AC LIGHTNING PROTECTION Northern Technologies SA

Slides:



Advertisements
Similar presentations
POWER QUALITY BACKGROUND & ELEC-SAVER TVSS
Advertisements

Grid Connect Inverters NUER 19
Electrical Installation
Chapter 12 Transformers. Chapter 12 Transformers.
Concept Design Review (CoDR) Shore Station DC Breaker Cable model Transient Analysis Components.
Surge Protection: Technical Background & Basics. 2 Surge Protection – Agenda Introduction AC Power Basics Power Quality Scope Voltage Transients & Disturbances.
Computer Maintenance Power Quality and Protection Copyright © Texas Education Agency, All rights reserved. 1.
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
Lecture 1: Safety and Protection. 1. A robot may not injure a human being or, through inaction, allow a human being to come to harm. 2. A robot must obey.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
EKT214 - ANALOG ELECTRONIC CIRCUIT II
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Frequency to Voltage Converter Used as RPM Gage
Overvoltage Protection, A. Zeddam, Dakar, Senegal, 25 March 2015 ITU Regional Standardization Forum For Africa Dakar, Senegal, March 2015 Overview.
Electrical Fundamentals
1 Version01_ TVS Diode Applications Training.
Overvoltage protection (surge arrester)
Calculating Separation Distance and Surge Current
Lesson 9: Electrical Components
Team Members: Advisor: Cruz, Jaime e. Dr. Paris Wiley
SFC UPSHAW POWER GENERATION EQUIPMENT Preventive Maintenance & Troubleshooting.
Surge Protection Devices
All rights reserved Surge Arrester.
Peter Brackett- Canadian Pacific Railway Robert MacMillan- CSX Railroad Earl Chapman – Railway Consultant, (previously CN) Keeping Signals Working What.
Instrumentation & Power Electronics
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
International Telecommunication Union ITU-T Study Group 05 The model testing/simulations Yasuhiro Honma Technical Session on Home Networks Geneva, 29/04/2011.
Introduction to switchgears
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
Electrical Installation II1 Assessment of General Characteristics (Note: All the mentioned tables in this course refer to, unless otherwise specified,
LIGHTENING PROTECTION USING LFA-M
EE 2353 HIGH VOLTAGE ENGINEERING Faculty Name :A.JAIBUNISHA Faculty Code : EE 58 Designation : LECTURER Department : EEE.
Power supply.
Design and Development of Transient Network Analyzer By M.Satish kumar 04131A0241 P.Sasi kumar 04131A0240 T.Sirisha 04131A0244 V.S.Pramod 04131A0247 Under.
Electrical Power II Unit 4-Overvoltages Unit 5-HVDC Unit 6-FACTS.
HNC/D Engineering Science
Automotive Heating And Air Conditioning
High Voltage Engineering
Surge Protection: Technical Background & Basics
Starting System Circuit Operation and Testing
SPD II 1 for LV Power (AC/DC)
Radio Base Stations Sited on Power Line Towers
Introduction to Electric Power System and A. C. Supply
Objectives Describe the introduction of a zener diode briefly
DC Generators.
High Voltage Engineering
Government Engineering College, Bhavnagar.
Connections Topology of Apollo ACS.
Kurt Uhlir President Standby Power System Consultants, Inc.
HIGH VOLTAGE ENGINEERING (HVE)
WELCOME TO ALL.
Unit 3 – Fundamentals of Electronics Examination Specifications
Basics of electrical engineering
THREE-PHASE GROUND-FAULT BASICS
OVER VOLTAGE The voltage waves having magnitude more than its normal value. In other words, sudden rise to an excessive or abnormal value It remains for.
Lightning Induced Surge
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Overcurrent Protection— Fuses and Circuit Breakers
Grounding System Design and Testing for Critical Facilities
LIGHTNING AND INSULATIONS COORDINATION
FIGURE 31-1 Internal construction of an oil-cooled ignition coil
Protection against over voltages
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
MAIDA DEVELOPMENT COMPANY Recommended Products for the Lighting Industry (757)
PowerLogic™ offer for the basic metering market
Parker domnick hunter. Safety of Electrical and
HIGH VOLTAGE ENGINEERING Presented By P.Sindhu Asst.Prof EEE Dept
Technical Background & Basics
Presentation On Schottky Diode. Course Code:3208 Course Title : Microwave radar and satellite communication lab Presented By Salma Akter BKH F.
Presentation transcript:

AC LIGHTNING PROTECTION Northern Technologies SA 411 JAN SMUTS AVE BLAIRGOWRIE 2024 E-MAIL : ntsa@mweb.co.za tel 787-3787 fax 787-3287 The Leader In Power Protection Systems CK966189823 NORTHERN TECHNOLOGIES SA cc AC LIGHTNING PROTECTION FOR TELECOM SITES Richard Paul Evans Northern Technologies SA PO Box 41342 Craighall 2024 South Africa Tel: +27 (011) 787 3787 Fax: +27 011) 787 3287

AUTHOR BIOGRAPHICAL NOTES RICHARD PAUL EVANS Qualified as a Communications Engineer specializing in mobile telecommunications at Telkom - South Africa’s parastatel telecommunications provider. Product specialist in power protection for 10 years. Technical Manager for Northern Technologies South Africa – a well known national leader in power protection.

ABSTRACT WELCOME TO OUR WORLD This paper will take you on a journey into the world of ac surge and lightning protection. We will attempt to take the “guess work” and “marketing hype” out of the subject, explore the different topologies commercially available and explain their method of operation, strengths and weaknesses. We will calculate what size transients can be expected and identify where and how to install ac surge protection in telecom installations, so as to ensure that the equipment is sufficiently protected. WELCOME TO OUR WORLD

ABSTRACT cont. Our goal is to provide you with a document which is practical and usable in the field for design purposes in terms of product comparison and selection of surge protection devices, as well as a maintenance tool to indicate where our existing facilities can be optimized. The key areas covered are: Topologies – different technologies commercially available, technical comparison. Modes of protection – explanation of modes and how to install surge protection devices. Criteria for selecting the correct topologies for telecom facilities. Correct application of class1 and class2 surge protective devices.

PROCESS OF SURGE ARRESTING Surge arresters can be viewed as a simple switch between two lines. When voltage rises as a result of a transient, the switch operates by diverting the energy away from our equipment. There will be a residual voltage left over. The amount of residual voltage is determined by the speed of the operation of the surge arrester - the faster the device operates the lower the residual voltage.

PROCESS OF SURGE ARRESTING \ Residual voltage or voltage protection level (VPL) Transient Live Surge Suppressor Diverted energy Equipment Neutral / Earth

TYPES OF SURGE ARRESTERS There are two types of surge arrester on low voltage AC systems – namely Class 1 and Class 2. The difference between them is their ability to divert energy in the form of a current.   Class 1 (Lightning Protection) Can divert energy with a current wave form of 10/350s – the rise time is 10s and the tail of wave is 350 s to 50% Typical current ratings 10Ka to 35Ka – 10/350s wave form. Class 2 (Surge Suppression) Diverts energy with a wave form of 8/20s – the rise time is 8s and the tail of wave is 350s to 50% Typical current ratings 5Ka to 200 Ka – 8/20s wave form.

CURRENT WAVEFORMS Current 10/350 Waveform 8/20 Waveform 8 ų SEC Time Microseconds

FOUR TOPOLOGIES COMMERCIALLY AVAILABLE Class 1 high energy MOV Class 1 gas discharge tube / air gap Class 2 SAD Class 2 MOV

CLASS 1 HIGH ENERGY METAL OXIDE VARISTOR (MOV) CLASS 1 GAS DISCHARGE TUBE/AIR GAP Electrodes or Cylinder Metal Oxide Block RT 100ns VPL 1500 - 4000V Current up to 25 Ka 10/350 for phase conductors RT 25ns VPL 1200V Current up to 35 Ka 10/350 Free air or gas Terminals ADVANTAGES DISADVANTAGES Rugged low incidents of failures Can handle high currents High tolerance for long over-voltage Slow – 100ns Follow on current can cause short circuit Poor protection level Degradation – deteriorates protection level and makes fault detection or indication difficult and unreliable High cost ADVANTAGES DISADVANTAGES Cost effective Fast – 25ns Low protection level Accurate fault indication Can degrade with time and use New Technology Can be sensitive to overvoltage

CLASS 2 SILICON AVALANCHE DIODE (SAD) CLASS 2 METAL OXIDE VARISTOR (MOV) Metal Oxide Block RT 25ns VPL 1000V Current up to 200 Ka RT 5ns VPL 500V Current up to 25 Ka HIGH ENERGY ZENER DIODE Terminals High energy zener diode ADVANTAGES DISADVANTAGES Low VPL <500V Fast –5ns Non degrading Life expectancy – 20 years High initial cost Limited current – up to 20 Ka ADVANTAGES DISADVANTAGES Low cost High current rating Slow – 25ns Thermally unstable Poor VPL 1000V+ Degradation – limited life

TOPOLOGY COMPARISONS CLASS 1 Parameters TOPOLOGY COMPARISON CLASS 1 Topology Gas tube / Air gap Class 1 High Energy Metal Oxide Varistor (MOV) Speed of operation 100 nano seconds – one hundreds billionths of a second 25 nano seconds – twenty five billionths of a second Residual voltage 2500 volts <1200 volts Current rating Up to 25K 10/350 Up to 35K 10/350 Degradation Degrades with use and time Lifespan Extremely limited – can fail after one day or after one transient. Extremely limited can fail after one day or after one transient. Types of transients with percentage of occurrence Lightning transients 40% Yes Surges 10% No Switching transients 50%

TOPOLOGY COMPARISONS CLASS 2 Parameters TOPOLOGY COMPARISON CLASS 2 Topology Silicone Avalanche Diode (SAD) Class 2 Metal Oxide Varistor (MOV) Speed of operation 5 nano second – five billionths of a second 25 nan seconds – twenty five billionths of a second Residual voltage <500 volts 1000 volts Current rating Up to 20ka 8/20 Up to 200ka 8/20 Degradation Non degrading Degrades with use and time Lifespan 20 years +++ Extremely limited can fail after one day or after one transient. Types of transients with percentage of occurrence Lightning transients 40% Yes Surges 10% No Switching transients 50%

VOLTAGE PROTECTION LEVEL The voltage protection level (VPL) refers to the residual voltage or clamping level of the arrester. The VPL of an arrester is directly related to the reaction time of the arrester ie: the faster the reaction time, the lower the VPL. In many cases, the transient is lower in voltage than the VPL of the arrester, or faster than the arrester’s reaction time. The arrester does not detect the transient and the transient damages the equipment. This is common with switching type transients which account for 50% of transients and are generated by inductive loads such as air conditioners, lift motors and standby generators - all of which are commonplace in most modern day facilities. The international electrical engineering spec (IEEE C62) clearly defines the level at which an arrester needs to operate in order to protect digital equipment. The following diagram illustrates this graphically, with reference to the different types of surge arresters commercially available.

VOLTAGE PROTECTION LEVEL Gas discharge tube or Air-Gap 2500V Transient / pike Voltage peak HARD FAILURE REGION Metal oxide varistor 1000V 800V DEGREDATION OR SOFT FAILURE REGION 600V SAFE REGION Silicon avalanche Diode 500V 240V Time Reference: IEEE C62

MODES OF PROTECTION There are two modes of protection: Common mode – (live to earth and neutral to earth) Most lightning transients are common mode and this refers to the live and neutral cables being at the same potential for that moment in time , and a potential difference ( transient voltage) being present between live /neutral and earth.   Normal mode\differential mode – ( live to neutral ) This refers to a potential difference (transient voltage) being super imposed onto the operating voltage. Digital power supplies such as computers, data switches, ups systems and telecom rectifiers draw their power in this area ie: draw current on the live conductor and return on neutral conductor, - this is their most sensitive area.

MODES OF PROTECTION cont. Most lightning protection systems fail to provide normal mode protection, which leaves the equipment in question unprotected. Note The voltage figures indicated , illustrate the effect of an induced transient of 10 000 volts in both common and normal/ differential modes.

L L N N E E MODES OF PROTECTON SPD SPD SPD Normal Differential Mode 10 000 VOLTS L L 10 240 VOLTS Normal Differential Mode SPD 240 VOLTS N N Common Mode 10 240 VOLTS SPD SPD E EARTH E

WHAT SHOULD THE CURRENT RATING OF THE ARRESTERS BE ? IEC 1024-1 refers.   Should transient with a design current with a minimum Ka rating of 100 ampere and a maximum Ka rating of 200 ampere strike a facility, 50% will travel to earth and 50% will be divided by conductors entering this particular facility. Worse case scenario: minimum rating of 12.5Ka and maximum rating of 25Ka

CURRENT CAPACITY OF INDUCED TRANSIENTS DESIGN CURRENT 100KA MIN 200KA MAX PHASE 1 PHASE 2 PHASE 3 NEUTRAL 50% EARTH Calculated current capacity MIN = 50/4 = 12.5KA MAX = 100/4 = 25KA REFERENCE: IEC 1024-1

CRITERIA FOR SELECTING CORRECT TOPOLOGIES FOR TELECOM APPLICATIONS First incoming point Class 1 rated at 10/350 current wave form. Minimum current rating 12.5Ka – maximum current rating of 25Ka Thermal disconnect with visual and remote annunciation. Modular for easy maintenance VPL 1200V Reaction time less than 25ns   Internal Distribution Point – input to rectifiers/ups/inverters Class 2 rated at 8/20 wave form. Thermal disconnect. VPL less than 600V Reaction time 8ns or less

AC SURGE PROTECTION SCHEMATIC FOR TELECOM SITE ◙ Aircraft warning light Sad/mov class 2 spd ○ ○ Class 1 High energy mov spd Antenna Ac  Internal db  External db   Container Class 1 High energy mov spd

CORRECT APPLICATION OF CLASS 1 AND CLASS 2 DEVICES Class 1 – Lightning protection to be installed in rural and exposed sites ie High Sites. Class 1 connection can be either TNS (L-E-N-E) OR TT (L-N N-E). One must ensure that grading is achieved through the distance between the distribution points or through the use of a grading device such as the Inductor Coil. Class 2 – to be installed on all sites. Class 2 device is always connected TT(L-N N-E).

References IEC 1024-1 IEC 61643-1 SABS 0142-1 National Wiring Code South Africa Motorola spec “ Transient over-voltage protection for telecom sites”