Imaging System Components

Slides:



Advertisements
Similar presentations
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Advertisements

Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Digital Radiography.
Oscilloscope. 1.Electron guns 2.Electron beams 3.Focusing coils 4.Deflection coils 5.Anode connection 6.Mask for separating beams for red, green, and.
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Fluoroscopy: Viewing Systems
Fluoroscopy Equipment
Quality Control Rad T 110.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
Special Imaging Systems
F luoroscopy. 2 Fluoroscopy system 3 Different fluoroscopy systems  Remote control systems Not requiring the presence of medical specialists inside.
Fluoroscopy Intro to EQUIPMENT
ECE 5th SEMESTER Subject Consumer Electronics (CE)
FLUOROSCOPY EQUIPMENT
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
The Television Picture
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Control room High resolution flat screen monitors CCD image intensifiers are easily identified by their shape A modern fluoroscopic suite.
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Pulse-Height Analyzers Basic Functions Single Channel Analyzers Time Methods Multi-channel Analyzers.
Appendix H: Chapter 40: Fluoroscopy
What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.
Chapter 3: Factors of Image Quality 1. Interlaced vs. progressive scanning 2. Matrix size 5. Field of view (FOV) 3. Vertical resolution 4. Horizontal resolution.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
TELEVISION CAMERA TUBES
Oscilloscope The main purposes of the oscilloscope are: Can view the input waveform voltage or current. Can measure instantaneous values of the input waveform.
RAD 254 Chapter 27 Digital Fluoroscopy
Imaging System Components M A Oghabian Medical Physics Group, Tehran University of Medical Sciences
Modulation Transfer Function (MTF)
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
FLUOROSCOPY & IMAGE INTENSIFICATION Sergeo Guilbaud, RT School of Radiologic Sciences.
Basis of Mammography F. Milano Dept. Clinical Physiopathology University of Florence
IAEA International Atomic Energy Agency Fluoroscopy Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(2)
Patient is placed between X-ray tube and silver halide film.
T ELEVISION Simplified cross-sectional view of a Vidicon TV camera tube 2Communication Systems (EC-326)
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
01 X-ray Tube.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Resident Physics Lectures
Laboratory equipment Lecture (3).
Oscilloscope.
TELEVISION Camera Tube
X-ray Production Sharif Qatarneh Medical Physics Division
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IMAGE ORTHICON.
Part No...., Module No....Lesson No
Fundamentals of video and TV
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
COURSE: AUDIO VIDEO ENGINNERING COURSE CODE:
Medical Imaging Imagining Modalities.
Fluoroscopic Unit Thomas Edison 1896.
Equipment Operation and Maintenance
CATHODE RAY TUBE.
Resident Physics Lectures
Fluoroscopic Image Intensifier Image production
Fluoroscopy: Viewing Systems
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy – Viewing Systems Optical Mirrors TV Camera & TV Camera Tubes Charge Coupled Devices (CCD) Based on: Principles of Radiographic Imaging, 3rd.
Fluoroscopy – Viewing Systems TV Monitors
Flouroscopic imaging.
Fluoroscopic Image Quality Considerations
Fluoroscopic Image Intensifier Image Production
Fluoroscopy: Static Image Recording Systems
Fluoroscopic Image Quality Considerations
Computed Tomography (C.T)
Presentation transcript:

Imaging System Components Part No...., Module No....Lesson No Module title Imaging System Components M A Oghabian Medical Physics Group, Tehran University of Medical Sciences www.oghabian.net Part …: (Add part number and title) Module…: (Add module number and title) Lesson …: (Add session number and title) Learning objectives: Upon completion of this lesson, the students will be able to: … . (Add a list of what the students are expected to learn or be able to do upon completion of the session) Activity: (Add the method used for presenting or conducting the lesson – lecture, demonstration, exercise, laboratory exercise, case study, simulation, etc.) Duration: (Add presentation time or duration of the session – hrs) Materials and equipment needed: (List materials and equipment needed to conduct the session, if appropriate) References: (List the references for the session) IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Part No...., Module No....Lesson No Module title Tungsten Target Electrons (+) (--) Cu cathode Titling angle q Sin20° = 0.342, Sin16.5 =0.284 Apparent focal spot size X-Rays IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Add module code number and lesson title Focal Spot Add module code number and lesson title

Add module code number and lesson title

Add module code number and lesson title Focal Spot MTF Add module code number and lesson title

MTF of various shape of Focal Spot Add module code number and lesson title 7 MTF of various shape of Focal Spot Add module code number and lesson title

Add module code number and lesson title 8

Add module code number and lesson title

Change of focal spot size with tube loading Add module code number and lesson title

Part No...., Module No....Lesson No Module title A schematic of the high-voltage cathode-anode circuit. IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Part No...., Module No....Lesson No Module title Ripple factor: The variation in the voltage across the x-ray tube expressed as a percentage of the maximum value. Full-wave rectification better Three-phase full wave (6 phase) rectification- better still. Three-phase full wave (12 phase) rectification- Closer to DC field. IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Add module code number and lesson title Fluoroscopy system Add module code number and lesson title

Different fluoroscopy systems Remote control systems Not requiring the presence of medical specialists inside the X-ray room Mobile C-arms Mostly used in surgical theatres. Add module code number and lesson title

Different fluoroscopy systems Interventional radiology systems Requiring specific safety considerations. Interventionalists can be near the patient during the procedure. Multipurpose fluoroscopy systems They can be used as a remote control system or as a system to perform simple interventional procedures Add module code number and lesson title

Two types of Fluoroscopy are: under-couch tube design over-couch tube design Over-couch tube design offers a greater distance between tube and both patient and intensifier. This improves image quality by reducing geometric unsharpness and reduces radiation skin dose to the patient. Under-couch tube design provides direct fluoroscopy screen and therefor allows operator to be close to the patient. Add module code number and lesson title

Image Intensifier component and parameters Part No...., Module No....Lesson No Module title Image Intensifier component and parameters Part …: (Add part number and title) Module…: (Add module number and title) Lesson …: (Add session number and title) Learning objectives: Upon completion of this lesson, the students will be able to: … . (Add a list of what the students are expected to learn or be able to do upon completion of the session) Activity: (Add the method used for presenting or conducting the lesson – lecture, demonstration, exercise, laboratory exercise, case study, simulation, etc.) Duration: (Add presentation time or duration of the session – hrs) Materials and equipment needed: (List materials and equipment needed to conduct the session, if appropriate) References: (List the references for the session) IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Input Screen Electrode E1 Electrode E2 Electrode E3 Output Screen Electrons Path Output Screen Photocathode +

Image intensifier systems Add module code number and lesson title

Image intensifier component Input screen: conversion of incident X-rays into light photons (CsI) Sodiun- activated caesium iodide 1 X-ray photon creates  3,000 light photons Photocathode: conversion of light photons into electrons Caesium or antimony only 10 to 20% of light photons are converted into photoelectrons Electrodes : focalization of electrons onto the output screen electrodes provide the electronic magnification Output screen: conversion of accelerated electrons into light photons; Zinc Cadmium Sulphide

Image intensifier parameters (I) Conversion coefficient (Gx): the ratio of the output screen brightness to the input screen dose rate [cd.m-2Gys-1] Gx depends on the quality of the incident beam (IEC publication 573 recommends HVL of 7  0.2 mm Al) Gx is directly proportional to: the applied tube potential the diameter () of the input screen input screen of 22 cm  Gx = 200 input screen of 16 cm  Gx = 200 x (16/22)2 = 105 input screen of 11 cm  Gx = 200 x (11/22)2 = 50

Image intensifier parameters (II) Brightness Uniformity: the input screen brightness may vary from the center of the I.I. to the periphery Uniformity = (Brightness(c) - Brightness(p)) x 100 / Brightness(c) Geometrical distortion: all x-ray image intensifiers exhibit some degree of pincushion distortion. This is usually caused by either magnetic contamination of the image tube or the installation of the intensifier in a strong magnetic environment.

Image distortion

Image intensifier parameters (III) Spatial resolution limit: It provides a sensitive measure of the state of focusing of a system it is quoted by manufacturer it can be measured optically it correlates well with the high frequency limit of the Modulation Transfer Function (MTF) it can be assessed by the Hüttner resolution pattern

Line pair gauges GOOD RESOLUTION POOR RESOLUTION

Image intensifier parameters (IV) Overall image quality: threshold contrast-detail detection X-ray, electrons and light scatter process in an I.I. can result in a significant loss of contrast of radiological detail. The degree of contrast is effected by the design of the image tube and coupling optics. Spurious sources of contrast loss are: accumulation of dust and dirt on the various optical surfaces reduction in the quality of the vacuum aging process (destruction of phosphor screen) Sources of noise are: X-ray quantum mottle photo-conversion processes

Image intensifier - TV system Output screen image can be transferred to different optical displaying systems: conventional TV Generating a full frame of 525 lines (in USA) 625 lines and 25 full frames/s up to 1000 lines (in Europe) interlaced mode is used to prevent flickering cinema 35 mm film format: from 25 to 150 images/s photography rolled film of 105 mm: max 6 images/s film of 100 mm x 100 mm

GENERAL SCHEME OF FLUOROSCOPY VIDICON FILM PM REFERENCE kV CONTROLLER X-RAY TUBE GENERAL SCHEME OF FLUOROSCOPY Add module code number and lesson title

Type of TV camera VIDICON TV camera (antimony trisulphide) improvement of contrast improvement of signal to noise ratio high image lag PLUMBICON TV camera (suitable for cardiology) lead oxide lower image lag (follow up of organ motions) higher quantum noise level CCD TV camera (digital fluoroscopy) digital fluoroscopy spot films are limited in resolution, since they depend on the TV camera (no better than about 2 lp/mm) for a 1000 line TV system

Photoconductive camera tube Focussing optical lens Input plate Steering coils Deviation coil Alignement coil Accelarator grids Control grid Electron beam Video Signal Signal electrode Field grid Electrode Electron gun Iris Photoconductive layer

TV camera and video signal يك نوع دوربين مورد استفاده در سيستم فلورسكوپي Vidicon ناميده مي شود كه از شيشه خلأ بـه قـطــر 2 تا 3 سانتي متر و طول 10 تا 20 سانتي متر تشكيل شده است. صفحه ورودي دوربين از سه لايه تشكيل شده است: 1- لايه خارجي از شيشه كه محافظت را بعهده دارد. 2- داخل شيشه از لايه اي از Zinc oxide پوشانده شده، هادي الكتريكي شفاف (Transparent) مي باشد لذا اجازه مي دهد نور به لايه سوم منتقل شود. اين لايه Signal electrod نام دارد. 3- لايه داخل موزائيكي به صورت ميليون ها سلول فتوالكتريك كوچك (Antimony TriSulphide) كه هدايت الكترون را نسبت به افزايش نور افزايش مي دهد (Photoconductor). Add module code number and lesson title

TV camera and video signal طرف ديگر دوربين تفنگ الكتروني است كه از فيلامان، گريد و الكترود شتابدهنده تشكيل شده است. فيلامان براساس حرارت توليد الكترون مي كند. گريد كنترل ميزان جريان الكترون را فراهم مي كند. الكترود شتابـدهنده داراي سـوراخي در مــركــز است كـه الكترون ها از وسط آن عبور كرده و شتاب ميگيرند ( با 20 تا 60 ولت ). الكتــرون هــاي حاصــل از تـفـنگ تحت اثــر فـيـلد هـاي الكتـريكـي نــزديـك تـيـوب دوربين باعث حركات افقي و عمودي منظم ((Scanning شده تا ميدان مستطيلي صفحة حساس Photoconductor را بپوشاند (نام ميدان Raster است).

TV camera and video signal (IV) In a typical television system, on the first pass the set of odd numbered lines are scanned followed by the even numbers (interlaced). The purpose of interlacing is to prevent flickering of the television image on the monitor, by increasing the apparent frequency of frames (50 half frames/second). In Europe, 25 frames are updated every second.

TV camera and Monitor (V) The video signal comprises a set of repetitive synchronizing pulses. In between there is a signal that is produced by the light falling on the camera surface. The synchronizing voltage is used to trigger the TV system to begin sweeping across a raster line. Another voltage pulse is used to trigger the system to start rescanning the television field. A series of electronic circuits move the scanning beams of the TV camera and monitor in synchronism. The current, which flows down the scanning beam in the TV monitor, is related to that in the TV camera. Consequently, the brightness of the image on the TV monitor is proportional to the amount of light falling on the corresponding position on the TV camera.

TV camera and video signal (CCD) Many modern fluoroscopy systems used CCD (charge coupled devices) TV cameras. The front surface is a mosaic of detectors from which a signal is derived.

Schematic structure of a charged couple device (CCD)

Add module code number and lesson title Linear system x(t)  PSF=h(t) y(t) Add module code number and lesson title

Exmaple of System Components in a Medical Imaging system Add module code number and lesson title

Where to Get More Information Part No...., Module No....Lesson No Module title Where to Get More Information Physics of diagnostic radiology, Curry et al, Lea & Febiger, 1990 Imaging systems in medical diagnostics, Krestel ed., Siemens, 1990 The physics of diagnostic imaging, Dowsett et al, Chapman&Hall, 1998 Add module code number and lesson title IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources