Revisiting the optimum PMT size for water-Cherenkov megaton detectors

Slides:



Advertisements
Similar presentations
Dante Nakazawa with Prof. Juan Collar
Advertisements

Large Area, Low Cost PMTs Neutrinos and Arms Control Workshop Paul Hink 6 February 2004 BURLE INDUSTRIES.
Picosecond Timing Workshop 18 November Sales meeting 2005 Discovering the Future.
for Fusion Power Monitoring
Jan 2009 U. Katz: Astroparticle Physics 1 What is KM3NeT – the Vision  Future cubic-kilometre sized neutrino telescope in the Mediterranean Sea  Exceeds.
6 April 2005Aussois, France BURLE INDUSTRIES Next Generation Large Area Low Cost PMT UNO Collaboration Robert Caracciolo and Richard Leclercq 6 April 2005.
Peter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute The HERA-B RICH counter.
Time-of-Flight at CDF Matthew Jones August 19, 2004.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Revisiting the optimum PMT size for water-Cherenkov megaton detectors
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
C. Joram CERN / PH International Scoping Study CERN Meeting September Development of spherical HPDs for a Water Cherenkov Detector (initiated by.
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
Scintillation Detectors
Prototype string for a km3 Baikal neutrino telescope Roma International Conference on Astroparticle Physics V.Aynutdinov, INR RAS for the Baikal Collaboration.
Copyright © Hamamatsu Photonics K.K. All Rights Reserved. Oct at NNN07 Workshop Hamamatsu Photonics Electron Tube Division Recent Progress in PMTs.
Hamamatsu R7525 HA: outer conductive coating with insulating sleeve CC: convex-concave window mm thick (standard plano-concave: 1mm center, 6.1.
B.K.Lubsandorzhiev, MSU 16 May Nuclear Photonics Methods in EAS Cherenkov Arrays Bayarto Lubsandorzhiev Institute for Nuclear Research RAS Moscow.
Latest developments in Hamamatsu Large Format PMTs
T. Sumiyoshi (TMU) 30, Nov del Carmen 1 Development of HPD (HAP D) Photon-detector for the Aerogel RICH Photon-detector for the Aerogel.
1 The X-HPD: Development of a large spherical hybrid photodetector A.Braem +, C. Joram +, J. Séguinot +, L. Pierre *, P. Lavoute * + CERN, Geneva (CH)
Large Photodetector Developments in Europe
TOF for ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Department of Radiology UNIVERSITY OF PENNSYLVANIA 1 Investigation of LaBr 3 Detector Timing Resolution A.Kuhn 1, S. Surti 1, K.S. Shah 2, and J.S. Karp.
Founded in 1906 by Nahum Kolmanok; 1913 – merging with bulb factory “Light”. As a result, “Russian electric lamp” manufacture was established; 1921 –
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
NuFact 05 Revisiting the optimum PMT size for water-Cherenkov megaton detectors Esso Flyckt, Christophe Fontaine, Pascal Lavoute and Carole Marmonier Photonis,
SiW ECAL Technological Prototype Test beam results Thibault Frisson (LAL, Orsay) on behalf of the CALICE collaboration.
Developments in hemispherical tubes for underwater Neutrinos detection. Bruno Combettes PHOTONIS Group Product Manager PHOTONIS-Brive, France CPPM Meeting.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
Andy Cormack Sensor Development Director Graham Sperrin European Sales Manager ET Enterprises Limited 45 Riverside Way Uxbridge UB8 2YF United Kingdom.
Hyper-Kamiokande project and R&D status Hyper-K project Motivation Detector Physics potential study photo-sensor development Summary Kamioka.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
8 April 2005Aussois, France BURLE INDUSTRIES Recent Photomultiplier and Device Developments NNN05 Robert Caracciolo 8 April 2005 BURLE INDUSTRIES.
Tunka Experiment: Towards 1км 2 EAS Cherenkov Array B.K.Lubsandorzhiev for TUNKA Collaboration.
EUROnu WP5 Detector Costing EuroNu Annual General Meeting, Strasbourg 3 June 2010 Paul Soler.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
October 2002Sienna, JL. Faure, DAPNIA/SPP In 8th Topical Seminar on Innovative Particle and Radiation Detectors Jean-louis Faure CEA-DAPNIA-SPP Progress.
Characterization of the QUartz Photon Intensifying Detector (QUPID) Artin Teymourian UCLA Dark Matter Group Dept. of Physics and Astronomy.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
K.Wyllie, CERNIWORID 2004 Readout of the LHCb pixel hybrid photon detectors Ken Wyllie on behalf of the LHCb collaboration and industrial partners The.
M.Teshima (MPP, U-Tokyo) M.Pimenta (LIP) T.Schweizer (MPP)
1 Development of a Large Area Photodetector with a Fast Phosphor Anode Toru Iijima Kobayashi-Maskawa Institute Nagoya University Open Meeting for the Hyper-Kamiokande.
PROJECT X PHYSICS STUDY WORKSHOP (PXPS 2012) Working Group on Time of Flight Conveners: Mike Albrow (FNAL) & Bob Wagner (ANL) New directions in fast timing:
P. Lecoq CERN2 February ENVISION WP2 Meeting CERN Group contribution to ENVISION WP2 Paul Lecoq CERN, Geneva.
 13 Readout Electronics A First Look 28-Jan-2004.
Efficiency, Dark noise, and Baseline fluctuations with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010.
Update on Electronics Activities
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Photon Detector for AFP
At HSTD8 in The Special Session In Honour Of Prof. Takashi Ohsugi
LHAASO-WCDA: Design & Performance
X-HPD OM R&D KM3NeT OM meeting Genova, April 9-11, 2008
Gamma Camera.
A First Look J. Pilcher 12-Mar-2004
Large Photodetector Developments in Europe
Conceptual design of TOF and beam test results
X. -HPD Optical Module R&D for KM3NeT (
Department of Physics and Astronomy,
Measured baseline fluctuations and dark counts with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010.
Scintillation Counter
Recent Progress in Large Format PMTs
Oct 10, 2018 Muhammad Qasim Abdul Wali Khan University, Department of Physics, Mardan, Pakistan by.
Development of hybrid photomultiplier for Hyper-Kamiokande
New photon detector R&D for Megaton water Cherencov detector
Status Report on MCP PET Simulation
Presentation transcript:

Revisiting the optimum PMT size for water-Cherenkov megaton detectors Esso Flyckt, Christophe Fontaine, Pascal Lavoute and Carole Marmonier Photonis, Brive, France NNN05 workshop Aussois 2005-04-08 NNN05-Photonis

Overview PHOTONIS Physics is challenging Traditional PMTs Optimal size <=> cost Capacity & investments Sub-conclusions Discussion R&D prospects NNN05-Photonis

Brive RODEN BRIVE 1998 PHOTONIS 2005 PHOTONIS-DEP 1937 PHILIPS BRIVE 1963 HYPERELEC 1986 RTC Compelec 1990 PHILIPS COMPONENTS 1992 PHOTONICS 1998 PHOTONIS 2005 PHOTONIS-DEP Brive NNN05-Photonis

PHOTONIS Photomultipliers Image intensifiers Streak tubes Microchannel plates Single-channel electron multipliers Neutron detectors NNN05-Photonis

PMTs Nuclear medicine (~80%) Analytics/industrial (~10%) gamma cameras PET scanners Analytics/industrial (~10%) Physics (~10%) NNN05-Photonis

H.E.S.S. in Namibia (very-low after-pulse PMT) NNN05-Photonis

Veritas in Arizona NNN05-Photonis

Auger in Argentina NNN05-Photonis

Traditional PMTs Hemispherical 5“, 8“, 9“, 10.6“, 12“, 15“ NNN05-Photonis

Very many PMTs Example: UNO >50,000x 20“ PMT size <=> cost Sensitivity Embedded inside water volume Timing SE pulse-height resolution Granularity NNN05-Photonis

PMT size <=> cost Diameter 20“ <=> (20“)17“ <=> 12“ projected area 1660 1450 615 cm² QE(typ) 20 20 24 % CE 60 60 70 % Cost 2500 2500 800 € Cost/cm² per useful PEU= cost/(cm²xQExCE) 12.6 14.4 7.7 €/PEU/cm² NNN05-Photonis

Timing-Weight Size 20“ 17“ 12“ Rise time (ns) Jitter (ns) 10 5.5 6 3.4 2.4 Weight (kg) 8 8 2.2 NNN05-Photonis

Single-electron resolution Need good P/V for exact gain calibration: 20“ difficult? (P/V = 1.1 - 1.7:1) 17“ P/V = 1.5 - 2.5:1 (reality better) 12“ P/V = 1.5 - 2.3:1 (reality better) NNN05-Photonis

Quantities and total cost 20“ 50,000 x € 2500 = € 125M 17“ 57,200 x € 2500 = € 143M 12“ 135,000 x € 800 = € 108M NNN05-Photonis

New pump capacity needed? Delivery over 6 years 300 working days/year 20“ tube 50,000/6/300 => 28 good tubes x yield 0.7 = 40 starts/day (1 start/pump/day) => 40 pumps ( € 7M or so) 12“ tube 135,000/6/300 => 75 good tubes x yield 0.7 = 110 starts/day. A multi-array computerised pump at Photonis handles 20 starts/day => 6 pumps ( € 2M or so) NNN05-Photonis

+ Sub-conclusions 12“ seems much better than 20“/17“ cost per useful photoelectron & total PMT cost timing single-electron resolution (17“ equal) granularity weight and handling implosion risk investments and start-up NNN05-Photonis

- Sub-conclusions cost of more cables and electronics 12“ tubes may also need a shield at 60 m depth (or thicker glass?) NNN05-Photonis

Discussion The 12“ tube is a cost-optimum for Photonis pumping systems - maybe other cost-optima in 8“ - 15“ for other suppliers? Can be made by at least 4 suppliers - without major R&D! Photonis is willing, able and prepared up to 15“ However, non-industry investments needed! NNN05-Photonis

Optimise! Cost/cm² per useful PEU= cost/(cm²xQExCE) NNN05-Photonis

Invest in QE now! Instead of investing € 7M (or so) for 20“ it is better to invest € 2M (or so) for 12“ and another € 0.5M in getting the QE up to > 30 % Photonis has such a QE programme Characterisation with French institutes NNN05-Photonis

„Smart“ PMTs so far „smart“ => PHR => elimination of single PE noise (for DUMANDs) Patented by Philips (Photonis) Copied (faster mushrom shape) by INR, Moscow, into the „QUASAR“ Philips (spherical) NNN05-Photonis

anode target was YSO single-crystal at +25-30 kV => photocathode at ground potential! partly sensitive from the back NNN05-Photonis

Pulse-height resolution S/N 8 & 10 deployed in Lake Baikal NNN05-Photonis

Status „smart“ PMTs Philips/Photonis made ~ 30; invested 1M €! 200 QUASARs operating for many years in Lake Baikal => proof of concept as to life time! No ongoing production! Could be made (and improved) again! NNN05-Photonis

Possible „smart“ PMTs Reproduce and improve former tubes Redesign (target) Better scintillator (LSO, ZnO:Ga, ...) Si diode/Si diode array APD/APD array Multianode multiplier Quadrant PMT (inside/outside) ?? NNN05-Photonis

On-going R&D „smart“ 8 => 12“ tubes with: electron-bombarded scintillator in a preamplifier tube, read-out by a small, fast PMT electron-bombarded Si diode as the anode Both will resolve 1, 2, 3, several photoelectrons but - need to stand > 15 - 20 kV Is such „smartness“ worth a factor 2-3 in cost? NNN05-Photonis

Photonis has all the technical capability needed Photonis has all the technical capability needed! R&D cooperation: detailed & intensive talks are going on with the MEMPHYS collaboration to define a balanced programme Workshop planned in the spring NNN05-Photonis

Questions? NNN05-Photonis