Maintenance schedule for different equipment and their records in a hospital By Mr. Rahul kumar.

Slides:



Advertisements
Similar presentations
Safety Testing of Medical Electrical Equipment
Advertisements

Electrical Safety BiomedE / EECS 458 Reading: Webster, Chapter 14.
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
By: Aseem Aggarwal. Causes of Electrocution Fatalities Contact with Overhead Power lines Contact with Live Circuits Poorly Maintained Extension Cords.
OSHA Office of Training and Education
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Electrical Safety Safety Unit Lesson 6. Electricity Electric shock from welding and cutting equipment can kill or cause severe burns by coming in contact.
Chapter 14. Electrical Safety Walter H. Olson
Electricity. فيز 101 : محاضرة رقم 7: فيز 101 : محاضرة رقم 7: الكهرباء.
Electrical Safety of Medical Equipment
OSHA Office of Training and Education
Principles of Biomedical Systems & Devices
Union College EHS Training 1 Electrical. 2 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical.
Biomedical Instrumentation I
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Physiological Effects of Electricity on Human Body by Mohd Yusof Baharuddin.
Safety Training For The Non-Qualified
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
Area of Study 2: Electricity
Chapter 14. Electrical Safety Walter H. Olson
Electrical Safety INSTRUCTOR’S NOTES:
Electrical This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are.
Electrical Safety INSTRUCTOR’S NOTES:
1 Electrical Safety. 2 Electrical Hazards & OSHA 29 CFR (b)(1) requires: “Electrical equipment shall be free from recognized hazards that are.
Electrical Safety INSTRUCTOR’S NOTES:
Communication Signals Electrical Safety Fox Valley Technical College Appleton, WI, USA.
HAZARD OF MEDICAL INSTRUMENT by Mohd Yusof Baharuddin.
Chapter 20, Section 4 Electrical Safety Wednesday, January 20, 2010 Pages
Ferris State University & Michigan Department of Career Development 1 Electrical Safety.
Basic Electrical Safety
BEAMLINE for SCHOOLS – East Area ELECTRICAL HAZARDS SAFETY 11 th September 2015 HSE Unit 1.
HAZARD OF MEDICAL INSTRUMENT II by Mohd Yusof Baharuddin.
Static Electricity Videos r1LYXY NQg.
DEVICES TO PROTECT AGAINST ELECTRICAL HAZARDS
Electrical Safety Safety Unit Lesson 6. Electricity Electric shock from welding and cutting equipment can kill or cause severe burns by coming in contact.
ELECTRICAL SAFETY OUTLINE  The basic effect of electricity on human body  Ventricular Fibrillation  Electric shock  Electric Shock – Treatment  Important.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Physics 106 Lesson #17 Home Wiring
Current Electricity is the rate at which charges pass a given point. The higher the current is the greater the number of charges pass the point each second.
EE 4BD4 Lecture 22 Electrical Safety Electrode on Skin 4.
 A medium that provides a means for transferring energy from one place to another  It is not expensive or difficult to control the risk of an electrical.
© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 14.1 Physiological effects.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
ELECTRICAL SAFETY in the Lab. 1.Electricity takes the path of least resistance. 2.Electricity wants to go to ground. 3.If an electrical appliance or tool.
BASIC ELECTRICAL SAFETY. INTRODUCTION PURPOSE: To provide employees with safe work practices & procedures to prevent an electrical accident or injury.
Ground Faults Done By : - Anas Atallah - Moatasem Tareq.
Electrical Safety and Safe Work Practices
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
PROTECTION AGAINST INDIRECT CONTACT
Circuit Protection Unit 9.
Grounding And Safety Techniques Ms. Tahoora Qureshi, Asst. Professor
Biomedical Instrumentation
Basic Electrical Safety
ELECTRICAL SAFETY FOR MEDICAL EQUIPMENT By m.naga sundhari
WELCOME TO ALL.
Subpart K Electrical Long recognized as a serious hazard.
Instructor: Sujood Alazzam
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Practical electricity
Electrical Safety Review Compliance Assistance Region IV
Electrical Safety in the Home
Diathermy and its safe use
ELECTRICAL DISTRIBUTION SYSTEMS IN HOSPITAL
FYS 4250 Kap.14 Electrical safety.
Basic Electrical Safety
Basic Electrical Safety
Basic Electric Principles
2008 Code Drills Health Care Facilities
Presentation transcript:

Maintenance schedule for different equipment and their records in a hospital By Mr. Rahul kumar

 Most commonly used electric equipments in the hospitals are : Computers Refrigerators Cardiac monitors Pulse oxymeter Nebulizer Syringe pump Glucometer Ultrasound CT & MRI machines Ventilator Defibrillator  Proper care and maintenance is very important for proper functioning of equipment.

Physiological effects of current

Ventricular fibrillation In cases of shock due to unwanted connection to power grid voltage, current passing through the heart is considered the most dangerous effect and can cause ventricular fibrillation (ventricles) with fatal consequences Ventricular fibrillation is completely irregular, asynchronous heartbeat; no synchronism in ventricular contractions, blood flow stops and if such heart work does not stop, it leads to death within a few minutes

 Body weight and fibrillation, duration of the current Several studies using animals of various sizes have shown that the fibrillation threshold increases with body weight Fibrillating current increases from 50 mA rms for 6 kg dogs to 130 mA rms for 24 kg dogs.

Leakage currents Occur between conductors that are not in direct contact (touch) and are at different potentials For devices that are powered from the grid, leakage currents are: – capacitive character (spreading capacity) – operative character (current through the insulation, dust, humidity...)

Leakage currents

Leakage currents pathways Pathways of leakage current through the patient a) Intact ground lead b) Broken protective ground lead, patien connected to ground through a catheter c) Broken protective ground lead, patien connected to ground by an electrode or unintentianally.

Point of entry (macroshock and microshock) Microshock:- Macroshock:- All the current applied through an intracardiac catheter flows through the heart small currents called microshocks can induce Ventricle fibrillation Current of about 20 µA can cause microshock. The widely accepted safety limit to prevent microshocks is 10 mA. When current is applied at two points on the surface of the body, only a small fraction of the total current flows through the heart (macroshock). The magnitude of current needed to fibrillate the heart is far greater when the current is applied on the surface of the body than it would be if the current were applied directly to the heart

Isolated-power systems Any ground faults can posses hazard. A ground fault :- Is a short circuit between the hot conductor and ground that injects large currents into the grounding system.  Isolation of both conductors from ground is commonly achieved with an isolation transformer isolation transformer + line isolation monitor Measures the total possible resistive and capacitive leakage current (total hazard current) that would flow through a low impedance if it were connected between either isolated conductor and ground. When the total hazard current exceeds 3.7 to 5.0 mA for normal line voltage, a red light and an audible alarm are activated Checking the lines by the LIM can interfere with (ECG,EEG,ect.),or it can trigger synchronized defibrillators

Limits on Leakage Current Limits on Leakage Current for Electric Appliances

Basic approaches to protection against shock Reliable grounding for equipment Reduction of leakage current Double-insulated equipment Operation at low voltages Electrical isolation There are two fundamental methods of protecting patients against shock:- 1. The patient should be completely isolated and insulated from all grounded objects. 2. All sources of electric current and all conductive surfaces within reach of the patient can be maintained at the same potential, which is not Isolated heart connections  For the power distribution For the equipment necessarily ground potential  In practical neither of these approaches can be fully achieved so we used :-  Grounding system  solated pow distribution system  Groun fault circuit interrupters (GFCI)

Protection: power distribution Grounding system - A grounding system protects patients by keeping all conductive surfaces and receptacle grounds in the patient ’s environment at the same potential The grounding system has 1. a patient-equipment grounding point 2. a reference grounding point 3. and connections

Isolated-power systems A ground fault :- Is a short circuit between the hot conductor and ground that injects large currents into the grounding system.  Isolation of both conductors from ground is commonly achieved with an isolation transformer isolation transformer + line isolation monitor Measures the total possible resistive and capacitive leakage current (total hazard current) that would flow through a low impedance if it were connected between either isolated conductor and ground. When the total hazard current exceeds 3.7 to 5.0 mA for normal line voltage, a red light and an audible alarm are activated Checking the lines by the LIM can interfere with (ECG,EEG,ect.),or it can trigger synchronized defibrillators

Protective grounding Generally, patients are only occasionally and accidentally exposed to risk of getting in touching with devices whose conductive parts may be energized In hospitals, especially in intensive care units, patients are deliberately connected to the diagnostic and/or therapeutic electrical devices/equipment – particularly careful with the isolation of any conductive parts connected to the heart or its vicinity from all other conductive parts – all conductive parts in the vicinity of the patient must be connected to a single point grounding (eg, metal bed, cupboard, etc.) – periodic testing of the grounding impedance must be provided Tolerable difference in potential between the grounded conductive parts in clinical areas: – in the general - of 500 mV – intensive care and other critical cases- of 40 mV

Determination of device categorie