Construction Section Requirements.

Slides:



Advertisements
Similar presentations
Bedridden Code Issues in RCFE’s Working with Your Local Fire Authority
Advertisements

CERTIFIED LEAD-BASED PAINT RENOVATION CONTRACTOR License Requirements & Work Practice Standards.
Architectural Drawing
Classroom Safety. Fire & Life Requirements as per State Education Dept The following list relates to the classrooms and adjacent areas. They are provided.
7 | Means of Egress (Life Safety Code)
Residential Building Codes and Preferences For the Designer Sleeping Area Architectural Design.
Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Architectural Design Copyright Texas Education Agency (TEA) 1.
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
Guidelines and Required Codes That Affect Building Design
Farmworker Housing Inspections Unit 3: Conducting the Inspection.
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
Community Living Arrangement (CLA)
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
The House as a System 1. Air Temperature and Water Vapor.
SOUTH CAROLINA’S FIRE PROBLEM: South Carolina Office of State Fire Marshal Public Fire Education and Data Management South Carolina Office of State Fire.
Quality Management – Cost and Time Management Initial Cost of Materials & Equipment Labor Cost Long Term Cost Time Management.
Division of Child Care STARS Interim Report. What is an interim report? Programs participating in the STARS for KIDS NOW program must demonstrate continued.
Application for Approval of Funding for Residential Placement
 Receive an Approval Letter from DIDD Provider Enrollment Coordinator.  Contact per letter’s instructions, Julia Jinnette by phone, or letter.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Massachusetts Department of Public Health Bureau of Environmental Health Heating Systems and Enforcement of the Housing Code (In conjunction with the Department.
Child Care Fire Safety Program North Carolina Fire Prevention Code 2000 International Fire Code with NC amendments. North Carolina Building Code Council.
Emergency Action Plans
EGRESS AND FIRE PROTECTION
Road Map to a Green Tag Paperwork=Time=Money. Questionnaire If you could change any one major thing inside the Fire Community Services process what would.
Business Owners and Managers and the Fire Code
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
FHA 203K IS ONE LOAN FOR A PURCHASE OR REFINANCE, THAT ALSO FINANCES HOME IMPROVEMENTS. WHILE THE FHA 203K HAS MANY ADVANTAGES, ITS PRIMARY BENEFIT IS.
1 MEDI-CAL CERTIFICATIONS & RE-CERTIFICATIONS (General Overview) Mental Health Services Division Compliance Section Certification & Questionable Medi-Cal.
Building Codes and Interior Design
Farmworker Housing Inspections Unit 2: Pre-Inspection Preparations.
Week 3. Electrical Code 1. all electrical outlets run off a pigtail from main line 2. Each Circuit is wired directly into circuit panel - no junction.
Updated Space Heater Policy For Weatherization -- Draft National Weatherization Training Conference Orlando, FL December 10, 2007.
Building Codes Intended to protect the public by establishing minimum standards of building safety.
Fire Inspection and Code Enforcement, 7 th Edition Chapter 4 — Construction Types and Occupancy Classifications Inspector I.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.
MONTGOMERY COUNTY FIRE & RESCUE FAMILY CHILD CARE FIRE SAFETY NOTEBOOK Written By: M/FF Matt Kelleher 2008.
Radon 101 and Radon Testing Do’s and Don'ts Alton, Illinois October 23, 2015.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Code Officials and the Code Process.  Concentrates on the code process as a whole.  Different type of code officials  Various steps that are taken.
Children System of Care Application Process for Behavioral Assistance & Intensive In-Community Department of Children and Families, Children’s System.
Services Currently Provided  FHA/ADA Inspections  Bank Draw Requests  Existing Condition Documentation Services.
Permit Process & Application Guide
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
“My Room” Project The Massachusetts Code Book and the rules that apply.
What are the DCC-413 and DCC-414 and how do they pertain to me? The STARS Interim Report.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Flammable Liquids Directorate of Training and Education
Drafting 2 (Arch) Quiz Review #3 Quiz Review. 1.Dashed lines that follow the counters in a kitchen floor plan most likely represent: A dishwasher Upper.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Routine Inspections 1 1.
CITY OF HARARE EMERGENCY SERVICES
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Understanding “Licensed Capacity” in Family Care Homes
Electrical Receptacle Testing
Chapter 19 Electrical Plans.
General Requirements of NFPA 101
Architectural Drawing
Building standards Mr. Da Silva.
PROPOSED AMENDMENTS TO marijuana regulations
Presentation transcript:

Construction Section Requirements

PLEASE READ YOUR RULES The overall Physical Plant Rules for Mental Health are outlined under 10A NCAC 27G Section .0300. Certain programs have additional physical plant rules. If you are operating under one of those programs those rules as well as the overall physical plant rules will apply or in some cases may supersede certain aspects. These rules in conjunction with the current NC Building Codes establish how surveys are conducted. The Construction Section will not make any site visits until the construction fee is paid. We urge you to contact us at 919-855-3893 and ask for a MHL surveyor with any questions concerning construction requirements.

How The Survey is Set Up: PROVIDER’S RESPONSIBILITIES Completely fill out Page 10 of 29, then sign and date the application. Page 14 & 15 of 29 lists the Service Categories. Check your category and the number of beds desired. The construction invoice outlining the appropriate fee must be returned and paid in advance of the initial survey. Accurate contact information must be provided to facilitate setting up your survey. Include in your application a floor plan with locations of smoke detectors. Provide the Construction Section with an email address and working phone number. Know the difference between Ambulatory and Non- Ambulatory and check the appropriate space.

How The Survey is Set Up: CONSTRUCTION’S RESPONSIBILITIES After your application is submitted to Licensure, it is reviewed and forwarded to the Construction Section. The application and its contents are verified by Construction. Construction verifies your application, assigns a project number and sends you an acknowledgment letter along with a construction invoice. The construction invoice outlining the appropriate fee must be returned and paid before the initial survey can be done. The survey will be scheduled 3-4 weeks after payment is received The individual listed on the application as the contact person will be notified to schedule the survey, so accurate information must be provided.

How The Survey is Set Up: CONSTRUCTION’S RESPONSIBILITIES Upon completion of the survey, we will sit with you and discuss any deficiencies that must be corrected. DHSR-Construction will send you a Statement of Deficiencies document that you must sign and return to us stating the corrections are completed. DHSR-Construction will verify the deficiencies are corrected either through another site visit or by submitted documentation. When all deficiencies are corrected, a letter is sent informing you that your facility has been recommended for licensure.

Applicable Building Code Items: What We Look for During the Survey Smoke Detectors One 120 –volt smoke detector permanently connected to the house current. Interconnected; installed in each bedroom; installed outside of any bedroom or cluster of bedrooms; installed on each story of the home including the basement if habitable. Ground Fault Interrupter Protection Along countertops, in Garages, outdoor outlets, and Bathrooms

Applicable Building Code Items: What We Look for During the Survey Kitchen Range Hood Vented to the outdoors or if its an unvented hood with an approved charcoal filter; there is no MHL rule requirement for a range hood, but the home must meet 10A NCAC 27G .0303(4)(c). charcoal filter Bathroom Ventilation Not required unless there is no window. If installed it must be vented to the outside of the home not into the attic

Applicable Building Code Items: What We Look for During the Survey Clothes Dryer Non-combustible metallic flex duct vented to the OUTSIDE of the home connected to a backdraft Water Temperature Between 100 degrees and 116 degrees

Applicable Building Code Items: What We Look for During the Survey Interior Finish Any wood paneling must be treated with an approved fire retardant paint and must meet a minimum Class ‘C’ or greater flame spread. If mill lumber with Varnish is present in the home it must also be treated. (Does not include knotty pine or cabinets). wood paneling Railings Porches, balconies or raised floor surfaces that are 30” or more above grade must have guardrails not less than 36” in height.

Applicable Building Code Items: What We Look for During the Survey Emergency Egress Every sleeping room must have at least one operable window OR an exterior door that is approved for emergency egress. Current code requires sill heights not more than 44” above the floor. Homes built under the 1968 residential building code may be allowed a minimum 48” above the floor. Minimum window height shall be 22” and minimum window width is 20”.

Applicable Building Code Items: What We Look for During the Survey Minimum Ceiling Height Residential ceiling heights must be no less than 7 feet for every room in the house. All ceiling heights not less than 7’-0” Discharge Relief Valve The discharge relief valve should terminate no less than 6” above the floor and may be piped to the outside of the home or piped to a drain pan (must not terminate under the home). Acceptable piping is CPVC or Copper only.

Applicable Building Code Items: What We Look for During the Survey 2-Story Homes – Remote Exit If the home is requesting 4 to 6 clients or if the home is a two story dwelling, the home must meet the requirements of Section 421.2.1 which states that each normally occupied story of the facility shall have two remotely located exits

Applicable Building Code Items: What We Look for During the Survey Bedrooms a) Single occupancy bedrooms a minimum of 100 square feet b) Double occupancy bedrooms a minimum of 160 square feet c) 3 residents 3 residents you must meet the residential building code d) 4 but no more than 6 residents 4 to 6 residents you must meet requirements of Section 421.2 of the NCSBC Providers may request an Equivalency if the bedrooms do not meet the required square footage. Equivalency request for single occupancy – no less than 95 sq. ft. Equivalency request for double occupancy – no less than 155 sq. ft. Any space in a bedroom that is deemed unusable space cannot be included in a bedroom’s square footage.

Approved Fire Retardants: Must meet minimum “Class C” fire resistance Flame Control - Fire Retardant Paint Contact: Flame Control Coatings, LLC Phone: 716-282-1399 FR-1 - Fire Retardant Paint Additive for Water Based Latex Paints Contact: Project Fire Safety, Inc. Phone: 800-468-2876 Flame Guard - Fire Retardant Treatment for Water Based Latex Paints Contact: Hy-Tech Thermal Solutions Phone: 321-984-9777 The listed paints or additives may be purchased from your local paint dealer, hardware store, or you may search online to locate a dealer who sells the product. After your purchase maintain copies of your receipts as verification of your purchase. We Accept NO Substitutes

Manufactured and Modular Home Use Within the MHL Program Manufactured Homes may serve three or fewer residents including occupants of the facility that require care by the caregivers. Manufactured Homes may be licensed under .5600 Supervised Living or .5100 Community Respite Services programs only. Modular Homes may serve any program as they are classed as Single Family Residential. Manufactured Homes and Modular Homes still require the approvals from the local jurisdictions.

Manufactured and Modular Home Use Within the MHL Program How Manufactured Homes are Identified HUD Certification Label for Manufactured Homes This label is the manufacturers certification that the home was manufactured in accordance with HUD’s Construction and Safety Standards that were in effect at the time the home was manufactured.

Manufactured and Modular Home Use Within the MHL Program How Modular Homes are Identified North Carolina Validation Stamp for Modular Homes This label and the Building Manufacturer’s Data Plate certifies the structure has been manufactured and inspected in accordance with the North Carolina’s inspection requirements. The Validation Stamp usually is located in the cabinet above the range hood.

Permits and Approvals All required building permits and final approvals must be obtained from the local authorities having jurisdiction. The required approval forms must come from the local authorities, but they may require you to have forms provided by Construction. DHSR-Construction must have the following inspection forms before a recommendation for licensure is made: Small Home Building Approval Form (DHSR-Construction form) or If you receive a Certificate of Occupancy or any approval from the local building official it must state the facility meets Section 421.2 of the current NCSBC Fire & Building Safety Inspection Report (DHSR-Construction form) NC Division of Environmental Health form “Inspection of Residential Care Facility” (NCDENR form 2094) NO INSPECTIONS UNTIL WE HAVE COMPLETED OUR SURVEY!!

NC State Building Section 421: Licensed Residential Care Facilities 421.1 Classification. Buildings in which more than three people are harbored for medical, charitable or other care or treatment shall be classified as Residential Care Facilities. The State Agency having jurisdiction shall classify the facility as a Residential Care Home, Small Residential Care Facility, Small Non-Ambulatory Care Facility or Large Residential Care Facility. 421.1.1 Fire extinguishers shall be installed in Licensed Residential Care Facilities in accordance with the North Carolina Fire Prevention Code. 421.1.2 Where two exits are required, the exits or exit access doors shall be so located and constructed to minimize the possibility that both may be blocked by any one fire or other emergency condition. 421.2 Residential Care Homes. Homes keeping no more than six adults or six unrestrained children who are able to respond and evacuate the facility without assistance, determined by the State Agency having jurisdiction to be licensable, shall be classified as Single Family Residential (North Carolina Residential). 421.2.1 Each normally occupied story of the facility shall have two remotely located exits. 421.2.2 Smoke detectors shall be provided on all levels per the North Carolina Residential. 421.2.3 Interior wall and ceiling finish shall be Class A, B or C. 421.2.4 Unvented fuel-fired heaters and portable electric heaters shall not be used.

FREQUENTLY ASKED QUESTIONS Below are a Number of Questions Routinely asked Regarding the Construction Process 1) What are my options if my bedrooms don’t have the required square footage? You may request an equivalency in writing addressed to the Chief of Construction based on the recommendation of the surveyor. Reference the Applicable Building Code Items in this handout for guidelines. 2) If I have a second story will I be required to install an exterior exit at that location? Yes. If you have four or more residents or if the upstairs will be used as office space. 3) Will a handicap ramp be required? Yes, if you provide services for a non-ambulatory resident. Also, some local jurisdictions require ramps regardless of program, the type of home it is or the number of residents that will occupy the facility. 4) Can Construction survey my facility before I submit my application? No. You will be invoiced by Construction. Once that fee has been paid Construction will make an onsite survey visit to your facility. 5) What is a Non- Ambulatory resident? Any resident who is NOT able to evacuate the facility without verbal or physical assistance.

FREQUENTLY ASKED QUESTIONS Below are a Number of Questions Routinely asked Regarding the Construction Process 6) What is an Ambulatory resident? Any resident who IS able to evacuate the facility without verbal or physical assistance. 7) Are my residents allowed to smoke in my facility? House Bill 1294 Section 3, Article 1 of Chapter 122C of the General Statues was amended to read “Smoking prohibited; penalty”. In essence, smoking is not allowed inside the facility by any person living or employed at such location. 8) Can a resident access a bedroom through another resident’s bedroom? No. Access to residents’ bedrooms cannot be through another room being occupied by a resident as a bedroom. 9) If I don’t have built-in closets can it still be used as a bedroom? Yes, but wardrobes must be added. 10) Am I required to have a fire retardant on my interior walls? If the walls have wood paneling they must be treated with an approved* fire retardant paint unless documentation is provided that verifies the finish is a Class C or higher. Knotty Pine, mill lumber with no varnish finish is acceptable. If mill lumber has varnish it must be treated.