Deploying the Aorfix AUI Converter

Slides:



Advertisements
Similar presentations
Adjustable Head Strap Instructions Step 1: To adjust the head strap hold goggle as above.
Advertisements

Training Support Package
Oxygen Administration R/C MERT Medic Assistant Lesson V.
Flange-lok Installation Instructions Quick Installation Guide rev. DB.
Strut Jack Operation The TeleCrib® Strut Jack is a removable 8,000 lb jack which fits over the strut body and gives the rescuer a controlled means for.
MINI BOX. STANDARD BOX MAGNUM BOX SPINDLE ASSEMBLY.
L.C. Technology ROBOT ASSEMBLY. Base Assembly BASE File off raised tabs on each side of Servo. Place Servo in vice between Fibre Clamps. Raised Tabs Repeat.
1 COLLEGE OF ENGINEERING Build An Electric Train.
How to thread the Sewing Machine. Winding the Bobbin Place your thread on the spool pin Pull thread around knob on opposite end of the machine Thread.
How to Make a Simple DC Motor
2 nd of Bachillerato IES Saavedra Fajardo PE teacher: Narciso Marín Marín.
Instructions for Printing Fluid Power Task Cards Print slides 2-5 and then take to a copy machine to make double sided copies Copy slide 2 to the front.
How to make a simple tempeh incubator. For all information regarding, how to make tempeh or purchasing of materials for tempeh/tofu making please visit.
HOSE ROLLS Straight roll ◦Lay the hose out straight and flat on a clean surface ◦Roll the male coupling over onto the hose to start the roll ◦Form a coil.
BASIC ANATOMICAL TERMINOLOGY
Featuring Bifurcation Trans-Radial Approach Technical Issues Martial Hamon Caen, France Provisionnal T stenting With the Frontier stent Main Branch Balloon.
The Camera -Using a 35mm SLR Camera - An Introduction to.
Shaft Replacement Standard Operating Procedure
Gauging Devices.
Annex 4 - Moving Frame and Whiffletree assembly
Harbor-UCLA Medical Center
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Tool Assembly Procedure
Endurant: A New Generation Endograft
Microscope Measurement
Ravi K. Ghanta, MD, John A. Kern, MD 
COMPASS SURVEYING.
Formative Assessment.
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones  Toshio Takayama, MD, PhD, Patrick J. Phelan,
Excel Basic Operation Manual
Rebecca C. Gosling et al. JIMG 2018;j.jcmg
Fanelli Laparoscopic Endobiliary Stent Suggested Instructions for Use
BUILDING A PC WEEK 1.2 You have 90 minutes to complete the 13 steps.
Step-by-step assembly instructions
Catheter-less angiography for endovascular aortic aneurysm repair: A new application of carbon dioxide as a contrast agent  Enrique Criado, MD, Loay Kabbani,
Edward G. Soltesz, MD, MPH, Roy K. Greenberg, MD 
Ravi K. Ghanta, MD, John A. Kern, MD 
BASIC PRINCIPLES OF AIRMANSHIP
Carlos F. Bechara, MD, Suman Annambhotla, MD, Peter H. Lin, MD 
Endovascular Treatment of Acute Descending Thoracic Aortic Dissections
MVB Assembly Instructions
Novel technique for endovascular salvage of a folded aortic endograft
Delphi Fuel pump. Overshoot protection screw. No load throttle adjust
Impact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysms  Michael L. Marin, MD, Richard E. Parsons,
1/17/2019.
Endovascular repair of thoracoabdominal aortic aneurysm using the off-the-shelf multibranched t-Branch stent graft  Bernardo C. Mendes, MD, Gustavo S.
Wire Stripping and Crimping
Initial experience with the Ventana fenestrated system for endovascular repair of juxtarenal and pararenal aortic aneurysms  Andrew Holden, MD, Renato.
Failure modes of thoracic endografts: Prevention and management
Physician modification of Gore C3 excluder endograft for treatment of abdominal aortic aneurysms anatomically unsuitable for conventional endovascular.
Thoracic endovascular aortic repair: The basics
Techniques in occluding the aorta during endovascular repair of ruptured abdominal aortic aneurysms  Mark Edward O’Donnell, DSEM, MRCS, Stephen A. Badger,
Results of a double-barrel technique with commercially available devices for hypogastric preservation during aortoilac endovascular abdominal aortic aneurysm.
Endovascular abdominal aortic aneurysm repair in patients with common iliac artery aneurysms – Initial experience with the Zenith bifurcated iliac side.
Technical aspects of repair of juxtarenal abdominal aortic aneurysms using the Zenith fenestrated endovascular stent graft  Gustavo S. Oderich, MD, Mateus.
Prediction of altered endograft path during endovascular abdominal aortic aneurysm repair with the Gore Excluder  David R. Whittaker, MD, Jeff Dwyer,
Topic: Measuring Distances on Maps
Family care home health agency, llc
The effect of endograft relining on sac expansion after endovascular aneurysm repair with the original-permeability Gore Excluder abdominal aortic aneurysm.
Volume 21, Issue 1, Pages e1-e3 (January 2011)
David J. Minion, MD, Christian C. Rodriguez, MD, Erin M
Endovascular abdominal aortic aneurysm repair in patients with common iliac artery aneurysms – Initial experience with the Zenith bifurcated iliac side.
Should patients with challenging anatomy be offered endovascular aneurysm repair?  Roy K Greenberg, MD, Daniel Clair, MD, Sunita Srivastava, MD, Guru Bhandari,
Θεματική ενότητα: Stenting
Ronald K. Binder et al. JCIN 2013;6:
EVAR Overview and stent-graft implantation in complex iliac anatomy
Twelve-year experience with intraluminal sutureless ringed graft replacement of the descending thoracic and thoracoabdominal aorta  Mehmet C. Oz, MD *,
Reverse slider technique using the Endurant stent graft for accurate proximal sealing in hostile neck endovascular aneurysm repair  Noriyasu Morikage,
Multicenter pivotal trial results of the Lifepath System for endovascular aortic aneurysm repair  Jeffrey P Carpenter, MD, William N Anderson, PhD, David.
Presentation transcript:

Deploying the Aorfix AUI Converter

Appearance of AUI Converter Converter has one length, 72mm overall. The ‘Aortic’ part is 40mm long The ‘Aortic’ part of the shortest Aorfix is 56mm long The Converter is designed to fit on the flow divider of the Aorfix The Converter has a ‘fish mouth’ which should have the same orientation as the primary graft.

RO Markers There are several RO markers on the devices to aid placement. The primary ones for placing the Converter are: The top of the cannulation socket of the primary graft has an RO ring around it. It marks the level of the flow divider. The top of the leg of the Converter also has an RO ring around it.

Deployment The Converter uses the same delivery system as the primary graft. It is inserted over a stiff wire, (Lunderquist is preferred) up the ipsilateral leg of the primary graft. The RO marker at the top of the socket of the primary graft should be identified and the RO marker at the top of the leg in the delivery system.

Deployment Contd. Align the RO marker at the top of the Converter’s leg with the RO marker at the top of the contralateral socket of the primary graft. Ensure that the fishmouth at the top of the Converter is aligned with the fishmouth at the top of the primary graft. Deploy the converter following the instructions to deploy the primary graft: Wind back the sheath control of the Converter delivery system (about 12 clicks) until it has come to the end of its travel (a stiffer click and the pins on the control project from the control) N.B. Do not operate the push rod control Pull back the sheath Release the push rod control (6 counter clockwise turns and pull back) Balloon the converter once in place

Top of Converter Bottom of Converter

The Only Watch Out If the primary graft has been compressed axially, the top of the Converter may lie slightly above the top of the graft. If this is suspect, the converter can be deployed slightly lower in the primary graft ie the RO marker on the leg of the converter can be placed 5mm to 7mm below the marker on the contralateral socket. The converter is 16mm shorter than the shortest body; this adjustment can place the Converter 21 to23mm below the top of the primary graft.

D4 - Proximal Diameter (mm) Part numbers For Aorflex the suggested sizes are 24-27-31 mm Part Number Product Description D4 - Proximal Diameter (mm) SG-HBC-25-A5-22 HELICAL CONVERTER 25 SG-HBC-27-A5-22 27 SG-HBC-29-A5-22 29 SG-HBC-31-A5-22 31