HVI HIPOT TEST SET Pft sERIES.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

MANUAL TRANSMISSION ELECTRICAL. OBJECTIVES n Diagnose electrical problems by logic and symptom description. n Perform troubleshooting procedures using.
The D.C. Scout Battery Distribution System Ground Locator
Isolation Verification Control Mining - Marine - Transit – Solutions LIVE Distributed By Locksafe Industrial Safety Equipment.
Chapter 12 Transformers. Chapter 12 Transformers.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Measurement Basics II Dr. Len Trombetta 1 ECE 2100 Power supply: current meter and current limit Light Bulb and LED!
Chapter 7 – Serial-Parallel Circuits
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Qualified Electrical Worker
© 2011 Ericson Manufacturing, Willoughby, Ohio
VAT: Volt Ampere Tester
Purpose Learn how to use basic electronic equipment:
Residential Wiring By: Ing. Hector M Lugo-Cordero, MS 03/25/2009.
3200A Electrical Test Equipment Calibrator. Automatic Loop Correction To simplify calibration of loop testers, the 3200A can be fitted with the Auto.
3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical.
Institute Of Applied Technology ATE 1012 Grade 10 Eng. Rose Hasan.
 Four Components of a circuit  Power supply  Conductor  Load device  Controlling device  Power Supply  Generator  Line source (wall outlet)  Transformer.
7.2.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Resistance Between Two Given Points in.
Settings & Adjustments. Settings & Adjustments.
Class exercise 1 Find the equivalent resistance of the following circuit.
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
Topic 7 - Electricity in the Home Transmission of Electricity Power Grid Transformers are used to change the amount of voltage with hardly any energy loss.
Copyright  Progressive Business Publications Electrical Safety.
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
1 of 7 Displays Voltage Displays Current Adjusts Voltage Output voltage is available at these terminals; the + is at a higher voltage than the - Photo.
Physics 2225: Working With Electronic Equipment Purpose  Learn how to use basic electronic equipment: Digital multi meter Oscilloscope Function generator.
Limiting Maximum Current of the Power Supply. Which Meter has almost zero resistance? Current meter R i  0  e.g.,  R i 
3200 Electrical Test Equipment Calibrator The Total Solution to Electrical Test Equipment Calibration.
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
Grounding.
Main contacts closed – RED Colour with ON
Auto turn off battery charger Auto turn off battery charger.
Measurement Basics II Dr. Dave Shattuck 1 ECE 2100 Power supply: current meter and current limit Light Bulb and LED!
Electric Circuits Chapter 14, Section 4. Circuits consist of an energy source, a load, wires, and in some cases, a switch.
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
Electrical Safety.
DVOM Not-So Basics.
Grounding.
(5) DMM & Oscilloscope.
EMT 451 CHAPTER 4 DC METER Prepared by: Rosemizi Bin Abd Rahim.
Limiting Maximum Current of the Power Supply
DESCRIPTION AND GUIDE TO OPERATIONS
PRESENTED BY:AMOD SHAKYA. Power Circuit –connectoin with motor using contactor Control Circuit-using switch make a holding circuit.
به نام خدا عکس هایی در خصوص ایمنی برق کاری از مهین نورپور سارا صارمی
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
Open circuit Test and Short circuit Test
MPU-16A / FPU-16 TEST UNIT TUTORIAL
The D.C. Scout Battery Distribution System Ground Locator
THREE-PHASE GROUND-FAULT BASICS
Qualified Electrical Worker
Personal Protective Equipment
Circuits Lab Introduction
Electrical Safety.
Electronic Control Systems Week 2
Introduction and Overview of Aerial Lift Testing Per ANSI 92
Vibration Monitoring System M14
Overcurrent Protection— Fuses and Circuit Breakers
Flotection: Building Main Shutoff System
Grounds Tester GT400 or GT600.
The Safe Use of Electricity
ENTER OUR FRIEND MR. RELAY
Electrical components and systems
ST800 Service Tester, 800 Amps.
CORDLESS PHASING TESTER
Presented by: HJ Arnett Industries, LLC
Fluid Power System Electrical Control
Presentation transcript:

HVI HIPOT TEST SET Pft sERIES

oBJECTIVES SPECIFICATION SETUP OPERATION SPECIAL OPERATIONS

Standard features of the PFT Series of include: Continuously adjustable output voltage Fixed overload, factory set to 120% of variable transformer rated output current “Zero Start” and External Interlock provision Secondary connected dual-range voltmeter Shielded output cable precludes unnecessary insulated support of the cable One piece portable design Transit protected meters prevent meter damage between test sites

M A I N P O W E R The MAIN POWER pushbutton switch provides the power to the control and power circuits. The neon lamp in the switch will light when the power is on and voltage is available through the input line cord. The INPUT FUSE located electrically before the MAIN POWER switch provides line fault protection for the unit.

E X T I N T L K ( E X T E R N A L I N T E R L O C K ) The Ext Intlk connector is provided to allow for a normally open safety interlock switch to control the energizing of the high voltage output. A safety plug may be used instead for a safety switch.

H I G H V O L T A G E O N / O F F The HIGH VOLTAGE ON and OFF pushbuttons control the high voltage power circuits. The red and green LEDs provide life long positive indication of the circuit status. The red LED lights when high voltage is energized and the green LED lights when the high voltage is de-energized. The HIGH VOLTAGE ON button will not operate until the OUTPUT CONTROL has been set to ZERO.

O U T P U T C O N T R O L The OUTPUT control variable transformer adjusts the output voltage. The 0-10 markings on the knob indicate the low to high setting. The control must be at ZERO (0) to energize the high voltage circuits. The output control must always be returned to zero at the completion of testing, prior to de-energizing the output.

A N A L O G V O L T M E T E R A N D R A N G E S W I T C H The KILOVOLT METER and associated range switch allows for more accurate output voltage readings. 1-% precision resistors minimize the need for re-calibration due to aging shift. See Voltmeter Re-calibration in Section 3 for details on calibration.

A N A L O G C U R R E N T M E T E R The CURRENT METER is for accurate secondary load current readings. The range multiplier switch (X1, X10, X100) allows readings to be taken as low as .1mA (5 divisions) and up to 100mA.

L O A D R E T U R N C O N N E C T O R The LOAD RETURN connector is for the low side of the test load. It connects to the shielded return lead for more accurate load current readings.

R E T U R N M O D E The RETURN MODE switch allows for accurate secondary load current readings. In the GUARD position, all ground currents are shunted around the meter. The load must be isolated from ground to use in the GUARD position. In the GROUND position, the return point is grounded and all currents (load and ground losses) are metered.

SETTING UP THE Equipment Select a location for the unit that will allow easy viewing of the meters at a safe distance from the test object. Be sure that all the controls are off, in their de-energized or fully counterclockwise position. Secure a ground test lead to the panel. The Ground post on the front panel should be used for that purpose. A black test lead with black boot has been provided for the ground connection. A second ground lead is provided for two-piece units for the grounding of the high voltage section. Insert the EXT INTLK plug into the socket on the panel. The plug may also be wired to a normally open contact of a safety switch for added protection.

SETTING UP THE Equipment (cont.) Prior to connecting the output cable to the test sample, be sure that the test sample is de-energized. The red booted alligator clamp on the output cable is used to connect the output cable to the test object. The black alligator clamp on the return cable is used to connect the other side of the test sample object.

Operating the Equipment Select the desired VOLTMETER RANGE for the test voltage level expected. (Start with the lowest voltage setting and then move up to the high setting if necessary) With the OUTPUT control at zero (zero start interlock engaged), depress the HV ON pushbutton. The HV ON light will glow. Depress the MAIN POWER switch to energize the control circuits. Increase the output by rotating the OUTPUT control slowly clockwise until the desired output voltage is reached.

Operating the Equipment Maintain the output voltage for the test time specified in your standard procedures. After the test is complete, rotate the OUTPUT control to zero, prior to depressing the HV OFF pushbutton. If the test sample fails during the test, the internal overload relay will de-energize the high voltage. This relay is in the primary circuit and is sensitive to primary current overloads. The overload is set to 120% of the rated current of the variable transformer. The use of a gapped transformer in the high voltage tank will null the primary currents (up to 1.5 KVA) and the overload will allow operation to the full output rating of 3 KVA. When testing purely resistive loads, the unit will overload above 1500 VA of input power to the tank.

Using the Return Modes Grounded Return- With the output return in the grounded mode, the current meter reads all current to ground, internal and external to the test set. This current might include corona, surface tracking, and any shunt resistance. Guarded Return- With the output return in the guarded mode, the current meter will only read currents through the test sample.

Grounded Return Diagram

Guarded Return Diagram