P17082 Biomechanical Elbow Model Detailed Design

Slides:



Advertisements
Similar presentations
Muscle Biomechanics.
Advertisements

Routed Systems Presented by: Bassam Najar, Design Engineer Butler International Inc.
Integrated Natural Science
Testing Variables Students will manipulate variables of a pendulum; draw conclusions from experimentation with pendulums Why should you test only one variable.
Artificial Limb Project By Casey Dill. Mission Statement This project will improve upon existing plans for an artificial arm with the same capabilities.
P10511: Miniaturization of Xerography Derek Meinke (ME, PM) Matthew Liff (ME) Tony Zhang (EE) Zaw Htoo (ISE)
Christian Seemayer Rob Proetti Tim DeBellis Tim Giguere Will Kelly.
MSD-I Project Review Modular Motion Tracking Sensors 1.
LFTB Proprietary Information 1 Fuser test bed ™ R I T MSD1 Project Review February 22, 2007 Fuser Test Bed P07501 IE TEAM Justin McMillan – Project Lead.
Software Engineering CSE470: Requirements Analysis 1 Requirements Analysis Defining the WHAT.
CAD/CAM Design Process and the role of CAD. Design Process Engineering and manufacturing together form largest single economic activity of western civilization.
MSD-II Project Review Modular Motion Tracking Sensors 1.
ERGONOMICS :: TRAIN-THE-TRAINER PROGRAM :: TASK ANALYSIS TOOLS Task Analysis Tools.
Safe Spot ME 4182 Final Presentation April 26 th, 2006 J.J. Couvillion - Elisha Mellitz - Manish Patel - Nick Roberts - Drew Bartlett.
EVA Magician for Injection Molding of EVA Shoe Soles.
Guide Workshop Tuesday, August 19, Agenda I.MSD Fall 14 Logistics Werth –45 minutes 1.Class Schedule high level 2.Grading Period Highlights 3.MSD.
S/W Project Management
SAFETY PLAY OF THE WEEK Ergonomics in the Work Place.
D-R Compressor Cell RIT Senior Design Team P13458 Systems Design Review.
Preliminary Detailed Design Review P15080 Flow Culture System November 13, 2014.
Motor Assisted Wheelchair Design Review 09/10/15.
Copyright Catherine M. Burns1 SEATING, CTD, MUSCLE FATIGUE.
P  Customer Dr. Schrlau  Team Jacob Bertani Bridget Lally Avash Joshi Nick Matson Keith Slusser  Guide Bill Nowak.
Project Active Vibration Cancellation. The Team NameDisciplineRole Kaitlin PeranskiIndustrial and SystemsProject Leader/ Edge Updating Jeremy BerkeElectricalScribe.
Team Churro: Sharon Grimshaw, Maggie Su, Louis Yi, Morgan Zheng.
MSD Total Supplier Performance and Inventory Control Keleigh Bicknell, William Darlington, Alex Resnick, Brian Woodard.
P16453 Subsystem Design Loading, Measurement, Control, and Test of a Journal Bearing Test Platform Kris Kidder | John Dolan | Shay Stanistreet | Anthony.
E-NABLE Hand Test Rig P16061 David Schwartz, Tia Parks, Shannon Barry, Samantha Mason, Charles Rumfola.
P – , TOW TANK FOR TETHERED HYDROFOIL TEAM MEMBERS: Hope Alm (ME)Tim Buckner (ME) William Lentlie (ME) Andres Santizo Matheu (ISE) Shauna.
E-NABLE Hand Test Rig P16061 David Schwartz, Tia Parks, Shannon Barry, Samantha Mason, Charles Rumfola.
Unit 17: SDLC. Systems Development Life Cycle Five Major Phases Plus Documentation throughout Plus Evaluation…
P16680: AATech Universal Oil and Bag System System Design Review 9/29/15.
Muscular Strength and Endurance
Electrophotographic Cascade Development Apparatus Team 15503:Zach Foggetti (ME) Dalton Mead (ME) Bridget Kearney (EE) Ruishi Shen (ISE) Tom Wossner (ME)
Strength. Strength Strength is the maximum amount of force a muscle, or group of muscles, can exert in a single effort The three main types of strength.
Complete Design & Gate Review. Complete Design Detailed Design Review (DDR) 1.“High and medium technical risk” areas –Design Review (Prelim-DDR): standard.
What has been accomplished at the end of MSD 1 & 2?
Motor Assisted Wheelchair Design Review 10/01/15.
Author name here for Edited books chapter Assessing Balance and Designing Balance Programs chapter.
COMPONENTS OF FITNESS & FITNESS TESTING PHYSICAL EDUCATION MRS. MANNE.
Dillon: CSE470: ANALYSIS1 Requirements l Specify functionality »model objects and resources »model behavior l Specify data interfaces »type, quantity,
Strength Strength is the maximum amount of force a muscle, or group of muscles, can exert in a single effort The three main types of strength are:  Static.
Joseph Ferrara Team Lead (ME) Joseph ChurchDesign Engineer (ME) Joshua Van Hook LabView Engineer (EE) Jamie Jackson Electronics (EE) Joelle Kirsch Project.
The Four-legged Water Walker
MESA USA Prosthetic Arm Challenge 2.1- Revisions
Project life span.
Systems Analysis and Design
P17082 Biomechanical Elbow Model Preliminary Detailed Design
The Project IENG 248 Lab.
P08002-Automated Parallel Bars
P17082 Biomechanical Elbow Model
P17082 Biomechanical Elbow Model Build and Test Review
Angel Hambrecht, Justin Kibler, Nate Watts, and Maxine Laroche
P17082 Biomechanical Elbow Model Final Presentation
Systems Design Review : Heart Pump and Circulatory System
P17082 Biomechanical Elbow Model Build and Test Prep
P17082 Biomechanics Elbow Model
P17082 Integrated System Build & Test Review
SENIOR DESIGN PROJECT P08455
Final Status Update P09006 – Upper Extremity Exerciser
Mechanical Bioreactor
Team Tabletop Platen Press
Engineering Technology Program
Detailed Design Review (Phase 4)
Detailed Design Presentation
Mechanical Bioreactor Detailed Design Review
Detailed Design Review Solar Thermal Water Heater
Detailed Design Review: P18001
P19045 Essential Tremor Test Rig II Final Review April 7th, 2019
Preliminary Detailed Design Review: P18001
Presentation transcript:

P17082 Biomechanical Elbow Model Detailed Design Maria Romero-Creel, Shannon Keenan, Chris Harley, Amanda Cook

Agenda Team Vision Benchmarking Prototyping Manufacturing Processes Bill of Materials Test Plans Risk Assessment Action Completion Plans and Schedule Individual Three Week Plans Concerns and Issues

Team Vision The goals of this phase and design review were to have bone designs appropriate for a functional prototype and decide on the production methods for the model. Plans: Correct previous 3D models & drawings. 3D Print Working Prototype Update Testing Plans   What was done: 3 different prototypes were 3D printed in different sizes and densities Assessed various possible methods of production of completed models. Evaluated the engineering requirements, test plans, risks, and costs of the designed system. Determined challenges of the design, how successful designs and subsystems will be evaluated, and identifying sources and triggers for risk mitigation.

Functional Decomposition

Benchmarking - Updated

Prototyping – Preliminary Detailed Design A model of the system will be 3D printed using PLA filament to assess proper functionality. Primary Design Radius Length  23.2 cm Shape Approximated with 3D printed model Max strain 1 cm Ulna  25.15 cm Humerus  32.05 cm Muscles Force Can be modeled with string as a force Attachment Points Can be printed into the bone for reputably accurate models

First Prototype Scaled : 1/3 of the real size PLA Filament What was right? - Length of bones was accurate. What was wrong? - Joints didn’t match perfectly. - Spacers for goniometer were missing. - Guide channel for string on top of humerus was needed. - Not strong enough. - Printed using small 3D printer (resolution not accurate)

Second Prototype Scaled : 1/3 of the real size PLA Filament What was right? - Joints fit better. - Spacers were appropriate for desired use - Guide channel on humerus printed well. What was wrong? - Size. - Missing holes for strings to go through

Final Prototype – Part Models

Final Prototype Real Size PETG Filament  Better resolution using Gigabot What was right? - Joints fit well. - Spacers were appropriate for desired use - Resolution was good. - Easy to melt holes into model. - Fits well with PASCO stand. Concerns - Strength of the bones. - Complexity of model for manufacturing.

Casting vs. 3D Printing Casting 3D Printing Pros: Better resolution High initial cost, but low cost after casts are done Better strength of material Cons: Cost of molds Difficult with complex models 3D Printing Pros: Low cost Easy Access to Construct Can continue to be modified throughout. Cons: Lower resolution Longer lead time Strength Concerns

Assessing Strength of 3D Printing Parts Printing using different densities

Bill of Materials (BOM)

Test Plans – Engineering Requirements Overview

Test Plans ER1,2,3 – Static Force of Muscle A, B, and C. Test - Attach load cell to break in muscle string, hang 250g mass from hand hook, wait for arm to lower under the weight and settle, then get read out from Capstone. Validity- Force achieved at rest must match accepted anatomical value. ER4 – Angles at each position Test - With each muscle attached and load cells strung, and the goniometer attached and reading out to Capstone, the arm is bent at the elbow and moved through the available range of motion. Validity- readout must show that the arm can move from approximately 0o and 180o.   ER5 – Max Load Test -Hang a load of 500g from the hand hook while holding the lower arm up to the upper arm so that the angle of the elbow is approximately 0­o. release the lower arm and allow the weight and lower arm to fall. Validity- The arm must be able to fall and stop while still holding the weight, staying upright and stable and produce steady force and angle change graphs / tables through Capstone. There should be no bending or material failure in a valid case, and the entire base must still be resting on the tabletop.

Test Plans ER6- Muscle Attachment Position Test - With load cells in place, no weights, and the lower arm resting so that the angle of the elbow is approximately 90o, measure the angles of the muscles with the bones and the distance of the muscle attachment to the bones. Validity – Both values must be within ±5%of the average adult. ER7,8 – Deviation and Possible Positions Test - Set the model in each possible position with the 250g weight. For each position (supinated wrist, pronated wrist, flexed elbow), allow the device to sit, with no contact or extra support from an outside object for 1 minute, measure deviation. Validity – The position set by the user must not deviate by more than ±1cm during the wait period.   ER9- Time Required for Assembly Test - Begin with an unassembled device. Start a timer and begin assembly, including the addition of base structure strings, load cells, goniometer, and arm straps. Include all hardware cables necessary for data acquisition (load cells, goniometer). Validity – The full assembly takes approximately 20 minutes or less to assemble and can support a 250g weight from the hand hook upon completion.

Risk Assessment

Action Completion Systems Design Action Item Progress Finish Solidworks models of the bones and joints – 100% Print multiple revisions of bones and joints at various scales for updating the models and visualizing any potential issues, ending with the prototype prints from the final models – 100% Communicate with the Construct @ RIT for prints & design input – 100% Make manual edits to bones and joints – 80% Investigate casting materials & options – 80% Obtain base for structure stand – 100% Update Bill of materials – 100% Update Engineering Requirements – 100% Update Risk Assessment – 100% Update drawings – 100% Update Test Plans – 100% Address immediate purchasing needs – 100% Test ‘muscle’ fit – 50% Assembly – 80%

Individual Contributions Print revisions of bones at multiple scales – All Consider placement of goniometer and force gauges for data acquisition - All Make adjustments to Solidworks bone and joint models – Chris & Amanda Communicate with the Construct @ RIT - Maria Make manual edits to bones and joints – All Investigate casting materials & options – Maria Obtain base for structure stand – Amanda Update Bill of materials – Amanda Update Engineering Requirements – Shannon Update Risk Assessment – Chris Update drawings - Chris & Amanda Update Test Plans – Shannon Test ‘muscle’ fit – All Address immediate purchasing needs – Amanda Assembly - All

Plans & Schedule Project Plan Highlights 1 Project Plan Highlights Printing bones using a higher density. Assemble model. Apply test plans on prototype.

Individual Three Week Plan Amanda: Purchasing / Budget Remain active in test plans 3D CAD Models – Ensure accuracy and help update models Continue to consult with SME to ensure physiological accuracy of model. Shannon: Run test plans on preliminary prototype (3 hours, Week 1) Recreate and address any concerns with base subsystems (3 hours, Week 1) Begin printing next set of bones at full density (5 hours, Weeks 2) Add muscle subsystems to prototype (2 hours, Week 2)

Individual Three Week Plan Chris: Finish the final tweaks to the cad models of the bones. (1 hour) Assess our prototype and see if there are any last-minute changes that seem necessary (3 hours) Ensure that all materials are ordered and finalized (2 hours) Do mock labs with the prototype and stress test the prototype. (5 – 6 hours) Test the full-strength parts during the first week of MSD II (5 hours) Maria: Consult SMEs and Customer and decide on casting vs. 3D printing. Participate in testing of prototype. Participate in building and assessing feasibility of model. Consult SMEs and help ensure physiological accuracy of model.

Concerns and Issues Hinge Concerns Budget – Depending on casting or 3D printing Strength of bones – Material

Questions or Suggestions?