Laboratory Quality Control

Slides:



Advertisements
Similar presentations
Errors in Chemical Analyses: Assessing the Quality of Results
Advertisements

Control of Analytical Variables Dr. Roula Hamid MSc Clin Biochem Central Puplic Health Laboratory QC Chemistry.
Quality Assurance Programmes for Laboratory Testing - An Overview Elizabeth M. Dax National Serology Reference Laboratory, Australia Elizabeth.
Dr Samah Kotb Lecturer of Biochemistry 1 CLS 432 Dr. Samah Kotb Nasr El-deen Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Nasr.
Laboratory Quality Control
Quality Assurance.
How Science Works Glossary AS Level. Accuracy An accurate measurement is one which is close to the true value.
Internal Quality Control (QC) for Medical Laboratories: An introduction Dr. Otto Panagiotakis and Dr. Alexander Haliassos ESEAP – Greek Proficiency Testing.
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
InterQC Delivering Simplicity in the Quality Control Management for your Laboratory Developed by Vitro.
Control charts Pharos University. An internal system for quality control is needed to ensure that valid data continue to be produced. This implies that.
Quality Assurance in Haematology
Quality Assurance in the clinical laboratory
Quality Assurance / Quality Control
Chemometrics Method comparison
Method Comparison A method comparison is done when: A lab is considering performing an assay they have not performed previously or Performing an assay.
Unit #7 - Basic Quality Control for the Clinical Laboratory
Quality Assurance.
Quality Assessment 2 Quality Control.
V. Rouillard  Introduction to measurement and statistical analysis ASSESSING EXPERIMENTAL DATA : ERRORS Remember: no measurement is perfect – errors.
ABC of Quality Control A problem based approach RT ERASMUS NHLS / FACULTY OF HEALTH SCIENCES, UNIVERSITY OF STELLENBOSCH 20th July, 2007, Bela Bela.
Automated CBC Parameters
Quality Control Lecture 5
Laboratory QA/QC An Overview.
TO ERR IS HUMAN ……. We detest it. We avoid even talking about it. ERRORS.
Why do we need to do it? What are the basic tools?
QC THE MULTIRULE INTERPRETATION
Laboratory Quality Control An Overview. Definitions (1) Quality Control - QC refers to the measures that must be included during each assay run to verify.
Storage, stocktaking and ordering supplies 1www.forum.advetresearch.com.
An Overview. Definitions (1)  Quality Control - QC refers to the measures that must be included during each assay run to verify that the test is working.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Application of Westgard multi rules in medical laboratories
Errors. Random Errors A random error is due to the effects of uncontrolled variables. These exhibit no pattern. These errors can cause measurements to.
Quality Control Internal QC External QC. -Monitors a test's method precision and analytical bias. -Preparation of quality control samples and their interpretation.
L ABORATORY Q UALITY C ONTROL. INTRODUCTION _A major role of the clinical laboratory is the measurement of substances in body fluids or tissues for the.
 Remember Chemistry panel Quality Control:-  In a medical laboratory, it is a statistical process used to monitor and evaluate the analytical process.
Westgard Multirule System
 Routine viral diagnostics: indirect and direct detection of viruses. ◦ Indirect detection: serological tests; ◦ Direct detection:  Viral antigens;
UNCERTAINTY OF MEASUREMENT Andrew Pascall Technical Director Integral Laboratories (Pty) Ltd
Diagnostic clinical chemistry
Veterinary Practice Laboratory Unit 1 Chapter 5 Quality Control and Record Keeping Copyright © 2015 by Mosby, an imprint of Elsevier Inc. All rights reserved.
Uncertainties in Measurement Laboratory investigations involve taking measurements of physical quantities. All measurements will involve some degree of.
Quality Assurance.
Quality Assessment.
Lesson 1-9 Quality Assessment.
Laboratory Quality Control
Pakistan Society of Chemical Pathologists Zoom Series of Lectures ZT 25. Quality Management 2 Brig Aamir Ijaz MCPS, FCPS, FRCP (Edin), MCPS-HPE HOD.
SUR-2250 Error Theory.
Surveying 1 / Dr. Najeh Tamim
Unit #6 - Basic Quality Control for the Clinical Laboratory
Pakistan Society Of Chemical Pathologists Zoom Series of Lectures ZT 24. Quality Managent 1 Brig Aamir Ijaz MCPS, FCPS, FRCP (Edin), MCPS-HPE HOD and.
Quality Assurance in the clinical laboratory
Westgard rules.
1 2 3 INDIAN INSTITUTE OF TECHNOLOGY ROORKEE PROJECT REPORT 2016
INTERNAL QUALITY CONTROL
Hematology 425 Quality Assurance
Quality Assurance: Pay Factors and Dispute Resolution
Practical clinical chemistry
Quality Control (2) Lecture 6
Process control in Hematology section
Choice of Methods and Instruments
Process Capability.
Quality Control Barbara Weberman MT(ASCP)
Introduction To Medical Technology
Quality Control Lecture 3
▪Internal quality control:
Westgard rules 12s rule: the run is accepted when both control results are within 2 SD limits from the mean value 13s rule: the run is considered out.
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Westgard rules Dr Ahmed Aboamer MD in Clinical pathology.
Presentation transcript:

Laboratory Quality Control An Overview

Definitions (1) Quality Control - QC refers to the measures that must be included during each assay run to verify that the test is working properly. Quality Assurance - QA is defined as the overall program that ensures that the final results reported by the laboratory are correct. “The aim of quality control is simply to ensure that the results generated by the test are correct. However, quality assurance is concerned with much more: that the right test is carried out on the right specimen, and that the right result and right interpretation is delivered to the right person at the right time”

Definitions (2) Quality Assessment - quality assessment (also known as proficiency testing) is a means to determine the quality of the results generated by the laboratory. Quality assessment is a challenge to the effectiveness of the QA and QC programs. Quality Assessment may be external or internal, examples of external programs include NEQAS, HKMTA, and Q-probes.

Variables that affect the quality of results The educational background and training of the laboratory personnel The condition of the specimens The controls used in the test runs Reagents Equipment The interpretation of the results The transcription of results The reporting of results

Errors in measurement True value - this is an ideal concept which cannot be achieved. Accepted true value - the value approximating the true value, the difference between the two values is negligible. Error - the discrepancy between the result of a measurement and the true (or accepted true value).

Sources of error Input data required - such as standards used, calibration values, and values of physical constants. Inherent characteristics of the quantity being measured - e.g. CFT and HAI titre. Instruments used - accuracy, repeatability. Observer fallibility - reading errors, blunders, equipment selection, analysis and computation errors. Environment - any external influences affecting the measurement. Theory assumed - validity of mathematical methods and approximations.

Random Error An error which varies in an unpredictable manner, in magnitude and sign, when a large number of measurements of the same quantity are made under effectively identical conditions. Random errors create a characteristic spread of results for any test method and cannot be accounted for by applying corrections. Random errors are difficult to eliminate but repetition reduces the influences of random errors. Examples of random errors include errors in pipetting and changes in incubation period. Random errors can be minimized by training, supervision and adherence to standard operating procedures.

Random Errors

Systematic Error An error which, in the course of a number of measurements of the same value of a given quantity, remains constant when measurements are made under the same conditions, or varies according to a definite law when conditions change. Systematic errors create a characteristic bias in the test results and can be accounted for by applying a correction. Systematic errors may be induced by factors such as variations in incubation temperature, blockage of plate washer, change in the reagent batch or modifications in testing method.

Systematic Errors

Internal Quality Control Program for Serological Testing An internal quality control program depend on the use of internal quality control (IQC) specimens, Shewhart Control Charts, and the use of statistical methods for interpretation. Internal Quality Control Specimens IQC specimens comprises either (1) in-house patient sera (single or pooled clinical samples), or (2) international serum standards with values within each clinically significant ranges.

Shewhart Control Charts A Shewhart Control Chart depend on the use of IQC specimens and is developed in the following manner:- Put up the IQC specimen for at least 20 or more assay runs and record down the O.D./cut-off value or antibody titre (whichever is applicable). Calculate the mean and standard deviations (s.d.) Make a plot with the assay run on the x-axis, and O.D./cut-off or antibody titre on the y axis. Draw the following lines across the y-axis: mean, -3, -2, -2, 1, 2, and 3 s.d. Plot the O.D./cut-off obtained for the IQC specimen for subsequent assay runs Major events such as changes in the batch no. of the kit and instruments used should be recorded on the chart.

Westgard rules The formulation of Westgard rules were based on statistical methods. Westgard rules are commonly used to analyse data in Shewhart control charts. Westgard rules are used to define specific performance limits for a particular assay and can be use to detect both random and systematic errors. There are six commonly used Westgard rules of which three are warning rules and the other three mandatory rules. The violation of warning rules should trigger a review of test procedures, reagent performance and equipment calibration. The violation of mandatory rules should result in the rejection of the results obtained with patients’ serum samples in that assay.

Shewhart Chart Antibody Units Assay Run +3 sd +2 sd +1 sd Target value -1 sd -2 sd -3 sd Assay Run VZV IgG ELISA: Target Value = 49 U/ml

Warning rules Warning 12SD : It is violated if the IQC value exceeds the mean by 2SD. It is an event likely to occur normally in less than 5% of cases. Warning 22SD : It detects systematic errors and is violated when two consecutive IQC values exceed the mean on the same side of the mean by 2SD. Warning 41SD : It is violated if four consecutive IQC values exceed the same limit (mean  1SD) and this may indicate the need to perform instrument maintenance or reagent calibration.

Mandatory rules Mandatory 13SD : It is violated when the IQC value exceeds the mean by 3SD. The assay run is regarded as out of control. Mandatory R4SD : It is only applied when the IQC is tested in duplicate. This rule is violated when the difference in SD between the duplicates exceeds 4SD. Mandatory 10x : This rule is violated when the last 10 consecutive IQC values are on the same side of the mean or target value.

Westgard Rules: 1 3SD Antibody Units Assay Run Target value -1 sd -2 sd -3 sd Assay Run VZV IgG ELISA: Target Value = 49 U/ml

Westgard Rules: 10X Antibody Units Assay Run +3 sd +2 sd +1 sd Target value -1 sd -2 sd -3 sd Assay Run VZV IgG ELISA: Target Value = 49 U/ml

Follow-up action in the event of a violation There are three options as to the action to be taken in the event of a violation of a Westgard rule: Accept the test run in its entirety - this usually applies when only a warning rule is violated. Reject the whole test run - this applies only when a mandatory rule is violated. Enlarge the greyzone and thus re-test range for that particular assay run - this option can be considered in the event of a violation of either a warning or mandatory rule.

Accreditation of Pathology Laboratories There is a movement towards the accreditation of medical testing laboratories worldwide. Accreditation is an external audit of an applicant department’s organization and quality assurance program. Examples of accreditation authorities include the CPA (College of American Pathologists) in the U.S., CPA (Clinical Pathology Accreditation) in the UK, NATA in Australia. ISO 15189 is used as the standard for all accreditation bodies in order to provide uniformity of standards and cross-recognition.