Quick Reference Troubleshooting Common Service Components PFE29 BM Freezer
New GE French Door refrigerator Door Hinge Guide Leveling Guide
Door Hinge Alignment for re-install Purple mark indicator orientated towards alignment arrow to reinstall door at 90° to case front Hinge cam parallel to alignment arrow is correct to reinstall door at 90° to case front Purple dot facing arrow correct NOTE: An improper door installation could result in the door “popping” open instead of “pulling” closed Parallel to arrow correct Hinge cam perpendicular to alignment arrow is incorrect Perpendicular to arrow incorrect
Freezer Defrost Heater ~ Service mode: (Water-Crushed-Cubed) ~ 00 60 (In Control Display) ~ J1 Pin 3 orange- ( neutral ) ~ J1 Pin 4 FZ defrost heater ~ 120 VAC ~ 33 Ohms 3 4 J1-3
Fresh Food Defrost Heater 2 3 ~ Service mode: (Water-Crushed-Cubed) ~ 00 53 (In Control Display) ~ J1 Pin 3 orange- ( neutral ) ~ J2 Pin 2 FF defrost heater ~ 120 VAC ~ 85 Ohms J1-3
Fresh Food Fan ~ Service mode: (Water-Crushed-Cubed) RPM PWM Supply voltage DC Common +12 VDC ~ Service mode: (Water-Crushed-Cubed) ~ 00 47 (Displayed) ~ J6 Pin 2 +12 VDC ~ J6 Pin 4 - DC Common (*Use for all tests) ~ J6 Pin 6 4 to 12 VDC (3 speed) ~ J6 Pin 8 92 < 112 Hz ( Red * dot indicates a wire in terminal)
Freezer Fan ~ Service mode: (Water-Crushed-Cubed) ~ 00 48 (Displayed) +12 VDC DC Common PWM Supply voltage RPM ~ Service mode: (Water-Crushed-Cubed) ~ 00 48 (Displayed) ~ J8 Pin 1 +12 VDC ~ J8 Pin 3 - DC Common (*Use for all tests) ~ J8 Pin 5 4 to 12 VDC (3 speed) ~ J8 Pin 7 92 < 112 Hz 8 -> 1
Ice Box Fan ~ Service mode: (Water-Crushed-Cubed) ~ 00 47 (Displayed) +12 VDC DC Common PWM Supply voltage RPM ~ Service mode: (Water-Crushed-Cubed) ~ 00 47 (Displayed) ~ J8 Pin 2 +12 VDC ~ J8 Pin 4 - DC Common (*Use for all tests) ~ J8 Pin 6 4 to 12 VDC (3 speed) ~ J8 Pin 8 92 < 112 Hz 8 -> 1
Thermistors Service mode: 00 24 FF Cabinet 00 26 FF Evap. 00 27 FZ Cabinet 00 28 FZ Evap. (Displays actual temps.) J11 J10 (Red * dot indicates a wire in terminal)
Icemaker’s Door Board Service mode: ( Water – Crushed – Cubed) 00 66 DB I/M Rake Motor Turned On / 120VAC Aqua & Orange 00 88 DB I/M Mold Heater Turned On / 120VAC Purple & Orange Door Board Mold Heater Mold Heater Rake Motor Rake Motor DC AC