Characterization,calibration and traceability for lunar observation

Slides:



Advertisements
Similar presentations
Brown Bag Lunch Lecture ABI Calibration
Advertisements

Developing the VIIRS/DNB Lunar Reflectance Product Steve Miller Updated: 27 July 2012.
ASIC3 WorkshopLandsdowne, VA May 16-18, 2006 J. Harder Page 1 Calibration Status of the Solar Irradiance Monitor (SIM) : The Present and the Future Jerald.
Spectroscopy of Stratospheric Molecular O3
NOAA Research and Operations Marine Optical Buoy Design Review July 18-19, 2006 Plan for calibration and maintenance of AHAB Uncertainty Budget: Laboratory.
Sergey Mekhontsev National Institute of Standards and Technology Optical Technology Division, Gaithersburg, MD Infrared Spectral Radiance Scale.
Remote Sensing Basics | August, Calibrated Landsat Digital Number (DN) to Top of Atmosphere (TOA) Reflectance Conversion Richard Irish - SSAI/GSFC.
October 29-30, 2001MEIDEX - Crew Tutorial - Calibration F - 1 MEIDEX – Crew Tutorial Calibration of IMC-201 Adam D. Devir, MEIDEX Payload Manager.
VI-5475(SamCalValNotes) 1 SAM (Sun and Aureole Measurement) Calibration Prepared for MODIS/VIIRS Science Team Meeting Dennis Villanucci, Andrew LePage.
Digital Image Processing GSP 216. Digital Image Processing Pre-Processing – Correcting for radiometric and geometric errors in data Image Rectification.
SCM 330 Ocean Discovery through Technology Area F GE.
Radiometric Correction and Image Enhancement Modifying digital numbers.
RETRIEVING BRDF OF DESERT USING TIME SERIES OF MODIS IMAGERY Haixia Huang, Bo Zhong, Qinhuo Liu, and Lin Sun Presented by Bo Zhong Institute.
1 Reflected Solar Calibration Demonstration System - SOLARIS K. Thome, D. Jennings, B. McAndrew, J. McCorkel, P. Thompson NASA/GSFC.
CALCON September B. Carol Johnson, Steven W. Brown and Howard W. Yoon National Institute of Standards and Technology Gaithersburg, MD Radiometric.
SeaWiFS Calibration & Validation Strategy & Results Charles R. McClain SeaWiFS Project Scientist NASA/Goddard Space Flight Center February 11, 2004.
Use of the Moon as a calibration reference for NPP VIIRS Frederick S. Patt, Robert E. Eplee, Robert A. Barnes, Gerhard Meister(*) and James J. Butler NASA.
1 CLARREO Advances in Reflected Solar Spectra Calibration Accuracy K. Thome 1, N. Fox 2, G. Kopp 3, J. McCorkel 1, P. Pilewskie 3 1 NASA/Goddard Space.
2015 GSICS Annual Meeting, Deli India March 16~20, 2015 Xiuqing Hu National Satellite Meteorological Center, CMA Yupeng Wang, Wei Fang Changchun Institute.
Visible vicarious calibration using RTM
Thomas C. Stone U.S. Geological Survey, Flagstaff, AZ USA GSICS Research Working Group Meeting EUMETSAT 24−28 March 2014 Using the Moon as a Radiometric.
The “Monitor to measure the Integral TRAnsmittance” (MITRA)
PLEIADES Lunar Observations Sophie Lachérade, Bertrand Fougnie
Paper under review for JGR-Atmospheres …
Pre-launch Characteristics and Calibration
NOAA VIIRS Team GIRO Implementation Updates
VIS/NIR reference instrument requirements
Tim Hewison (1) Sébastien Wagner (1), Tom Stone (2), Gary Fowler (1)
Calibrating the METEOSAT SEVIRI solar channels using lunar observations Sébastien Wagner (1) Bartolomeo Viticchie (1), Tom Stone (2), Tim Hewison(1), Gary.
Lunar observation data set preparation
Update on Lunar Calibration Development
Fangfang Yu and Xiangqian Wu
SEVIRI Solar Channel Calibration system
Fangfang Yu and Xiangqian Wu
MODIS and VIIRS Reflective Solar Bands Calibration Methodologies and
Meteorological Satellite Center Japan Meteorological Agency
Vicarious calibration by liquid cloud target
The ROLO Lunar Calibration System Description and Current Status
GOES-16 ABI Lunar Data Preparation to GIRO
An Overview of MODIS Reflective Solar Bands Calibration and Performance Jack Xiong NASA / GSFC GRWG Web Meeting on Reference Instruments and Their Traceability.
Sébastien Wagner (1) Tom Stone (2), Gary Fowler (1), Tim Hewison (1)
MODIS Lunar Calibration Data Preparation and Results for GIRO Testing
Measurements of the Moon by CLARREO Pathfinder and ARCSTONE
Update on Advancing Development of the ROLO Lunar Calibration System
Future Developments of the Lunar Calibration System
Using the Moon for Sensor Calibration Inter- comparisons
Example of sensitivity analysis Sophie Lachérade, Bertrand Fougnie
Outcome of the Second Joint GSICS/IVOS Lunar Calibration Workshop
Lunar reflectance model based on SELENE/SP data
Effort toward Characterization of Selected Lunar Sites for the Radiometric Calibration of Solar Reflective Bands Fangfang Yu1, Xi Shao1, Xiangqian Wu2.
Changchun Institute of Optics Fine Mechanics and Physics
S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS) Lunar Calibration using GSICS Implementation of the ROLO model (GIRO) for Reflective Solar Bands.
Lunar data preparation for PROBA-V
National Satellite Meteorological Centre
Moving toward inter-calibration using the Moon as a transfer
Lunar Observation Data for GIRO Landsat–8 Operational Land Imager
Validation of airborne 1
TanSat/CAPI Calibration and validation
Lingling Ma, Yongguang Zhao, Na Xu, Xiuqing Hu, Chuanrong Li
Current Status of ROLO and Future Development
Consistent calibration of VIRR onboard FY-3A to FY-3C
Moving toward inter-calibration using the Moon as a transfer
Lunar calibration of COMS visible channel using GIRO
Shanghai Institute of Technical Physics , Chinese Academy of Science
Introduction on the FY historical Big Data Reprocessing project
goes-16/17 abi lunar calibration
Lunar irradiance measurement and modelling
Update on Lunar Measurements in China
Lunar Calibration Workshop Activities
Toward a synergy between on-orbit lunar observations
Presentation transcript:

Characterization,calibration and traceability for lunar observation 2nd GSICS/IVOS Lunar calibration workshop Characterization,calibration and traceability for lunar observation Benyong Yang byyang@aiofm.ac.cn Anhui Institute of Optics and Fine Mechanics,Chinese Academy of Science

Outline Background Field calibration and atmospheric correction for ground lunar observation Lab calibration and comparison for ground lunar observation instrument Summarization (Just propose a preliminary calibration plan for ground lunar observation)

The primary consideration is absolute accuracy with SI traceability Background 2nd GSICS/IVOS Lunar calibration workshop For Current lunar observation and irradiance model, The absolute accuracy is not meet the need of in-flight calibration for satellite remote sensors. The primary consideration is absolute accuracy with SI traceability A new lunar measurement set and high accuracy and calibration system become more and more important for lunar observation instruments Combination between Field calibration and Lab calibration is very necessary

Field calibration for lunar observation instruments using sun as reference on Mountain Twilight condition Using the sun as iradiance calibration reference Using lanley_plot method to correct atmosphere effect and esteblish response relation between response voltage of instruments/V0 and TOA solar irradiance Scale can be traced from TOA solar spectral irradiance Calibration be performed in dawn and dusk (sun zenith angle >60°,airmass 3~) when the direct sunlight is weak ,close to lunar and meet the response dynamic range of observation instruments) Calibration site will be selected on high moutain: altitude high ,for example: Bright summit in yellow moutain,1860 meters above sea level; Ling moutain in Beijing, about 2000 meters avove sea level; Stable atmosphere during the calibration observation procedue

Ground lunar observation instrument:lunar photometer(CE-318U) Field calibration for lunar observation instruments 1.Retrieval irradiance response coefficient Step1: continuously auto-measurements will be permormed (dawn of a day ) Step2: Lanley_plot using measurement value vs airmass and get V0 (response voltage of instruments for TOA solar iradiance) Ground lunar observation instrument:lunar photometer(CE-318U) Step3:Irradiance response coefficient will be retrieved : k(λ)=E0(λ)/V0 (λ) A brief summary: Calibration result: Irradiance response coefficient :k(λ) Traceabilit : TOA solar irradiance Disadvantage: Time consuming and regorous conditions, few opportunities May low accuracy because of response dynamic range

Field calibration for lunar observation instruments Field Cross-calibration to transfer solar irradiance scale Field inter calibration for lunar observation instrument using standard lunar photometer as reference; For business and operation?

A novel lunar Langley_plot observation by time phase correction based on lunar irradiance model Although the absolute radiometric uncertanty is high(5%~10%) but the temporal relative uncertanty is low(about 1% maybe) for Current lunar irrdiance model (ROLO or GIRO) Using Time phase correction method based on ROLO model, the moon become a irradiance relatively invariant planet for the ground observator Perform the langley_plot lunar observation using the post timephase-correction lunar irradiance as relative stability reference. Nomalizing refrence V0 through the whole night lunar observation will be retrieved by langley_plot procedue. Using time-phase nomalized measurement V and instrument’s irradiance response coefficent (k) ,the lunar TOA irradiance will be retrieved. A brief summary: Retrieve :lunar TOA Irradiance and V0 (observation reference time) Irradiance sponse coefficient k(λ) ; relative time phase accuracy of lunar irradiance model is need, not need low uncertanty for absolue accuracy. Traceabilit : TOA solar irradiance Advantage: effective correction of atmosphere , maybe low uncertainty.

A novel lunar Langley_plot observation by time phase correction based on lunar irradiance model V0(t0) and τ was retrieved based on Langley_plot equation V0(t0): Instrument’s response voltage of lunar TOA irradiance in t0 ; Τ: night aerosol optical depth σ(t): time phase correction factor based on Lunar model TOA Lunar irradiance at t0 was retrieved based on V0(t0) and irradiance response coeffitient k Lunar langley_plot observation and algorithm flow

Lab calibration for lunar observation instruments Field calibration using sun and lunar as reference is time consuming , regorous conditions and few opportunities ; lab calibration system for business operation must be developed; Irradiance calibration system based on tunable laser illuminated integrating sphere: monochromatic and modulate intensity meet the weak light detect; The scale can be transfered by trap detector and traced from cryogenic radiometer(low uncertainty 0.02 %) FOV of instrument will be measured based on fine spatial scan using laser as reference ;Fov will be used to realize transferation between irradiance coefficient and radiance coefficient. A moon simulator has been developed using tunable laser illuminated integrating sphere.

Lab calibration for lunar observation instruments cryogenic radiometer (absolute power scale) Radiance and Irradiance responsibility coefficient : C(λ) k(λ) will be retrieved: 1.Calibration will be performed using tunabe laser illumunated integrating sphere as reference resource; 2.Standard transfer will be realized using trap detector ; 3.Standard quantity will be Traced from high accuracy cryogenic radiometer Radiance geometrical factor (solid angle , aperture area) Irradiance geometrical factor (aperture area) TRAP detector (power responsivity) Standard radiance photometer (radiance responsivity) Standard irradiance photometer (irradiance responsivity) tunable laser illumunated integrating sphere Standard radiance source (spectral radiance) lunar Irradiance simulator Standard irradiance source (spectral irradiance) FOV measurement sit lunar photometer (radiance responsivity) Solid angle lunar photometer (irradiance responsivity) Standard quantity transfer and traceability flow

Lab calibration for lunar observation instruments

Lab calibration for lunar observation instruments FOV measurement sit Based on spacial scan using laser resource Transfer between irradiance responsivity and radiance responsivity

Lab calibration for lunar observation instruments LAB FOV measurement result using laser as reference Field FOV measurement result using sun as reference Absolute Spectral responsivity using irradiance calibraion

Lab calibration for lunar observation instruments Calibration and scale transfer using Field calibrated lunar photometer based on langley_plot observation as reference; Calibration based on lab irradiance calibration system (equation 1) or lab radiance calibration system (equation 2) ; Inter comparison and testify between lab calibration and field calibration. (1) (2)

summarization Lunar observation calibration and traceability based on Lab system: Irradiance calibration system based on tunable laser illuminated integrating sphere, the scale trace from cryogenic radiometer by trap detector. Lunar observation atmosphere correction based on a novel lunar langley_plot method by the moon itself (time phase corrected moon)based on ROLO model.

Thanks for attention !