Total implantation of the implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss  Hans Peter Zenner, MD, Hans Leysieffer,

Slides:



Advertisements
Similar presentations
Figures for Chapter 9 Prescription
Advertisements

Real-ear Measurements with the A-35
RECD Refresher Course 17th November 2004 In Situ Versus Coupler Verification Working Smarter ! Ed Brown Consultant Audiological Scientist MCHAS University.
M.Sc. in Medical Engineering
ANSI Overview Hearing Aid Testing and Verification What is ANSI?
TOPIC 4 BEHAVIORAL ASSESSMENT MEASURES. The Audiometer Types Clinical Screening.
PURE TONE AUDIOMETRY BALASUBRAMANIAN THIAGARAJAN DRTBALU'S OTOLARYNGOLOGY ONLINE.
Introduction to the FONIX 7000 Hearing Aid Test System Software version 1.60.
Nick Hamilton EE April 2015 Abstract: When natural hearing is lost, cochlear implants provide an opportunity to restore hearing. These electronic.
Cochlear Implants Andrew Rosenberg
Audiology Training Course ——Marketing Dept. Configuration of the ear ① Pinna ② Ear canal ③ Eardrum ④ Malleus ⑤ Incus ⑥ Eustachian tube ⑦ Stapes ⑧ Semicircular.
Amplification/Sensory Systems SPA 4302 Summer 2007.
Amplification systems: Hearing aids May be analog or digital May be analog or digital Consists of a microphone, amplifier, and loudspeaker. Consists of.
Figures for Chapter 6 Compression
Bone Anchored Hearing Aids Dr. Amir Soltani Clinical Audiologist UBC Resident Otology Lecture Series BC Children Hospital Sep 13, 2013.
Esteem Hearing Implant Andrew Dunne. What is Esteem?  A totally implantable hearing system that is implanted under the skin behind the ear and within.
Super Power BTE A great new Trimmer Family. The new & complete, fully digital Trimmer family ReSound is proud to introduce the complete new trimmer family,
Acoustic and Implant Driven Vibrations of the Round Window Jonathan H. Spindel 1, Richard L. Goode 2, Alex Huber 3, Geoffrey Ball 4 Department of Integrated.
METHODOLOGY INTRODUCTION ACKNOWLEDGEMENTS LITERATURE Low frequency information via a hearing aid has been shown to increase speech intelligibility in noise.
Figures for Chapter 1 Introductory concepts
ANATOMY AND PHYSIOLOGY OF THE EAR
Chapter 5: Normal Hearing. Objectives (1) Define threshold and minimum auditory sensitivity The normal hearing range for humans Define minimum audible.
Need for cortical evoked potentials Assessment and determination of amplification benefit in actual hearing aid users is an issue that continues to be.
Cochlear Implantation at King Abdullaziz University Hospital, Riyadh: A Multisystem Prgram, ( )
CSD 5400 REHABILITATION PROCEDURES FOR THE HARD OF HEARING Amplification Implantable Hearing Aids Cochlear Implants.
AUDIOLOGY IN ORL DR. BANDAR MOHAMMED AL- QAHTANI, M.D KSMC.
1 Chapter 32 Hearing Loss in Osteogenesis Imperfecta Copyright © 2014 Elsevier Inc. All rights reserved.
AUDIOMETRY An Audiometer is a machine, which is used to determine the hearing loss in an individual.
Hearing. Anatomy of the Ear How the Ear Works The outer ear The pinna, which is the external part of the ear, collects sounds and funnels them through.
The Child with Hearing Loss Bradley W. Kesser, MD Otolaryngologic Clinics of North America Volume 48, Issue 6, Pages xv-xvi (December 2015) DOI: /j.otc
INTRODUCTION TO AUDIOLOGY (SPHS 1100) WEEK 6 POWER POINT TOPICS  TREATMENT OF CONDUCTIVE HEARING LOSS  TREATMENT OF SENSORINEURAL HEARING LOSS  TECHNOLOGY.
Date of download: 6/22/2016 Copyright © 2016 American Medical Association. All rights reserved. From: The Clinical Value of the Multiple-Frequency 80-Hz.
How we DON’T Hear Types of Hearing Loss, How they Happen, and What can be Done about Them.
Artificial Cochlear Implants Geoff Norman 4/18/16
COCHLEAR IMPLANTS INSERVICE.  Middle Ear  Hammer  Anvil  Stapes How the ear works  Outer Ear  Inner Ear  Cochlea  Auditory Nerve.
HEARING LOSS.
A COMPARISON OF wRECD AND RECD VALUES AND TEST-RETEST RELIABILITY
Hearing Loss and Hearing Aid Treatment Options
Hearing aid silicone impression material as a foreign body in the middle ear  Hyun-Min Lee, MD, Keun-Ik Yi, MD, Jae-Hoon Jung, MD, Il-Woo Lee, MD, PhD 
Trina Redford, Industrial Hygienist National Naval Medical Center
Copyright © American Speech-Language-Hearing Association
Rehabilitation of Hearing Impaired Individuals
Therapeutic equipment I
Unit 1.3 Review MI.
ANATOMY THE EAR Dr. J.K. GERALD, (MD, MSc.).
Physics of hearing.
ANATOMY AND PHYSIOLOGY OF THE EAR
A.3 Perception of Stimuli
Copyright © American Speech-Language-Hearing Association
Fig 2. Arrow indicating obliteration of the oval window
Radiation Therapy and Hearing Loss
Section 14.3 Hearing and Equilibrium
Neurology of The Ear.
Journal#5: What would happen if you were born without cones
ANATOMY AND PHYSIOLOGY OF THE EAR (HEARING)
Hearing Loss and Hearing Aid Treatment Options
Structure and function of the eye
Human hearing Limits, the human ear, and issues of perception
Wei Dong, Elizabeth S. Olson  Biophysical Journal 
Nervous System Ms. Doshi.
Sound in the Ear Presentation
ANATOMY AND PHYSIOLOGY OF THE EAR
Carotid endarterectomy significantly improves postoperative laryngeal sensitivity  Georg Philipp Hammer, MD, Peter Valentin Tomazic, MD, Sarah Vasicek,
Analysis of Dynamic Brain Imaging Data
The ear.
Julien Meaud, Karl Grosh  Biophysical Journal 
Role of Ca2+ and Cross-Bridges in Skeletal Muscle Thin Filament Activation Probed with Ca2+ Sensitizers  Philip A. Wahr, Joseph M. Metzger  Biophysical.
Electroacoustics Prof. Andrzej Dobrucki, PhD Maurycy Kin and Prof. Krzysztof Opieliński The chair of Acoustics and Multimedia, Wrocław University of Science.
Therapeutic equipment I
Presentation transcript:

Total implantation of the implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss  Hans Peter Zenner, MD, Hans Leysieffer, PhD  Otolaryngologic Clinics of North America  Volume 34, Issue 2, Pages 417-446 (April 2001) DOI: 10.1016/S0030-6665(05)70340-6 Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 1 TICA (Implex, Munich, Germany) components. Piezoelectric actuator (A) with rod for coupling to the incus body and clip (B) for coupling to the long incus process. C and D, Membrane sensor with retention collar. Actuator and sensor possess plugs to be inserted into the (E and F) main module with digitally programmable 3-channel audio-processor. Note pressure connector assembly (PCA) opened for sensor and actuator plugs. G, PCA closed. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 2 Actuator displacement (XS) versus frequency in a no load condition (insert) using laser doppler vibrometry. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 3 Estimated equivalent sound pressure level. Equivalent sound pressure level (SPL) was estimated for the actuator at maximum driving voltage (1.0 VRMS). Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 4 Actuator displacement under load. Displacement (Xs) versus frequency in a simulated middle ear coupling condition. The insert shows the invitro coupling condition using an artificial ossicle made of stiff Silastic. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 5 Actuator displacement in the presence of load and friction. Displacement (Xs) versus frequency in the same coupling condition as shown in Figure 3. In this case the influence of possible tissue growth around the coupling area to the ossicles was simulated by using a little drop of silicone grease (insert). Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 6 Nonlinear distorsion of the actuator. Experiments were performed using contactless laser doppler vibrometry in the in vitro simulation corresponding to Figure 3. The transducer was driven with a sinusoidal voltage at 1000 Hz and 1.0 VRMS. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 7 Temporal resolution of the actuator. A, Actuator driven with an electrical unipolar pulse of 100 μs of 1.4 Vpeak. Impulse response was measured using laser doppler vibrometry. B, Transducer response in a mechanical no load condition (compare with Figure 2). C, Impulse response corresponding to the mechanical load simulation of Figure 3. D, Impulse response corresponding to the load condition as in Figure 4. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 8 Frequency response of the sensor with the membrane covered by skin. Experiments were performed in an acoustic free-field condition. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 9 Directional characteristic of the sensor. Sensor was positioned in an artificial ear canal of a KEMAR head (right). Directional characteristic of the KEMAR® head using a standard 2 ccm coupler (left). Frequencies: line = 1 kHz; dashed line = 2 kHz; dotted line = 4 kHz. Measurements were done in an unechoic chamber in free-field conditions. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 10 Stapes displacement. Qualitative frequency response of the stapes displacement (Xs) in a fresh temporal bone with transducer coupling to the incus body. The displacement measurement was done using a contactless laser doppler vibrometer centered on the stapes footplate through an intracochlear access from the cranial side. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 11 Sensor implanted in a fresh temporal bone. This situation was used for determination of acoustic free-field frequency response in Figure 12. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 12 Acoustic free-field frequency response of the sensor. Sensor was implanted in a fresh temporal bone (see Fig. 11). Lmik = 0 dB corresponds to a sensor sensitivity of 3 m V/Pa. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 13 Human studies. A, Phase I study. B, Acute study during tympanoplasty. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 14 Clinical TICA implant according to Leysieffer-Zenner. A, Coupling to long incus process. B, Coupling to incus body and optional reversible malleus neck dissection (reversible malleus neck dissection (RMND), Fig. 16). C, Implant with actuator (right), sensor (top) and main module (includes battery and microprocessor). D, Radiograph of TICA implanted in a patient. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 15 Surgical procedure. A, Coupling to the long incus process. B, Insertion of membrane sensor. C, Coupling to incus body. D, Final view of implant coupled to incus body. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 16 Reversible malleus neck dissection (RMND). May be performed using a CO2 laser (Sharplan, Tel Aviv, Israel). RMND may be restored using a drop of liquid cement (From Zenner et al, 2000; with permission). Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 17 Postoperative care. A, Microscopy of external auditory canal. B, Telemetrical fitting of the implant using a PC-based adjustment software. C, Wireless, battery-driven remote control for the patient. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 18 Results of prospective clinical study (n = 20). A, Functional gain (difference of postoperative unaided and aided binaural free-field thresholds) with TICA programmed for a most comfortable setting (n = 19 patients). Thin line = median values and interquartile ranges; Thick line = maximum functional gain. B, Six months' postoperative speech discrimination results using a monosyllabic test (Freiburg test), n = 19 patients, median values and interquartile ranges. C, Spatial hearing: left column shows correct answers, right 3 columns show errors. D, Quality of life evaluation (Gothenburg profile) for the preoperative unaided, preoperative aided (conventional hearing aids) and postoperative aided (TICA) condition. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 18 Results of prospective clinical study (n = 20). A, Functional gain (difference of postoperative unaided and aided binaural free-field thresholds) with TICA programmed for a most comfortable setting (n = 19 patients). Thin line = median values and interquartile ranges; Thick line = maximum functional gain. B, Six months' postoperative speech discrimination results using a monosyllabic test (Freiburg test), n = 19 patients, median values and interquartile ranges. C, Spatial hearing: left column shows correct answers, right 3 columns show errors. D, Quality of life evaluation (Gothenburg profile) for the preoperative unaided, preoperative aided (conventional hearing aids) and postoperative aided (TICA) condition. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 19 Results of patients selected according to the criteria in Figure 20. A, Functional gain (difference of postoperative unaided and aided binaural free-field thresholds) with TICA programmed for a most comfortable setting. Thick line = median values and interquartile ranges; thin line = maximum functional gain. B, Threshold transfer into long-term speech spectrum. C, Word recognition. D, Gothenburg profile before and after surgery. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 19 Results of patients selected according to the criteria in Figure 20. A, Functional gain (difference of postoperative unaided and aided binaural free-field thresholds) with TICA programmed for a most comfortable setting. Thick line = median values and interquartile ranges; thin line = maximum functional gain. B, Threshold transfer into long-term speech spectrum. C, Word recognition. D, Gothenburg profile before and after surgery. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions

Fig. 20 Indications for TICA LZ 3001. Moderate to severe high frequency SNHL up to 90 dB at ≥3 kHz. Maximum low frequency hearing loss should be no more than 30 dB at 0.5 kHz. In addition, the slope of hearing loss between 0.5 and 2 kHz should be 30 dB and more. Missing benefits from conventional hearing aids include medical problems, psycho-social problems, audiologic problems, professional problems. Mastoid with normal pneumatization. Otolaryngologic Clinics of North America 2001 34, 417-446DOI: (10.1016/S0030-6665(05)70340-6) Copyright © 2001 W. B. Saunders Company Terms and Conditions