ATEX fans st 20.09.2018 ATEX.

Slides:



Advertisements
Similar presentations
Hazard Survey Dow Fire and Explosion Index is the most popular form of hazard survey. A formal systematized approach using a ranking form (similar to an.
Advertisements

VSD AND SS DRIVING ATEX MOTORS February Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions.
Complied by H S Dave DDISH Surat Health & Safety at Work Hazards from Aerosols.
1 Module 3 Ignition Control. 2 Terminal Objectives Upon the successful completion of this module, participants will be able to explain the work procedures.
Twinning Project RO2006/IB/EN/09 1 Saxony-Anhalt State Environmental Protection Agency Wolfgang GarcheBukarest Wolfgang Garche Saxony-Anhalt.
NEW TECHNOLOGY IN MINE SURVEYING AND ITS IMPACT ON SAFETY IN THE UNDERGROUND WORKINGS OF A MINE.
CERTIFICATION OF EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES What do I Really Have to Do ?
Phare SL Implementation of Technical Regulations on Company Level Breakout session Atmospheres Explosives Low Voltage Electromagnetic Compatibility.
Source: ec.europa.eu/CEmarking CE marking makes Europe’s market yours!
Low Voltage Directive New Approach. Directive Overview Guidelines on application and Recommendations Safety objectives Documentation LVD standardisation.
Blabo® Automated Tank Cleaning ExxonMobil 2009 Article Electrical standards Designed for operation in hazardous areas. Constructed for zone 1, and some.
Copyright © Flammable & Combustible Liquids.
Health & Safety at Work Hazards from Aerosols.  To understand the hazards associated with aerosol products.  Understand how to control these hazards.
U D T Workshop on the Pressure Equipment Directive, Warsaw June 2004 INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC SYSTEM OF ENSURING.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
© BA Electrical Machines - 1 M3000 Ex-motors August 2002 M3000 Low Voltage Motors for Hazardous Areas.
Phare SL New Approach Directive laying down E.R. to avoid or reduce any risk to health and safety of operators and other exposed persons Risks to.
June SURVEY OF EUROPEAN DIRECTIVES European directives are based on the new approach in order to provide free movement of goods in the single market.
Essentials of Machine Safety Standards in Perspective.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Basic Awareness Training for all Staff
Explosion An explosion is a rapid expansion of gases resulting in a rapid moving pressure or shock wave. The expansion can be mechanical or it can be.
ENTERPRISE AND INDUSTRY DIRECTORATE GENERAL European Commission 1 ATEX Directive 94/9/EC UNECE WP.6 Break-out session on equipment for explosive atmospheres.
The work of CEN/TC 305 Potentially explosive atmospheres-
Page June 2015 OICA position on venting EVSTF-04-11e.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Product & Technology Quality. Excellence. Support SIL Explanation 27.JAN 2006 Automation & Safety.
National Legislation on in- service inspections and the PED.
Support for the Modernisation of the Mongolian Standardisation system – EuropeAid/134305/C/SER/MN Training on standardisation Support to the Modernisation.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
BY FRANS WILBRINK WILBRINK & ASSOCIATES. OUTLINE Classify the different types of hazardous areas Identify the risks associated with each of these areas.
Flammable Liquids Directorate of Training and Education
Health and Safety Legislation E5: Human Factors Design IB Technology.
Rev. 1 © Chevron 2009 Hot Work Awareness Plus. Rev. 1 © Chevron Training Objectives  To explain the type of work which may constitute Hot Work.
1 ATEX classification air motors, Dagmar Dübbelde ATEX CLASSIFICATION AIR MOTORS.
Lesson 5 Workplace Hazardous Material Information System (WHIMIS) and
CONFINED SPACE ENTRY TRAINING PROGRAM
SERVICES, LLC 1 1.
Strategy for conformity of non-standard cryogenic equipment
Transboundary movement of used batteries of used lead batteries, in draft Guidelines for environmentally sound management of used lead batteries Jaromír.
Risk Assessment and Accident Prevention
Regulation (EU) No 2015/1136 on CSM Design Targets (CSM-DT)
SYSTEM SAFETY AND THE TECHNICAL AUTHOR
EMC & COMPLIANCE ENGINEERING
EET 422 EMC & COMPLIANCE ENGINEERING
Ron Sinclair Managing Director – Baseefa
IECEx Industry Seminar Integrating IECEx and ATEX for Europe
Health & Safety at Work Hazards from Aerosols
Quality Risk Management
THUM Adapter Impact on Hazardous Area Classification
Health & Safety at Work Hazards from Aerosols
CONSTRUCTION BS (BS 4533) K.F. Chan (Mr.) MEBS 6002.
Pressure Equipment Workshop September 2007 – Day 1
Assemblies Intentions and enforcement
Risk informed separation distances for hydrogen refuelling stations
SCOTTISH BORDERS SAFETY FORUM
ECMA-287 Safety of Electronic Equipment Safeguards to reduce harmful exposure to energy sources Ecma TC12 Rue du Rhône CH-1204 Geneva - T: +41.
Flammable & Combustible Liquids
Lesson 5 Workplace Hazardous Material Information System (WHIMIS) and
Smokes extraction principle
Mattias Skafar Head of Quality Division
Hazardous Area Classification
INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC
Analysis of likelihood, risks and consequences of major accidents involving category acute toxic 3 dermal substances and assessment of the impact of covering.
installations and assemblies
The Control of Electromagnetic Fields at Work Regulations 2016
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
National Legislation in the Pressure Sector and the PED
Risk Management Student Powerpoint
Presentation transcript:

ATEX fans st 20.09.2018 ATEX

experience since 1985 Hoffmann La Roche (Basle, CH) transport of explosive, toxic and corrosive gases 2000 m³/h 70 mbar T° : - 50°C … + 200°C system pressure 8 bar 12 bar explosion resistance st 20.09.2018 ATEX

1985 biogas Hofstetter (CH) transport of biogas (methane) up to 2000 Nm³/h with 180 mbar 6 or 10 bar explosion resistance st 20.09.2018 ATEX

1992 solvent vapour Hoffmann La Roche (Basle,CH) solvent vapour 200 m³/h model ER10 LRV- installation with 30 fan units st 20.09.2018 ATEX

1993 to 1996 explosion tests and certificate PTB (Physikalisch-Technische Bundesanstalt, Braunschweig) ER IIB3/100/520 zweistufig ER IIA/100/520 zweistufig ER IIB3/100/500 ER IIA/100/500 st 20.09.2018 ATEX

project ATEX 94/9/EG In January 1999 a project had been set up to extend the range of zone-0 fans and to receive the ATEX certificate in March 1999 the order of Sanofi Synthélabo (France) for 6 fans intensified our efforts the required new size had been incorporated into our project we took the necessary steps to receive the ATEX certificate st 20.09.2018 ATEX

sanofi 1999 Sanofi Synthélabo (F) transport of solvent vapours 1500 Nm³/h system ER10 up to today 20 units installed at this customer st 20.09.2018 ATEX

ATEX 100 - ATEX 137 99/92/EC (ATEX 137) is intended to complement the previously published 94/9/EC (ATEX 100a). These two directives cover different areas and are intended to achieve different objectives. Responsibilities and duties are shared between the manufacturer and user (employer). 1999/92/EC (ATEX 137) Covers health and safety protection of workers Duties are placed on the employer Intended to ensure that workers enjoy a minimum level of protection throughout all member states 1994/9/EC (ATEX 100a) Covers products intended for use in hazardous areas Duties are placed on the manufacturer/supplier of the product Intended to facilitate the free movement of goods within the EU Both ATEX 137 and ATEX 100a became mandatory on 1st July 2003. and set out the minimum requirements. Member states are free to introduce more stringent measures if they wish. st 20.09.2018 ATEX

directive for manufacturers ATEX 100 After 30 June 2003 products may be placed on the market in the EU territory, freely moved and operated as designed and intended in the expected environment only if they comply with directive 94/9/EC. Directive 94/9/EC provides Essential Health and Safety Requirements (EHSRs, listed at Annex II) for non-electrical equipment intended for use in potentially explosive atmospheres and equipment intended for use in environments which are potentially explosive due to dust hazards and protective systems and for devices intended for use outside explosive atmospheres which are required for or contribute to the safe functioning of equipment or protective systems with respect to risks of explosion. st 20.09.2018 ATEX

group and category Group I comprises equipment intended for use in the underground parts of mines, and to those parts of surface installations of such mines, likely to become endangered by firedamp and/or combustible dust Group II comprises equipment intended for use in other places likely to become endangered by explosive atmospheres Our range of product come normally in application covered with this group, sub-divided into 6 categories st 20.09.2018 ATEX

category 1G (for zone 0) Cat. 1G comprises products designed to be capable of remaining in areas in which explosive atmospheres caused by mixtures of air and gases, vapours, mists or air/dusts mixtures are highly likely to occur and are present continuously, for long periods of time or frequently Equipment of this Category is characterised by integrated explosion protection measures functioning in such a way that: in the event of a failure of one integrated measure, at least a second independent means of protection provides for a sufficient level of safety; or, in the event of two faults occurring independently of each other a sufficient level of safety is ensured. st 20.09.2018 ATEX

category 2G (for zone 1) Cat. 2G comprises products designed to be capable of remaining in areas in which explosive atmospheres caused by mixtures of air and gases, vapours, mists or air/dust mixtures are likely to occur The explosion protection relating to this Category must function in such a way as to provide a sufficient level of safety even in the event of equipment with operating faults or in dangerous operating conditions which normally have to be taken into account. st 20.09.2018 ATEX

category 3G (for zone 2) Cat.3G comprises products designed to be capable of remaining in areas in which explosive atmospheres caused by mixtures of air and gases, vapours, mists or air/dust mixtures are less likely to occur and if they do occur, do so infrequently and for a short period of time only. The design of the products of this category must provide a sufficient level of safety during normal operation. st 20.09.2018 ATEX

There is the same classification for air/dust mixtures Category 1D (for zone 20) Category 2D (for zone 21) Category 3D (for zone 22) Actually, we have a complete range of solution other for the category 1D st 20.09.2018 ATEX

standard fan without specific risks designed without specific measurements standard design st 20.09.2018 ATEX

category 2 or 3 (G and/or D) motor EEx nA EEx e or EEx de (for FU) non-sparking design prevention of the generation of sparks or hot surfaces by appropriate design st 20.09.2018 ATEX

category 2 or 3 / gastight (G and/or D) motor EEX nA EEx e or EEx de (for FU) non-sparking design seal gastight design to avoid escape of gas into the atmosphere or towards the motor st 20.09.2018 ATEX

category 2 (G and/or D) non-sparking design seal design ER motor EEx nA EEx e or EEx de (for FU) also under abnormal circumstances the fan must not generate any sparks or hot surfaces st 20.09.2018 ATEX

category 1G design ER non-sparking design flame arresters seal ATEX

category 1 cat.1 = (permanently explosive medium) requires additional measurements. Up to today all solutions are limited to gas (cat.1G), since dust (cat.1D) cannot pass the flame arresters. st 20.09.2018 ATEX

requirements for cat.1G protection measurements must guarantee in the event of a failure of one integrated measure, at least a second independent means of protection provides for a sufficient level of safety; or, in the event of two faults occurring independently of each other a sufficient level of safety is ensured solution: explosion resistant design + flame arresters st 20.09.2018 ATEX

requirements for cat.1G the protective systems must be able to withstand an explosion inside the fan. the protective systems must be arranged in such a way, that any dangerous chain reaction is impossible. Flames or deflagrations inside the fan must not escape and cause detonations outside. solution: design ER + flame arresters close to the fan proof by real explosion tests st 20.09.2018 ATEX

flame arresters each new type has been proofed (16x) with the fan by real explosion tests (according to EN 12874) to demonstrate the efficacy of the safety measurements st 20.09.2018 ATEX

Actuelly concept and design ER st 20.09.2018 ATEX

size and sensors the design of the fan and the choice of the material is determined by the expected pressure and temperature in case of an explosion or in case of a fire. Also thermal reaction can cause a heating. The fan withstands an explosion shock without reduction of the safety function of the system. the protective devices are equipped with sensors to indicate a fire or abnormal temperature. The sensors are connected with other elements to stop the process and to separate other parts of the installation. st 20.09.2018 ATEX

operating conditions Sensors measure the temperature at the inlet flame arresters to detect a fire and at the same time they indicate an abnormal temperature of the medium. Fans for category 1G are always designed for specific operating conditions, which are given by speed rate (rotation) operating temperature category of the media pressure under no circumstances the fan can be used outside the range of these specifications ! st 20.09.2018 ATEX

risk analysis hazard identification which hazards exist under normal circumstances, which in the case of a fault (EN 1127-1) risk estimation Probability of occurrence of the identified hazards and of the levels of severity of the possible harm of the considered hazards (see as well EN 1050). risk evaluation and reduction Comparison and decision, whether the risk is acceptable or not st 20.09.2018 ATEX

risks EN 1127-1 probability and volume of explosive media degree of dispersion and concentration ignition sources hot surfaces, flames mechanically generated sparks electric units, motors, switches electrostatic and electrochemical effects lightning electromagnetic waves, radiation, shocks waves, exothermal reactions st 20.09.2018 ATEX

conformity assessment group ll cat.1 cat.2 cat.3 Certification from QS according to ATEX EC type examination technical documentation to Notified Body controlled production , quality system documentation st 20.09.2018 ATEX

quality system compliance with given standards qualification of staff defined responsibility clear workflow complete documentation identification st 20.09.2018 ATEX

identification label conditions for use identification category 1G into the fan and 2G out G= for gas surface max 135°C (T4) motor for frequency control EEx de st 20.09.2018 ATEX

0080 1G / 2G – IIA – T4 means 0080 : number of the ‚Notified Body‘ who checked the quality system (Ineris for us) 1G : inside category 1 for gas / 2G : outside category 2 for gas IIA : explosion group of the transported gases T4 : maximal temperature of surfaces st 20.09.2018 ATEX

explosion tests (type examination) according to EN 12874 1-inlet 2-outlet 3-throttlel 4-ignition on several points 5-flame arrester at inlet 6-flame arrester at outlet 7-flame sensor 8-pressure sensor st 20.09.2018 ATEX

product range ER st 20.09.2018 ATEX

ATEX links directive 94/9/EG (ATEX 100a) http://europa.eu.int/comm/enterprise/atex/direct/newapproach.htm directive 1999/92/EG (ATEX 137) http://europa.eu.int/comm/enterprise/atex/dir92-en.pdf guideline http://europa.eu.int/comm/enterprise/atex/guide/index.htm standards EN 1127-1 : explosive atmosphere http://www.pellmont.ch/sikeda/deutsch/cen114/en1127-1.htm st 20.09.2018 ATEX

thank you for your attention FläktComp Sweden AB Slöjdgatan 3 352 46 Växjö Sweden Tel +46 470 485 50 Fax +46 470 485 60 info@flaktcomp.se www.flaktcomp.se st 20.09.2018 ATEX