AIRCONDITIONER ERROR CODES

Slides:



Advertisements
Similar presentations
Wall Mounted J series Troubleshooting.
Advertisements

Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
INVERTER-Y TRAINING 2009.
Service Section Technical Training.
Engineer Training Machine Electrical Cabinet TJ8300 / TJ8500 Machine Electrical Cabinet (EC)
Page 1 Updated by: Yap Boon Thiam Technical Engineer Date: 09/5/2012.
Operating Functions.
Inspection & Preventive maintenance of breakers
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Enhanced Easy-Stop TM Trailer ABS Training. Enhanced Easy-Stop Trailer ABS System configurations to meet any air-braked trailer application 2S / 1M, 2S.
Daikin Altherma™ Troubling Shooting
1) The Meaning of the First Alphabet
2008 AQV, EH, DH and FJM Inverter Troubleshooting
TROUBLESHOOTING. 5WSS TROUBLESHOOTING ERROR CODEFAULTY INDICATION E1ROOM SENSOR CONTACT LOOSE E2INDOOR COIL SENSOR CONTACT LOOSE E3WATER OUTLET SENSOR.
Refrigerators.
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Digital Non-Programmable Thermostat. Digital screen Setpoint indicator- Appears when the Setpoint temperature is displayed Low battery warning Temperature.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
FAULT MESSAGES:- Action To Be Taken
Cleaning H50/52 Blowers The condition of the blower motor has a direct affect on the operation of an H50/52 fryer.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
1 March 2012 RAC Service tool RAC Service tool Service toolFunctionPart DC motor checker (DMCT) Operate the DC fan motor Noise test of DC motor.
Solid State University Understand the following components: Potentiometers Thermistors Capacitors Diodes Zener Diodes Transistors.
Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
2013 Microwave Service Training All models. Samsung HA Warranty ALL Warranties are subject to change, always verify. 1 Year Parts & Labor Base Warranty,
Product Introduction.
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Service/Review... Rule # 1: Use the KISS Principle!
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
2-Stage Heat Pump Defrost Options Defrost options: –30, 60, 90, 120 or Auto (Infinity/Evolution only) Defrost initiate temp: 32° F Defrost terminate temp:
1 Air Conditioning Pressure Switches. 2 High Pressure switch Used to protect the compressor When condensing temp gets too high Reads High Side Pressure.
2013 NATEF Task Area A-7 Heating, Ventilation, and A/C A. A/C System Diagnosis & Repair B. Refrigeration System Component D & R C. Heating, Ventilation.
Troubleshooting Electric Control Devices
Index Sr No. Description Slide no. 1
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
Air Conditioning Heating Refrigeration
Air Handler Terminology
Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self.
Air Handler Terminology
For Multiple refrigeration system
My Green House By Jayden White. Lighting The lights I am going to put in my house are compact fluorescent light bulbs. I will use these because:  They.
Keeps heat indoors in winter and outdoors in summer – means lower heating and cooling bills Rated by it’s R-value. The greater the R- value the better.
Thermal Physics III Cooling Processes Refrigerators, air conditioners, and heat pumps are devices that make heat flow from cold to hot. This is called.
6. Trouble Shooting Guide Breakthrough InnovationHVAC & Energy Solution 6.Trouble Shooting Guide ① You can find trouble shooting guide in General.
MCQUAY DIGITAL SCROLL SYSTEM
HVAC System Controls part 2 1 Heater controls Electrical: – Wiring diagrams – Blower controls Conventional circuits Multiplex circuits – Actuators Vacuum.
Problem Solving using Error Code Saijo Denki Inverter R-410A
DC Inverter Mini VRF Reference projects Reference Project Mini and Multi Improvements Product line -up.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
Refrigerant system of Inverter R-410A. denki.co.th Model type Model : Stand Model : Duct Model : Cassette Model : Wall mount Model : Wall and.
AIR CONDITIONING (COOLING)
Product: Air conditioner Training Manual Editor: Hao Guanghui
UTH-65A VER. CAUTIONS ! PLEASE USE THE OUTLET PREPARED BY A QUALIFIED SERVICEMAN AND MUST CONFIRM IT BEFORE APPLY[SING AN ELECTRIC CURRENT.
Service Section Technical Training. Sequential Controller SQ 1.0.
BASIC ELECTRICITY AND MAGNETISM
Model OutlineChassisBodyBody ElectricalEngine 1 Contents Click a Section Tab.
Refer to Service Manual for details Fault codes. To retrieve fault codes from the remote controller Press the ‘CHECK’ button for approximately.
2013 CHIGO Product CHIGO CMV VRF Control System.
E3 HVACR Controls and Devices
shift to the Test Mode (Forced Operation).
VRF Trouble Shooting 采用midea通用PPT模版, 参考《公司简介》PPT.
Fan Coil Controller FC/S 1.1
"This document can not be used without Samsung's authorization"
CHIGO VRF System Commissioning.
E3 HVACR Controls and Devices
TECHNICAL TRAINING 2007.
CONTROL BOX RMG
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Error codes for split systems
Presentation transcript:

AIRCONDITIONER ERROR CODES

SAC Galanz/VIL In-house Sr. No Problem Description Fault Message/Error Window -- AC 1 Room Temp Sensor Faulty/ cable cut E1 2 Coil Temp Sensor Faulty/ cable cut E2 SAC -- Midea Green Led blink along with operation LED 3 IDU Motor Faulty/ Cable cut/ feedback not received Only Green Led blink after 1 min SAC Galanz/VIL In-house F8 F6 F7 SAC --  GREE Blower Motor Error H6 Coil Sensor Error F2 Temp Sensor Error F1 4 Jumper Change (Check Connector 04) C5 SAC -- TCL E6

FOR CEILING MOUNTED AIR CONDITIONERS FLASHING OF RED LIGHTS PERFORMANCE FAULTS 1 TIME / 1SEC. FAULTY COILS 1 TIME / 3 SEC. COLD AIR PROTECTION (NORMAL FUNCTION) 2 TIMES / 4 SEC. ROOM TEMP. SENSOR FAULTS 3 TIMES / 5 SEC. 4 TIMES / 6 SEC. OUT DOOR UNIT (OVERFLOW, ELECTRIC NETWORK VOLTAGE FAULTS) 5 TIMES / 7 SEC. FROST RESISTANCE PROTECTION (NORMAL FUNCTION) 7 TIMES / 9 SEC. ABNORMITY OF OUT FEED BACK 8 TIMES / 10 SEC. OVERHEATING PROTECTION 9 TIMES / 11 SEC. WATER PUMP FAULTS

FOR CEILING MOUNTED AIR CONDITIONER (VA2400SPCA) OLD MODEL FLASHING OF RED LIGHTS PERFORMANCE FAULTS 2 TIMES / 4 SEC. FAULTY COILS 3 TIMES / 5 SEC. ROOM TEMP. FAULTS 4 TIMES / 6 SEC. WATER PUMP FAULTS 6 TIMES / 8 SEC. FROST RESISTANCE PROTECTION 7 TIMES / 9 SEC. OUTDOOR UNIT (OVERFLOW, ELECTRIC NETWORK VOLTAGE FAULTS) 8 TIMES / 10 SEC. OVER HEATING PROTECTION FOR FLOOR STANDING AIR CONDITIONERS FAILURE CODE CAUSE OF FAILURE E2 ROOM TEMP. FAILURE E3 PIPE TEMP. FAILURE E4 IMPROPER OPERATION OF OUTDOOR UNIT E8 FROSTING E7 EXTERNA FEEDBACK FAILURE OVERHEAT PROTECTION

Self Diagnosis for TCL make (VAS T) Models Self Diagnosis for Galanz make Wall Mounting Models VFD/LEV Display Error Code Malfunction Reason F6 or FF 06 Indication of the malfunction of PG motor F7 or FF 07 Indication of the malfunction of indoor temp sensor F8 or FF 08 Indication of the malfunction of indoor coil sensor F9 or FF 09 Indication of the malfunction of outdoor coil sensor Self Diagnosis for Galanz make Floor Standing Models F1 or FF 01 Indication of evaporator frost malfunction F3 or FF 03 Indication of outdoor coil overheated when cooling F4 or FF 04 Indication of indoor coil overheated when heating Indication of malfunction of indoor coil temp sensor Indication of malfunction of Outdoor coil temp sensor Self Diagnosis for TCL make (VAS T) Models Error Code Malfunction Reason E1 Room temp. sensor failure E2 Coil temp. sensor failure E3 Blower Motor Failure

ACTION TO BE TAKEN AFTER IDENTIFICATION OF ERROR

Action To Be Taken Fault Message Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor. E2 Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor. F8 F6 Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal. F1 Green Led blink along with operation LED Only Green Led blink after 1 min

Fault Message Action To Be Taken Clean & Place connector 04 properly. Check coil sensor wiring, Change coil sensor, Track/ SMD on PCB in series of coil sensor. F6 Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal. F7 Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor. H6 F2 F1 C5 Clean & Place connector 04 properly. E6 E2 E1

Clean & Place connector 04 properly. ODU FAULT MESSAGES Sr No Problem Red Light Yellow Light Green Light Action To Be Taken 1 Outdoor Evaporator Temperature Sensor Malfunction 5 Blink   Check sensor wiring, Connector of Sensor, Change outdoor sensor, Track/ SMD on PCB in series of sensor. 2 Outdoor Ambient Temperature Sensor Malfunction 6 Blink Check sensor wiring, Connector of Sensor, Change outdoor Ambient sensor, Track/ SMD on PCB in series of sensor. 3 Over current Protection Check Compressor Wiring for Short Ckt, Room Sensor/ Wiring/ Connector faulty. 4 IPM Protection 4 Blink If fault is permanent after 6 times, Check the PCB for Module Burnt/ Track Burnt/ Any damage. 5 Communication Malfunction Off Check the Communication cable between IDU & ODU for Cable Cut/ Loose connection/ Any other High Power cable adjacent to the AC cable. IDU FAULT MESSAGES Error Code Jumper Cap Malfunction C5 Clean & Place connector 04 properly. Indoor Sensor Malfunction FP Check room sensor wiring, Change room sensor, Track/ SMD on PCB in series of room sensor. Indoor Fan Failure H6 Check motor wires, Feedback wires, Motor Jam, Track burn/ SMD burn in series with feedback signal. H5

Connector 04 ( C5 Error In VPS )

WAC Control PCB SMD in series with Room sensor signal.

WAC Power PCB VDR 10K561 ( Over-Voltage protector ) Relays Can Damage Due To:- 1 Short Circuit in wiring 2 Wrong Wiring 3 Loose connections at Terminals ( Sparking ) VDR 10K561 ( Over-Voltage protector )

F6 Or H6 Error in SAC Motor Feedback connector ( 3 Pin) Includes Vcc, Feedback & Gnd. ( Check 5V between Vcc & Gnd ) Can Be Due to:- Motor Wires Cut Feedback wires cut Motor Jam ( Feedback signal not received) Track Burn on PCB ( Feedback not reach to MICON Faulty Connector of Feedback.

THANKYOU