Reduce Reuse Reclaim and Recycle Appropriate use of land Use water and energy efficiently Enhance human health Strengthen local economies Conserve plants.

Slides:



Advertisements
Similar presentations
Green Building for Comfort Dan Mackey, CR, CKBR, CGBP Daniel Mackey Construction Incorporated National Association of the Remodeling Industry.
Advertisements

Formulas.
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
How to lower the energy use of your home David Parker Building Analyst/ Energy Auditor Parker Energy Solutions David Parker Building Analyst/ Energy Auditor.
C HAPTER 4 C OMBUSTION A IR The importance of combustion, dilution, and ventilation air.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Heating, Ventilating, and Air-Conditioning
Performance measurement
“Do not take anyone’s advice as to how this building should be assembled.”
Heating, Ventilating, and Air-Conditioning (HVAC)
Radon in Your Home Presenter information here 4/2014.
1. EPA’s Healthy Schools initiative is working with schools and other partners to provide education about environmental health issues and how they impact.
Change in the way we build -Tighter -More chemicals -Air conditioning IAQ…Why is it a bigger issue than ever? Change in the way we live -90% of time indoors.
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
DOUGLAS FOX DIRECTOR, CENTER FOR SUSTAINABILITY AND GLOBAL CHANGE HANNAH KREITZER STUDENT UNITY COLLEGE, UNITY MAINE Living and Learning in TerraHaus.
Lesson 3 How does radon enter a home?. Slide 3-1 Predicted average indoor radon levels (U.S.) This map cannot be used to determine the radon level of.
Take in a Deep Breath! Blow It Out!!! Typical Annual Radiation Exposure mrem/yr.
Local Exhaust Fans. Biological Contaminates Moisture Combustion gases - If not burned properly can intro. CO. Gas cooktops Gas ovens Furnace Gas Hot.
The House as a System 1. Air Temperature and Water Vapor.
Lesson 10 How can you reduce radon in a home? Slide 10-1 Brief overview of radon mitigation Mitigation: reducing radon in air or water Requires trained,
Lesson 3 How does radon enter a home?. Slide 4-1 Predicted average indoor radon levels (U.S.) This map cannot be used to determine the radon level of.
Colorado State University Cooperative Extension Strong Family Healthy Homes Work Team.
Kitchen Ventilation.
RADON The Health Risks and Solutions. What is Radon? A naturally occurring radioactive gas. Colorless, odorless and tasteless. Found all over the U.S.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 5 Validating Combustion Air.
Colorado State University Cooperative Extension Strong Family Healthy Homes Work Team.
BECOMING GREEN Santa Margarita High School Academic Building.
1 Steps to Healthier Homes n Keep It: Dry Clean Pest-Free Ventilated SafeContaminant-Free Maintained.
Air Pollution TSWBAT: Define air pollution.
INDOOR AIR POLLUTION: RADON In 1990 EPA placed indoor air pollution at the top of the list of 18 sources of cancer risk Indoor pollution is rated by risk.
APES INDOOR AIR POLLUTION NOTES. INDOOR AIR POLLUTION The quality of indoor air can be two to five times (and even up to 100 times) more polluted.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Windows Do not open or close all windows and doors at the same time. Optimise the ventilation by experimenting with opening different windows instead.
Home Ventilation 1 Background: As Habitat homes are being built more tightly to reduce heat loss, there has been an increasing concern about the amount.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Source Strength Source Strength Removal Rate Removal Rate Ventilation and IAQ.
ASHRAE A Ventilation Standard for Residential Structures Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings.
© 2011 Pearson Education, Inc. This lecture will help you understand: Indoor air pollution and solutions.
VOC’s. Review of Signs and Symptoms People with allergies have hyperactive immune systems that think harmless things, such as pet dander, are dangerous.
Take in a Deep Breath! Blow It Out!!! Typical Annual Radiation Exposure mrem/yr.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Home Ventilation 1 Background: As Habitat homes are being built more tightly to reduce heat loss, there has been an increasing concern about the amount.
Types of heater: Gas Why Use Gas-fired Heating Equipment ä Most economical heating source ä Wide variety of equipment available ä Most common source.
Healthy Homes Overview
Indoor Air Pollution. I. Indoor Air Pollution A.In developing countries, the indoor burning of wood, charcoal, dung, crop residues, and coal in open fires.
Future City Research Ideas by Emily Levinson. Housing The homes include low-emissivity windows, attic insulation with heat resistance, exterior foam building.
Building a Greenhouse ©2001 AgriTeach.com (103001ms) Heating Source: Fact Sheet University of Maryland Co-op Extension Service, David S. Ross, Extension.
Radon in the home For most Americans, greatest exposure to radon is in home, especially in rooms that are Below grade (such as basements) In contact with.
Indoor Air Quality in Tribal Communities Institute for Tribal Environmental Professionals nau.edu/iaqtc 1.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
VENTILATION AND FENESTRATION
HEAT-GENERATING EQUIPMENT INTRODUCTION SELECTION EFFICIENCY FURNACES BOILERS CENTRAL HVAC SYSTEMS.
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Formaldehyde Emission Modeling in Manufactured Homes Jacqueline Bayer 1, Dr. Patrick Gurian 2, and Dr. Jin Wen 2 1 BS/MS Student, Dept. of Civil, Architectural,
VENTILATION AND AIR CONDITIONING Under the Subject Industrial Safety and Environment || ||
Indoor Air Quality The quality of the air in our homes and school may be worse than the air outside!
Volatile Organic Compounds (VOC)
Three topics The importance of measuring household energy usage over time Known knowns, known unknowns, and unknown unknowns What a house that’s part of.
RADON IN CANADA Your Name Here Your Title Here Your logo here
Electrical Gas Plumbing Heating & Cooling
Radon Environmental Issues for Real Estate Professionals
Radon Environmental Issues for Real Estate Professionals
RADON IN CANADA Tina Szewczyk RRT FCSRT CAE
Radon Environmental Issues for Real Estate Professionals
How can you reduce radon in a home?
Energy and Environment
Radon Environmental Issues
A Ventilation Standard for Residential Structures
Presentation transcript:

Reduce Reuse Reclaim and Recycle Appropriate use of land Use water and energy efficiently Enhance human health Strengthen local economies Conserve plants and animals Sustainable Strategies

Protect agricultural, cultural and archeological resources Build and maintain economically Nice to live in Build it Beautiful Sustainable Strategies

Healthy Indoor Air

Radon * Radon is estimated to cause about 21,000 lung cancer deaths per year, according to EPA's 2003 Assessment of Risks from Radon in Homes (EPA 402-R ). The numbers of deaths from other causes are taken from the Centers for Disease Control and Prevention's National Center for Injury Prevention and Control Report and 2002 National Safety Council Reports. EPA's 2003 Assessment of Risks from Radon in Homes (EPA 402-R )

Radon Zone 1 counties have a predicted average indoor radon screening level greater than 4 pCi/L (pico curies per liter) (red zones) Highest Potential Zone 2 counties have a predicted average indoor radon screening level between 2 and 4 pCi/L (orange zones) Moderate Potential Zone 3 counties have a predicted average indoor radon screening level less than 2 pCi/L (yellow zones) Low Potential

Radon

What is Radon? A radioactive gas that comes from the natural decay of uranium and is found in nearly all soils.

Radon Radon gets into the home through Cracks in concrete floors Construction joints Cracks in walls Gaps in suspended floors Gaps around service pipes Cavities inside walls The water supply (wells typically)

Radon Radon Resistant Construction Techniques Gas Permeable Layer This layer is placed beneath the slab or flooring system to allow the soil gas to move freely underneath the house. In many cases, the material used is a 4-inch layer of clean gravel. Plastic Sheeting Plastic sheeting is placed on top of the gas permeable layer and under the slab to help prevent the soil gas from entering the home. In crawlspaces, the sheeting is placed under the crawlspace floor. Sealing and Caulking All openings in the concrete foundation floor are sealed to reduce soil gas entry into the home. Vent Pipe A 3- or 4-inch gas-tight or PVC pipe (commonly used for plumbing) runs from the gas permeable layer through the house to the roof to safely vent radon and other soil gases above the house. Junction Box An electrical junction box is installed in case an electric venting fan is needed later.

Volatile Organic Compounds Volatile organic compounds (VOCs) are emitted as gases from certain solids or liquids. VOCs include a variety of chemicals, some of which may have short- and long-term adverse health effects.

VOCs Paints Lacquers Paint Strippers Cleaning Supplies Pesticides Building Materials Furnishings Glues Adhesives………

Health Effects Eye nose and throat irritation Headaches Loss of coordination Nausea Liver damage Kidney damage Central Nervous system damage Cancer

Formaldehyde What is Formaldehyde? Formaldehyde is a low cost and common chemical that has a strong pickle-like odor. It is currently used in thousands of products as an adhesive, bonding agent and solvent.

Formaldehyde Where is it found? Particle board, plywood, paneling, pressed- wood products Urea formaldehyde foam insulation Synthetic fabrics (especially permanent press) Produced through combustion Natural gas Wood Gasoline Tobacco

Formaldehyde Health Effects Vary Eye, nose and throat irritation Coughing, headaches, dizziness, and nausea The effects of long-term exposure are not well known The United States Environmental Protection Agency has listed formaldehyde as a chemical that can possibly cause cancer in people.

Formaldehyde What is an acceptable level in the home? 0.10 PPM or less If a higher level is measured steps should be taken to mitigate the problem

Formaldehyde Methods for lowering levels Remove the source Treat the source Ventilate Control the climate Allow products to off-gas

How are Radon and Formaldehyde Detected? Radon Detection Kits Formaldehyde

Bathroom Exhaust Fans CODE for Baths with bathing or spas facilities: Minimum 80 CFM Intermittent Ventilation required or Continuous Ventilation System at 20 cfm CODE for Toilet Rooms without bathing or spas facilities: 3SF Minimum Window ½ of which must be operable Minimum 50 CFM Intermittent Ventilation

Home Ventilation Institute Recommendations - Baths Bathrooms to 80SF - 80CFM fan (Code) Bathrooms 81sf to 100 sf – 1 cfm per square foot (~ 8 air changes/hour) Bathrooms over 100 sf add the CFM for each fixture Allow 50 CFM per standard toilets, shower and steam shower (put on timer) Allow 100 CFM per Whirlpool, garden and hot tubs HVI recommends continuous ventilations as augmentation to intermittent ventilation

Bathroom Exhaust Fans A toilet in its own enclosure should have its own fan Fans approved for wet areas should be placed over or very near the shower or tub when possible. Bath doors should be undercut at least 3/4 Leave fan on for 20 minutes after use of the bathroom

Ventilation Considerations Fan Type Propeller Fan – Limited air capacity and noisy Axial Fan – Better air movement but still noisy Centrifugal Blower (Squirrel Cage) The best

Humidistat ns Humidistat

Kitchens

Kitchen Exhaust Fans CODE (ASHRAE) The American Society of Heating, Refrigerating and Air-Conditioning Engineers 100 CFM Intermittent Or 25 CFM Continuous

Home Ventilation Institute Recommendations - Kitchens Wall Mount Hoods – 100 cfm per foot of width Island Mount Hoods – 150 cfm per foot of width

Air Flow Rules of Thumb R ule of Thumb 1: Take the hood area (in square feet) and multiply it by 75 to get the CFM (cubic feet per minute) for a wall hood, or multiply it by 100 for an island hood. Rule of Thumb 2: Allow 15 air changes per hour (ACH) for the kitchen. Take the kitchen volume (length x width x height) and divide by 4 to get the required CFM.

Rule of Thumb 3: Allow 1 CFM per 100 BTU's per hour (BTUH) heat output. Take the output of the oven and cooktop (if together or close) and divide by 100 to get the required CFM. Rule of Thumb 4: (this applies to commercial type ranges) Allow 100 CFM per linear foot of hood. Take the perimeter of the hood and multiply it by 100 to get the required CFM. Which rule of thumb is the best one to use? The most popular rules of thumb are #1 and #3. We typically use rule of thumb #1 when we size fans.

NKBA Recommendations

Ventilation Calculator

Why Ventilate? To provide enough air to keep occupants health To remove odors To dilute indoor pollutants To lower relative humidity

Negative Aspects Typical home Gas furnace – vents to outside Gas Hot Water Heater – vents to outside 2 bath fans – vent to outside 1 kitchen ventilator – vents to outside What happens when the home is winterized, windows closed, doors closed and all of these ventilators are running?

Furnace

Gas dryer

Gas Hot Water Heater

Hot Water Heater Vent

-Negative Pressure Where does the makeup air come from?

Hot Water Heater Vent

Negative Pressure What happens when we tighten the house up?

Heat Recovery Ventilator

HRV

ERV Energy Recovery Ventilator Energy Recovery Ventilator Used in the southern states where humidity is a problem Works the same as a HRV but ~ 9% of the stale air mixes with the fresh air to adjust humidity.

Bioclimate Chart

Example 1 Dry Bulb 73° Relative Humidity 50%

In the zone

Example 2 Dry Bulb Temp. 78° Relative Humidity 70%

Example 2 Dry Bulb Temp. 78° Relative Humidity 70% Requires a wind speed of 250 FPM (250*60)/5280 MPH = 2.84

Example 3 Dry Bulb Temp. = 50°F Relative Humidity 55%

Example 4 Dry Bulb Temp. = 64°F Relative Humidity 40%

What Does All This Mean?

Seasonal Enemies

British Thermal Units The basic measure of heat The amount of heat needed to raise one pound of water one degree Fahrenheit

Heat Content of Fuels 1 Kilowatt-hour electricity = 3,413 Btu 1 cubic foot of natural gas = 1,025 Btu 1 gallon fuel oil = 138,700 Btu 1 gallon kerosene = 135,000 Btu 1 ton of coal = 27,000,000 BTU 1 gallon LPG = 91,000 Btu 1 pound LPG = 21,500 Btu

Energy and Power Power is the INSTANTANEOUS use of energy Think of it as POTENTIAL use, whether it is running or not (engine, light bulb) Btu/h Watts, Kilowatts (Watts = Volts x Amps) the amount of voltage across a circuit x the current through the circuit Energy is USE of power over TIME (heat energy) Btu/h x hours = Btu Watts x hours = Watt hour (Kilowatt x h = kWh)

FUELS Natural Gas - Piped in under pressure Liquid Propane (LP) Stored in home tank Fuel Oil Electricity Coal Wood

Forced Air Furnaces Gas AFUE - annual fuel-utilization-efficiency rating measured as a percentage The higher the percentage, the more heat the furnace can ring from each therm of gasand the lower the environmental impact of its emissions. The lowest allowed is 78% The most efficient models have an AFUE of about 97 percentor near-total efficiency.

Energy Star Qualified Minimum AFUE of 85% to 90%

HEPA Filter

Standard Efficiency Furnace Steady State Efficiency or Combustion Efficiency ~80% Annual Fuel Utilization Efficiently (~65%)

Standard Efficiency Furnace Incomplete Combustion 0.5 On-Cycle Stack Loss 20% to 25% Pilot Light Loss 6% Off Cycle Loss 0-10% Jacket Loss 0-0.2% Cycling Losses 0-10% Duct Losses 0-40% Actual Heating System Delivered? 40%-65%

High Efficiency Furnace Steady State Efficiency or Combustion Efficiency ~90% Annual Fuel Efficiency (AFUE Rate) ~90%

High Efficiency Furnace Incomplete Combustion 0.5 On-Cycle Stack Loss <10% Pilot Light Loss 0% Off Cycle Loss 0% Jacket Loss 0-0.2% Cycling Losses 0-10% Duct Losses 0-40% Actual Heating System Delivered? 70%-90%

Two Measures of Efficiency in Heat Pumps HSPF – Heating SEER - Cooling

Heating Seasonal Performance Factor (HSPF) BTUs produced/watt-hours Heat Pumps manufactured after 2005 must have a HSPF of at least 7.7 The Most efficient have a HSFP of 10

Seasonal Energy Efficiency Ratio (SEER) Power output/Power input The higher the number the more efficient All Air Conditioning units sold after January 2006 must have a SEER rating of at least 13. Energy Star central air conditioning must have a SEER rating of 14 Window air conditioners are exempt from this rating Updating from a 9 SEER rated system to a 13 can save 30% on your energy consumption

Pros and Cons of Heat Pumps Electrically Powered Can be used in conjunction with a forced air furnace Not well suited in extremely cold climate Noise

Radiant Floor Heat Three types Radiant Air Floors Electric Radiant Floors Hot Water (Hydronic)

Radiant Floor Heat Types of installation Wet Installations Large thermal mass of a concrete slab floor lightweight concrete over a wooden subfloor Dry Installations Where the installer "sandwiches" the radiant floor tubing between two layers of plywood or attaches the tubing under the finished floor or subfloor.

Radiant Floor Heat Air Heated Radiant Floors Not recommended for residential applications Electric Radiant Floors -

Electric Radiant Heat - Wet Installation

Wet Installation

Dry Installation

Hydronic Radiant Heat

Wet Installation PEX piping in Concrete (thick slab)

Wet Installation Thin Slab Application Gypcrete over plywd

Heat Pump and Air Handler Heat Pump Air Handler Air Cleaner Thermostat

Heat Pump and Furnace Indoor Cooling Coil Heat Pump Furnace Air Cleaner Thermostat

Cooling

Air Conditioner and Furnace Air Conditioner Furnace Indoor Cooling Coil Thermostat Air Cleaner

Air Conditioners and Air Handlers Thermostat Air Conditioner Air Handler Air Cleaner

Cooling

Whole House Ventilation

Natural Ventilation

Ceiling Fans Sizing Ceiling Fans Largest dimension of room Minimum Fan Diameter 12 feet or less36-inches feet48-inches 16 – 17.5 feet52-inches feet56-inches 18.5 feet2 fans

com

Heating Degree Days Heating Degree Days are a measure of how cold your climate is. If the average outside temperature for a day is 1 degree less than the inside temperature (68°), then you would accumulate 1 degree day on that day. nline/ccd/nrmhdd.txt nline/ccd/nrmhdd.txt

Portland Month startingHDD% Estimated 11/1/ /1/ /1/ /1/ /1/ /1/ /1/ /1/ /1/ /1/ /1/ /1/

UA Calculation R = (A * Δ T) / (3.413 * W) W = Watts = Constant (BTU/Watt) ΔT = Change in temp A = Area in Square Feet

R = (A * Δ T) / (3.413 * W) Outside Temperature = 35° Heat source = 100 Watts Total Area = 520 SF Temperature inside = 55° Calculate the R Value for the given area R30

R = (A * Δ T) / (3.413 * W) Outside Temperature = 20° Insulation = R30 Total Area = 3520 SF Home 30x40x8 Temperature inside = 68° Calculate wattage of the heat source for the given area Watts