
Measurements of brown carbon in and around clouds
Solar Energy and the Atmosphere
The role of weather conditions on PM2.5 concentrations in Beijing
Constructing Climate Graphs
FINESTION a complete dataset of routine air ion measurements – 2006
STA 291 Spring 2008 Lecture 5 Dustin Lueker.
ATOC 4720: class 17 Atmospheric aerosols
STA 291 Spring 2008 Lecture 5 Dustin Lueker.
Weather: Characteristics & Fronts
Debye-like shielding effect on low-cloud electricity by the radioactive aerosol after Fukushima nuclear accident M. Yamauchi1, M. Takeda2, M. Makino3,
LAND SURFACE AND AIR TEMPERATURE AT CLEAR AND OVERCAST SKIES
Copyright © 2014 Pearson Education, Inc.
Chapter 12-Meteorology.
Patterns of Water Demand Eng. Mona Al-Gharbawi Eng. Ayman Al-Afifi
Describing Data: Numerical Measures
EQ: What is the impact of climate on Georgia’s growth and development?
Scatterplots, Association and Correlation
COLLECTING, ORGANIZING, AND DISPLAYING DATA
Particle Size and Size Distributions
Patterns of Water Demand
Weather Condition of the atmosphere at a certain place and time.
Empa, Air Pollution/Environmental Technologies
Presentation transcript:

OBSERVATION ON ION DYNAMICS Urmas Hõrrak, Hannes Tammet Institute of Environmental Physics, University of Tartu, 18 Ülikooli St., 50090 Tartu, Estonia. E-mail: Urmas.Horrak@ut.ee

Location of Tahkuse Observatory   ESTONIA

Measurements Location: Tahkuse Observatory (58°31'N 24°56'E), a sparsely populated rural region.  Instrumentation: three original multichannel aspiration spectrometers (second-order differential mobility analyzers). Method: particle classification by electrical mobilities. Mobility range: 0.00041–3.14 cm2V–1s–1, logarithmically divided into 20 intervals. Mobility spectra of positive and negative ions are measured in every 5 minute. Height of measurements: 5 m above the ground. The database consists of 8900 hourly average spectra measured during the period Sept. 1993 – Oct. 1994.

Diagram of the measuring system and the small air ion spectrometer (cross-section). E is electrometer, HVS is high voltage supply VS is voltage supply. External dimensions of the cylindrical aspiration spectrometer: height 695 mm, diameter 122 mm.

Classification of air ions Average spectra of air ions at Tahkuse. Sept.1993 - Oct.1994.

Classification of air ions and aerosol particles Class of air ions Mobility range cm2 V–1 s–1 Diameter range* Class of particles Small cluster ions 1.3 – 3.2 0.36 – 0.85 Clusters Big cluster ions 0.5 – 1.3 0.85 – 1.6 Intermediate ions 0.034 – 0.5 1.6 – 7.4 Nanometer particles Light large ions 0.0042 – 0.034 7.4 – 22 Ultrafine particles Heavy large ions 0.00087 – 0.0042 22 – 79 Aitken particles * Estimates of equivalent diameter ranges assume single charged particles. Hõrrak, U., Salm, J. and Tammet, H. (2000) Statistical characterization of air ion mobility spectra at Tahkuse Observatory: Classification of air ions. J. Geophys. Res. Atmospheres 105, 9291–9302.

Small or cluster ions Average spectra of air ions. Sept. 1993 - Oct. 1994. Tahkuse Observatory

Average characteristics of small ions (means and standard deviations) Average mobility spectra of small ions. Sept. 1993 – Oct. 1994. Tahkuse. Average characteristics of small ions (means and standard deviations) Parameter Small ions, cm–3 Mean mobility, cm2 V 1 s1 Conductivity of small ions, fS m1 Polarity (+) 274 96 1.36 0.06 6.0 2.1 Polarity (–) 245 88 1.53 0.10 Ratio (+/–) 1.13 0.07 0.89 0.04 1.00 0.05

The frequency distributions (histograms) of the mean mobility of positive and negative small ions

Diurnal variation in the concentration of small ions (0. 5–3 Diurnal variation in the concentration of small ions (0.5–3.14 cm2V1s1) and wind speed. August 21 – August 30, 1994.

Average diurnal variation in small (or cluster) ion concentration Average diurnal variation of positive cluster ion concentration in the warm season (Sept.1993, May – Sept. 1994) and in the cold season (Nov. 1993 – April 1994). Statistics: median, box (25% and 75%) and whiskers (10% and 90% quantiles).

Variation in the activity concentration of radon at Tahkuse Variation in the activity concentration of radon at Tahkuse. August 19 - September 18, 1998.

Correlation coefficients (in percent) between positive air ion mobility fractions. November 1, 1993 – Aprill 30, 1994.

Scatterplot: the concentrations of small positive ions (0. 5–3 Scatterplot: the concentrations of small positive ions (0.5–3.2 cm2 V1 s1) versus heavy large ions (52 –79 nm). Cold season (Nov. 1993 – April 1994), Warm season (May–Sept. 1994).

Evolution of cluster ion mobility spectra in wintertime The effect of aerosol particle concentration on the mobility distribution of cluster ions

Evolution of cluster ion mobility spectra in summertime The combined effect of the concentration aerosol particles and radon (Rn 222) on the mobility distribution of cluster ions

Small and big cluster ions It is rational to subdivide cluster ions (0.5–0.14 cm2V1s1) into two classes of small and big cluster ions (with the boundary at 1.3 cm2V–1s–1 for negative ions and 1.0 cm2V1s1 for positive ions). Subdividing leads to more distinct shape of the diurnal variation in the concentration of these ion classes. The ratio of the concentrations of small and big cluster ions is closely correlated with the mean mobility of cluster ions (the correlation coefficients are 97% and 95% for positive and negative small ions, respectively).

Diurnal variation in the median concentration of positive and negative small cluster ions and big cluster ions in the warm season (Sept. 1993, May – Sept. 1994).

Average diurnal variation of the natural mean mobility of small positive and negative ions in the warm season (Sept. 1993, May – Sept. 1994). Statistics: median, box (25% and 75%) and whiskers (10% and 90% quantiles).

Variations in the mean mobility of negative and positive small ions and air temperature at Tahkuse, September 1–30, 1993.

Variations in the mean mobility of negative and positive small ions and air temperature at Tahkuse. December 23, 1993 - January 31, 1994

Variations in the mean mobility of negative and positive small ions and accumulation mode aerosol particle (100–500 nm) concentration at Tahkuse from April 14 to May 16, 1994.

Conclusions The average diurnal variation of cluster ions at Tahkuse had the ordinary shape for the continental stations of high latitude. The results are in accordance with the hypothesis that radon is the main ionizing agent, which causes the variation in the ionization rate, and therefore in the concentration of cluster ions near the ground. The different behavior of small and big cluster ions during diurnal cycle causes the diurnal variation in the natural mean mobility of small ions. The diurnal variation of the mean mobility was considerable only in the warm season while in the cold season the mean mobility was mainly correlated with the changes in air masses.

The factors of the mobility distribution of cluster ions We suppose that the changes in the mobility distribution of cluster ions are due to the changes in the chemical composition and the concentration of some trace gases or vapors in the air, probably generated by photochemical reactions; the changes in the ionization rate and the concentration of aerosol particles. The last two factors have an effect on the lifetime of cluster ions.

Burst events of intermediate ions (charged nanometer particles ) in the atmospheric air Average spectra of air ions. Sept. 1993 - Oct. 1994. Tahkuse Observatory

Variation in the concentration of positive intermediate ions, air temperature, and relative humidity at Tahkuse, Sept. 11–27, 1993.

Time series of the concentration of positive intermediate ions, air temperature, relative and absolute humidity. Tahkuse, Oct. 10 - 28, 1994.

Variation in the concentration of positive intermediate ions, air temperature, relative and absolute humidity. Tahkuse, November 5 - 18, 1993 relative and

Time variation of the concentration of aerosol particles (100 - 560 nm) and intermediate ions (1.6 - 7.4 nm). Tahkuse 14.04 - 16. 05. 1994. and

Variation in the concentration of positive intermediate ions, the mean mobility of negative and positive small ions and relative humidity. Sept. 11–27, 1993.

Scatterplot of the mean mobility of small ions versus intermediate ion concentration. Sept. 1993 – Oct.1994.

Contour plot of the evolution of air ion spectrum at Tahkuse Contour plot of the evolution of air ion spectrum at Tahkuse. October 20, 1994

Evolution of positive air ion mobility spectra. Oct. 20, 1994.

Evolution of positive ion mobility spectra at Tahkuse. March 22, 1994.

Contour plot of the evolution of air ion spectrum at Tahkuse Contour plot of the evolution of air ion spectrum at Tahkuse. May 22, 1996.

Contour plot of positive air ion spectrum. 19.11 - 20.11.1995, Tahkuse

Average diurnal variation of positive air ion concentration during the burst events. Tahkuse 1.09.1993 - 27.10.1994.

Diurnal variation in the median concentration of intermediate ions (diameter 2.1–7.4 nm), light large ions (7.4–22 nm) and heavy large ions (22–79 nm) in the warm season. Sept. 1993, May – Sept.  1994.

Evolution of positive and negative air ion mobility spectra Evolution of positive and negative air ion mobility spectra. December 5, 1993, Tahkuse.

Time variations in the fraction number concentrations of aerosol particles (PNC), positive air ions (INC) and global radiation. Nov.19, 1995.

Location of the measurement points (Tahkuse, Tõravere and Kellasaare)

Monthly concentrations of intermediate ions (1. 6 - 7. 4 nm) Sept Monthly concentrations of intermediate ions (1.6 - 7.4 nm) Sept. 1993 – Oct. 1994

Statistics of intermediate ion burst events. Sept. 1993- Oct. 1994 Statistics of intermediate ion burst events. Sept.1993- Oct.1994. The number of days in the month, when the concentration of positive intermediate ions exceeds a certain value. * burst of short duration: October, December within 2 hours, January within 3 hours more than 100 cm3.

CONCLUSIONS The size distribution of aerosol ions (1.6–22 nm) is strongly affected by the nucleation bursts. The photochemical nucleation can initiate a burst of intermediate ion concentration (charged aerosol particles in the size range of 1.6–7.4 nm) and subsequent evolution of aerosol ion size spectra below 80 nm. The generated new aerosol particles grow toward sizes 10–15 nm during 2–3 hours. In general, the disturbed region of air ion size spectra affected by the bursts is 1.1–34 nm (0.002–1.0 cm2V1s1) including the groups of big cluster ions, nanometer particles and a fraction of Aitken particles. The frequency of occurrence of the bursts (about 80 per year) has peaks in spring and autumn.

Diurnal variation of aerosol ion concentration during the non–burst days During the non–burst days, the average diurnal variation in the concentration of aerosol ions was weak, in general, and displayed different behavior considering the cold and warm season.

Diurnal variation in the median concentration of positive cluster ions (0.5–3.14 cm2V1s1), intermediate ions (2.1–7.4 nm), light large ions (7.4–22 nm) and heavy large ions (22–79 nm) in the cold season (November – March).

Diurnal variation in the median concentration of positive cluster ions (0.5–3.14 cm2V1s1), intermediate ions (2.1–7.4 nm), light large ions (7.4–22 nm) and heavy large ions (22–79 nm) in the warm season (May – September).

Diurnal variation in the median concentration of heavy large ions (22-79 nm) and small ions in the warm season (Sept. 1993, May - Sept. 1994) and in the cold season (Nov. 1993 - March 1994).

The diurnal variation of heavy large ion concentration in the warm season is generally opposite to that in the cold season This contrast can be explained by the differences in the mixing of the boundary layer air and by the different processes of aerosol particle generation (combustion of fuel versus gas-to-particle conversion and radiolytic processes initiated by 222Rn, 220Rn decay).