WEAR DEBRIS ANALYSIS 9/20/2018.

Slides:



Advertisements
Similar presentations
D e t e c t o r s f o r H P L C.
Advertisements

Presentation on Wear Measurement Irwin O. Toppo Mechanical engineering Indian Institute of Science, Bangalore, India.
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Atomic Emission Spectroscopy. Chem Introduction Atomic absorption is the absorption of light by free atoms. An atomic absorption spectrophotometer.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Flame photometry.
427 PHC. Introduction  Spectrometric methods are a large group of analytical methods that are based on atomic and molecular spectroscopy.  Spectroscopy.
Atomic Emission Spectroscopy
Atomic Emission Spectroscopy (AES)
X Ray Flouresence Analysis (XRF). XRF X-Ray Fluorescence is used to identify and measure the concentration of elements in a sample X-Ray Fluorescence.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Spectroscopy Chapter 7.
1 AP 5301 / 8301 Instrumental Methods of Analysis Course Coordinator: Prof. Paul K. Chu Electronic mail: Tel: Fax:
Advanced Higher Chemistry Unit 1 Spectroscopy. Spectroscopy  Spectroscopy is used to give information regarding the structure of atoms or molecules.
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
Mass Spectroscopy 1Dr. Nikhat Siddiqi. Mass spectrometry is a powerful analytical technique that is used to identify unknown compounds, to quantify known.
Condition Monitoring Adam Adgar School of Computing and Technology.
What Are Some Types of Spectroscopy ?
Origin of an Atomic Absorption Peak E2E2 E1E1  E = h Frequency Intensity Energy Transition Absorption Spectrum 1.
Atomic Emission Spectrometry
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Flame Photometry Flame atomic emission spectrometry
Field Methods of Monitoring Atmospheric Systems Chemical Analysis of Particulate Matter Copyright © 2006 by DBS.
Forensic Instrumentation
6- PRENTICE HALL ©2007 Pearson Education, Inc. Upper Saddle River, NJ CRIMINALISTICS An Introduction to Forensic Science, 9/E By Richard Saferstein.
Atomic Absorption Spectrometry
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
X-Ray Fluoresence Meter/Detector. Introduction Air monitoring data is useful for: *Assessing the health risks to the public and response workers. *Selecting.
Conditioned-Based Maintenance
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
Fluorescence Spectroscopy
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Figure 8.3 gives the basic layout of a continuous wave NMR spectrometer. These intruments were the original type of instrument and have largely.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Carbon Dioxide Monitoring
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
Chapter 6 Inorganic Analysis 6.1 Notes Pg
Okobu! Do Now: – Take out Notes and prepare for Quiz Agenda: – Review of Density techniques – Refractive Index HW: – Ch 4 #3,5,7-10,19-22,28-35 due 11/1.
By Maryum Atique M.Phill chemistry University of Agriculture.
By : VAIBHAV KUMAR IV YEAR, VII SEM ELECTRICAL ENGINEERING.
RAMAN EFFECT.
Thomas M. Canty, P.E. J.M. Canty Inc. Buffalo, NY
Welcome.
Flame Emission Spectrometry
SUSTAINABLE DRILLING OF OIL & GAS WELLS
NDT (Nondestructive Testing) for Welding Result
Types of Fractures by Projectiles
Spectroscopy Chapter 7.
ANALYTICAL CHEMISTRY deals with methods for determining the chemical composition of samples. Dr Seemal Jelani ENVR-303 6/16/2018.
Chapter 6 INORGANIC ANALYSIS
Spectroscopy.
PPT 206 Instrumentation, Measurement and Control
Introduction & Its instrumentation
Sorting Technologies for CCA Treated Wood
Introduction - characterization of materials.
Tribology Course Seminar Course: Machine Design II By: Kavya M Bhat
Alberto Sánchez-Marroquín, S. T. Parker, J. Trembath, I. Burke, J. B
Nuclear Magnetic Resonance
Inorganic Analysis 6.1 Notes Pg
Spectroscopy.
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
Scanning Electron Microscopy (SEM)
Planck’s law: E=hn =hc/l
AP 5301 / 8301 Instrumental Methods of Analysis
RTI Laboratories receives Ford Motor Company Approvals for “Test G” Analysis In late February 2019, RTI completed the final steps in Ford transmission.
Kaustubh K. Rane Department of Materials Science and Engineering,
Presentation transcript:

WEAR DEBRIS ANALYSIS 9/20/2018

INTRODUCTION Wear of sliding components result in reduced mechanical efficiency. Lubrication is provided between the moving surface to minimize the wear. Wear Debris Analysis has proven useful in providing supporting evidence on the bearing or gear status. It also provides information on the wear mechanism, which is involved. 9/20/2018

USED OIL CONTAMINATION – TIME TRENDS 9/20/2018

If abnormal conditions arise, the concentration may increase by D-E. when the machinery is now or recently overheated, a sharp rise in metallic concentration occurs from A to B . Once this phase is completed, the concentration should remain steady, the oil shouls then be changed. Some residual wear metal products remain from the old oil and circulate in the original oil following the oil change at c. Normal functioning the metallic concentration would be expected to increase slowly as by C-D If abnormal conditions arise, the concentration may increase by D-E. 9/20/2018

WEAR PROCESS MONITORING TECHNIQUES 9/20/2018

Direct Debris Collection Method Wear debris in the lubricant is detected in the machine by arranging for the oil flow through a device, which is sensitive to the presence of debris. Two types of filter system are mainly present Special filters   Existing Filter system 9/20/2018

Debris Collection Method Wear debris is collected in a device, fitted to the machine which is convenient to remove, so that the debris can be extracted for examination. 9/20/2018

Magnetic Plugs 9/20/2018

This method only detect ferrous material. It is an “on-line” control method, magnetic plugs are used in oil-lubricated machines This method only detect ferrous material. The magnetic plugs captures a large number of particles are detected ,which would not normally be recorded by means of ferrography. An unacceptable coating is visible. This indicates abnormal wear. Magnetic plugs are used in the modern aircraft engines where particle sizes are in the order of 0.2-1 µm are found. 9/20/2018

Large individual fragments An unacceptable coating can be characterized by the following conditions. Large individual fragments Pieces which can be identified as flakes from a bearing Flat fragments A large number of whiskers  Particularly long whiskers 9/20/2018

Lubricant Sample Analysis A sample of lubricant is extracted from a machine and analyzed for wear debris contamination. There are two most widely used methods 1. Spectrometric oil analysis program (SOAP) 2. Ferrography 9/20/2018

Spectrometric oil analysis program (SOAP) It is a maintenance tool which is used to check the condition of the oil lubricated mechanical systems(Examples: Motors, Gear boxes, Hydraulic systems). The quantity can indicate something about the magnitude of the wear and the type of wear metals can reveal which component is wearing out. The quantity and type of wear metals in sample of lubricating oil is determined Spectrometric oil analysis program (SOAP) 9/20/2018

Emission spectroscopy It is an optical instrument The sample is burnt in between two electrodes It produces a light of different wavelengths The intensity of light is proportional to the concentration of the metal in the sample. 9/20/2018

Atomic absorption spectroscopy 9/20/2018

  Limitations of soap  Large particles (E.g. bearings can breakdown due to few large particles)  Defects which occurs quickly (E.g. due to the lack of lubricating oil or due to bearings which burn up)  Defects where no wear metals are formed.(E.g. breakdown due to metal fatigue). 9/20/2018

Application of soap 1. It is used in situations where breakdowns are expensive. 2. It is widely used in the military services. 3. In US, it is used by the Air force, Navy and the Army. 4. It is used for many civil aviation companies. 9/20/2018

Ferrography It is a technique which is based upon the systematic collection of oil samples from an oil- lubricant. The method identifies, isolate and classify wear particles from machine parts. A magnetic field is used to sort the wear particles in the flowing oil. This technique was used successfully to monitor the condition of military aircraft engines, gear boxes and transmissions. 9/20/2018

Type of equipments used in wear particle analysis Direct –Reading(DR) ferrography Analytical ferrograph system Ferrorgram scanner. 9/20/2018

1. Direct – Reading (DR) Ferrography 9/20/2018

9/20/2018

2. The Analytical Ferrograph . The Analytical Ferrograph is used to prepare a Ferrogram -- a fixed slide of wear particles for microscopic examination and photographic doc. The Ferrogram is an important predictive tool. 9/20/2018

9/20/2018

3. Ferrorgram scanner. The energy-dispersive (X-ray) spectrometry (EDS) technique is a familiar elemental analysis attachment to a scanning electron microscope (SEM) where electrons are used as the primary energy source to excite the X-ray spectra. 9/20/2018

SEM 9/20/2018

CONCLUSION   The wear debris monitoring method access the nature of the particles generated when components wear. They can indicate exact nature of the machine problem indicate the amount of debris present indicate the size distribution of debris indicate the physical form of debris application of chemical analysis of debris 9/20/2018

REFERENCES: VENKATRAMAN.A, SENTHILVELAN.T, “WINTER SCHOOL ON RECENT TRENDS IN DIAGNOSTIC MAINTENANCE”. PRABHU.B.S, “WORKSHOP ON PLANT ENGGINEERING AND INDUSTRIAL TRIBOLOGY”. www.wikipedia.org www.encyclopedia.com 9/20/2018

Thank you 9/20/2018