Factors Effecting the Production

Slides:



Advertisements
Similar presentations
Producing an X-ray Exposure
Advertisements

Technical Aspects: the machine the image
Advanced Biomedical Imaging Lecture 3
Technique Guidance Systems
X-ray films are generally mad of an emulsion-gelatin containing radiation sensitive silver halide. with a flexible, blue tented base X-ray films are sensitive.
Line focus principle Heal effect Ratings Tube failure
 The panoramic unit is often used to cut down on the amount of radiation the patient is exposed too pared to a CMX. This technique is also utilized to.
Chapter 11 Prime Factors.
Formation Characteristics
4 Producing Quality Radiographs.
Quality Control in Diagnostic Radiology
Primary Exposure Factors IV
Chapter 18 Radiographic Exposure
Radiographic Quality Chapter 5.
Resident Physics Lectures
Chapter 7 Radiographic Image Formation and Exposure Factors.
Chapter 6 Control of Secondary and Scattered Radiation.
Control of Scatter Radiation Beam Restricting Devices
Dental X-ray Machine 118 Radiology.
Analyzing the Image Density. Density Overall blackening of the image.
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
Technical Artifacts and Errors
Veterinary Radiology Safety and Procedures. What is a radiograph? When an xray beam (a form of electromagnetic radiation) penetrates tissue to form a.
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. Chapter 8 Dental X-Ray Image Characteristics.
Basic quality control tests in medical radiography
Factors affecting the X-Ray output
Conventional and Computed Tomography
Quality Control Rad T 110.
Quality Control.
Ch. 2 – Anatomy of the X-ray Machine
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
About the 35mm Manual Film Camera Nickie Cardano Greyson Shane Per. 4.
Dr Mohamed El Safwany, MD.
Rad T 290 Generators. Generator Components control console  kVp adjust  mA adjust  time adjust transformer  high voltage (step up)  filament »low.
Prime Exposure Factors 1
Exposure Factors or Prime Factors
PRINCIPLES OF TECHNIQUE AND EXPOSURE
Radiographic Quality Visibility and Sharpness
Determining Radiation Intensity
Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and Hygienists, Ninth Edition Evelyn.
Stacy Kopso, M.Ed., R.T.(R)(M).  Xray photon loses energy and changes direction  Responsible for most of the scatter that fogs the image  Related to.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
Tube Exposure Factors Math Technique Contrast and Density
 Make and type of x-ray machine  Incoming line voltage  Kilovoltage  Milliamperage and exposure time  Focal film distance/source-imagine distance.
An early x-ray by Wilhem Rontgen
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
Quality Assurance in Dental Radiography
Exposure Factors or Prime Factors
Producing An Image RVT: Chapter 6. Learning Objectives: Chapter 6 Understand the 4 factors of radiographic exposure and how each impacts the production.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
Patient is placed between X-ray tube and silver halide film.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
Control of Scatter Radiation Beam Restricting Devices By Prof. Stelmark.
RADIATION PROTECTION 04/12/2016.
THE X-RAY UNIT THE BASICS.
Ch 36 Radiation Protection Design
Chapters 21 & 22.
THE X-RAY UNIT THE BASICS.
X-Radiation.
Stacy Kopso, M.Ed., RT(R)(M)
Exposure Factors Chapter 4
Resident Physics Lectures (Year 1)
Processing Radiographs
Resident Physics Lectures
Resident Physics Lectures (Year 1)
Radiation Protection in Fluoroscopy
Radiation Protection in Fluoroscopy
What makes a Quality Image
Artifacts and Errors.
Presentation transcript:

Factors Effecting the Production of Radiographs

The x – ray output test used to monitor the reproducibility of radiation output by a particular x –ray machine. A dosimeter is used to read the output. Now factors effecting quality control. a. Factors related to x –ray beam (exposure technique factors) which include: - 1. Kilovoltage peak (kVp): Kilovoltage is the tube current or flow of electrons across the tube. Inaccurate kVp calibration will affect contrast and to a lesser extent the density of resultant radiograph. 2. The half – value layer (HVL): Is determined by placing thin aluminum filters infront of the beam and recording the thickness of the beam and recording the thickness of aluminum in millimeters needed to reduce the exposure by half. The exposure timer regulates the length of time during which x –rays are generated. Exposure time has a major effect on beam quality and intensity and consequently on radiographic density so any defect in the timer  too dark or too light image production

3. Exposure time: can be checked electronically with a digital read out meter or mechanically with a spinning top. 4. Milliamperage (mA): Is responsible for the quantity and intensity of the x – ray beam and for the resultant density of the radiograph. 5. Focal spot size: It has a major effete on image sharpness, as an x –ray tube is used, the extreme temperature can cause the surface of the target to deteriorate as a result of pitting. This results in an increase in size of the effective focal spot to define small structures decreases, and focal spot size varies with changes in kVp and mA.

6. Beam alignment and collimation: Work together to expose a precise area of the patient. Unproductive irradiation of the patient occurs if the beam or the collimator or both are not aligned. If the x –ray the tube within the machine housing is not aligned with the aperture of the lead diaphragm where the x –rays exit the housing, significant cone – cutting will result. Collimation results in the final shape and size of the x –ray beam. The diameter of a beam at the end of a round collimator should not exceed 7cm (2.75inch). 7. Movement of the tube head: Caused by an unstable suspension arm can result in motion unsharpness of the radiographic image. Suspension arms most commonly are stabilized by hydraulic and coil spring dampeners. In most cases, there are easily adjustable after reference to the owner's manual. The foregoing quality control tests are not difficult to perform. A degree of mechanical ability and an assortment of equipment are necessary to carry out the tests. Testing should be done yearly, and all procedures and results documented in log book.

8. Tube film distance: The distance from the x –ray tube to the film greatly affects the intensity of radiation at the film position. This relationship is stated in the inverse square law; the exposure time is proportional to the square of the distance measured from tube to film and this formula is used when the kVp and mA must kept constant and exposure time and tube film distance need to be changed. T.F.D. have no affect on kVp but when T.F.D. change we have to make change in the exposure time and the mA. When there is greater distance between the tube and the object and smallest distance between the film and object it will give a proper density.

b. Factors related to object (absorbing media) This include two factors object thickness: that thicker the object the more radiation is required to get through the object to the film usually radiation is increased by increasing the mA and exposure time; also it is advisable to use higher kVp; higher kVp reduce the exposure time and minimize image blurring because of movement; also reduction of exposure time can be accomplished by increasing mA and/or film speed; the secondary radiation increased with the increasing of the object thickness. For the teeth and jaws we need about 10 – 15mA and kVp about 60-65 KVA. Objective Density: It is refereed to the weight per unit volume of the object. The density of the tissues being examined plays an important part in the creation of film fog due to secondary radiation. The soft tissues tend to produce more secondary radiation fog an a film then the hard tissue, this can compared by radiograph of a patients.

c. Factor related to film processing 1. Good darkroom. 2. Good equipment. 3. Good processing technique. 4. Good storage of the film. The temperature shouldn't exceed 68F0 and the time is about 4 1/2 minutes. If we have a higher temperature more than 68F0, we will have a short scale of contrast. If we have decrease low degree; the contrast will be decreased (long scale). If the time of processing decrease (processing time is less than 4 minutes), we will have less density, and if the time of processing. Is increased, we will have increased film fog. So any error in the steps of processing (developing, rising, fixing and washing) will give faulty film processing that effect the quality of radiograph. and for good storage of the film Film should stored in a dark cool place (like dark room). It should stored in steel or lead lined boxes to protect the film stray radiation. It should not exposed to chemicals or excessive humidity. It should be used before expiray date record an the film.