Designing a Precision Mechanical System:. Referring to local new construction, remodeling projects (including historic renovations), this course will.

Slides:



Advertisements
Similar presentations
Arizona Priority Lists Charlie Gohman Az Dept of Commerce Energy Office.
Advertisements

BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
Energy Audit Kaylin Fitzgerald Environmental Science Mr. Fitzgerald.
Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2J: Building.
Energy Efficient Heating Ventilating and Air Conditioning.
Passive house. Definition A Passive house is a buildings with good comfort conditions during winter and summer, without traditional space heating systems.
Energy Efficiency: Benefits to Apartment Owners & Tenants
Wiencek + Associates Architects + Planners Historic Dupont Circle Wiencek + Associates Architects + Planners, DC LLP 1814 N St., NW Washington, DC
Energy Conservation. 1. Air Sealing Holes/Cracks 2. Improved Insulation 3. Increased Efficiency of Heating/Cooling & Domestic Hot Water (DHW) 4. Lighting.
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
How to lower the energy use of your home David Parker Building Analyst/ Energy Auditor Parker Energy Solutions David Parker Building Analyst/ Energy Auditor.
Heating, Ventilating, and Air-Conditioning
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
“Do not take anyone’s advice as to how this building should be assembled.”
Heating, Ventilating, and Air-Conditioning (HVAC)
Department of Energy Energy Savers PowerPoint: Heating and Cooling 4 of 12.
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
The House as a System 1. Systems in a Home Electrical Plumbing Comfort Control (HVAC) Structural Moisture Control Air Infiltration Thermal Insulation.
The Three Tiered Philosophy
Energy Efficient Heating and Cooling Systems For Today Geothermal Heating, Cooing And Hot Water Systems.
A Home Energy Workshop. Developed by Central Vermont Community Action Council In partnership with Efficiency Vermont.
Welcome! Earth Day Webinar April 22, Agenda ENERGY STAR qualified homes Amber Stewart – ENERGY STAR Account Manager Meritage Green C.R. Herro –
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Moisture Barriers WEATHERIZATION INSTALLER/TECHNICIAN FUNDAMENTALS.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
The House as a System 1. Air Temperature and Water Vapor.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
The Energy Star Home Drew Tepper. Overview What is an energy star home? What is an energy star home? New Homes New Homes Existing Homes Existing Homes.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Moisture Assessment WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
Your House as a Healthy System Bruce Stahlberg. Improvements / Remodeling When one has finished building one's house, one suddenly realizes that in the.
Overview of Energy Efficiency & Renewable Energy (Draft version) Prepared by Natural Resources Canada in association with Indian and Northern Affairs Canada.
Massachusetts New Homes with ENERGY STAR ® The sponsors of the Massachusetts New Homes with ENERGY STAR are Bay State Gas, Berkshire Gas, Cape Light Compact,
Comfortable homes that save the world Sustainable Environmental Economic Development October 27, 2007 Don Otto dpoconstruction.com Don Otto dpoconstruction.com.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
New Mexico State University EFFICIENT RESIDENTIAL ENERYGY Fahzy Cooperative Extension Service ______ County.
Rio Grande Valley Sustainability Council 7 th Annual Energy Efficiency and Conservation Conference July 18, 2013.
Conservation and Environmental Design and Construction
Energy efficiency in buildings Monga Mehlwana Tuesday, 05 October 2010.
Trade Skills Print Reading and Ductwork. 2 Drawings are a useful tool in manufacturing and construction because most people find it difficult to.
Energy Conservation February 8, Steve Wilson, MBA, CEM, CDSM, BEP The Energy Guy.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 Energy Efficient Housing. 2 Why construct energy efficient structures? Bottom Line !!! Money It may save up to 60% of the cost to heat/cool the structure.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
Healthy Homes Home Energy & Weatherization. Energy Management for Home goals … save energy provide comfort assure safety and health.
Energy stars ► 1. Effective Insulation ► Properly installed and inspected insulation in floors, walls, and attics ensures even temperatures throughout.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
VENTILATION AND FENESTRATION
 Welcome & introduction  Health & safety  Mobile ‘phones  Agenda.
When drawing your plan, try and add as much detail as you can, labelling different features, such as double glazed windows and cavity walls. Draw two.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 1 Part 1 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
ENERGY SYSTEMS LABORATORY ABOVE CODE ENERGY ENHANCEMENT PROJECT for The City of Arlington ENERGY SYSTEMS LABORATORY Texas Engineering Experiment Station.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Moisture Assessment WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
SMART ENERGY EFFICIENCY FOR SMART PEOPLE PHOTO CREDIT: S. STEWART DOE Solar Decathlon nd Place University of Illinois at Urbana- Champaign.
Announcement: The Course Test is Net week ! On Wednesday, October 12 It starts at 1 pm sharp.
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
The Principles of Green Remodeling
Building Environmental Systems
Appalachian State University
Energy Innovations in Residential Buildings
The American Association
What We Do Orientation to my perspective-
Presentation transcript:

Designing a Precision Mechanical System:

Referring to local new construction, remodeling projects (including historic renovations), this course will explain the impact of designing a precision mechanical system and the various energy solutions available to make the home as energy efficient as possible. The coastal environment presents many building envelope problems. Today we will identify the most common failures in the envelope and discuss how to avoid them in the design phase.

BUILDING ENERGY CODES Todays energy, economic, and environmental challengescombined with the fact that buildings consume nearly 40% of the nations energymake energy codes a central part of a sustainable future. Todays energy, economic, and environmental challengescombined with the fact that buildings consume nearly 40% of the nations energymake energy codes a central part of a sustainable future.

Top Ten Reasons for Building Energy Codes 10. PROVIDE a common foundation for evaluating, regulating, and incentivizing building design, construction, technologies, and performance. 9. SUPPORT energy conservation and efficiency actions beyond minimum code levels. 8. HELP drive the development and deployment of new building technologies and design strategies. 7. PROVIDE a cost-effective step toward mitigating problems associated with growing demand for energy and power resources. 6. INCREASE the use of energy efficient technologies proven through incentive programs, freeing up resources to focus on new, more efficient additional technologies.

Energy Codes Continued. 5. PROVIDE a common basis upon which to educate the building design and construction community in energy efficiency. 4. SAFEGUARD owners and tenants from long term financial burdens that can result from short-term design and construction decisions. 3. CONTINUE to progress in terms of stringency, scope, and enforcement emphasisall of which provide new jobs or opportunities to enhance the skills of the current workforce. 2. HELP protect the natural environment from unnecessary emissions. 1. ENERGY CODES not only save money, but also help to reduce needless consumption of energy to heat, cool, light, ventilate and provide hot water for newly built residential and commercial buildings constructed without adequate energy efficiency features.

IDENTIFYING THE PROBLEMS! Energy Evaluations Energy Audits IAQ Tests Manual J Heat Load Calculations

Energy Evaluations HVAC HVAC Hot Water Hot Water Windows Windows Glazing Glazing Ductwork and location of ductwork Ductwork and location of ductwork Fireplaces Fireplaces Attics and Crawlspaces Attics and Crawlspaces Visual inspection of entire envelope Visual inspection of entire envelope An Energy Evaluation is an initial inspection of a homes largest energy consumers.

Energy Audits An Energy Audit An Energy Audit can help you assess how much energy your home uses and evaluate what measures you can take to improve efficiency. Thorough audits often use equipment such as blower door tests, which measure the extent of home infiltration in the building envelope, and infrared cameras, which reveal hard to detect areas of air infiltrations and missing insulation.

IAQ Tests Indoor Air Quality Tests: Used after the Energy valuation if the presence of old is found in the home. A sample of the existing mold issues would be gathered and sent to a third party laboratory for evaluation.

Manual J and D Heat Load Calculations: The Correct Way to Size a System Key factors for correctly sizing a heating And cooling system include the following: Local Climate Local Climate Size, Shape, and Orientation of the house Size, Shape, and Orientation of the house Insulation Levels Insulation Levels Window area, location, and type Window area, location, and type Air infiltration rates Air infiltration rates The number and ages of occupants The number and ages of occupants Occupant comfort preferences Occupant comfort preferences The types and efficiencies of lights and major home appliances (which give off heat). The types and efficiencies of lights and major home appliances (which give off heat).

Solutions! Properly sized Energy Efficient HVAC system Proper location of ductwork Tankless Hot Water Heaters Insulation Enclosed Crawl Space Dehumidification Energy Efficient Windows, Sliding Glass Doors and French Doors

Proper Size! Age of Unit! Energy Efficient HVAC Systems Proper Size! Age of Unit! The most common sizing mistake is in over-sizing. This not only makes the new system more expensive to install, but also forces it to operate inefficiently, break down more often, and cost more to operate. Oversized heating equipment also often creates uncomfortable and large temperature swings in the house. Oversized air conditioners do not run long enough to dehumidify the air, which results in the clammy feeling and unhealthy mold growth in many air-conditioned houses.

Tankless Hot Water Heaters Heating water accounts for up to 30 percent of the average home's energy budget. Gas- fired tankless water heaters can cut your energy costs up to half over regular storage heaters.

INSULATION Open Cell Foam Low-density, spray-applied polyurethane foam. Porous, not a vapor barrier, no added structural stability, R Value 3.8 per 1 inch. Open Cell Foam

Closed Cell Foam Closed Cell Foam INSULATION Closed Cell Foam Closed Cell Foam Polyurethane insulation that delivers high R- value plus Air Barrier, moisture vapor retarder, and water barrier that blocks air infiltration and air-borne pollutants while controlling moisture movement to provide increased comfort with lower energy usage.

Enclosed Crawl Space Dehumidification Around the year 2015, energy code will state that all duct work is to be in conditioned space. In our Warm and humid climate zone, moldy duct work is A common issue. Crawl spaces where duct work exists that are not dehumidified are a breeding ground for mold and other indoor air quality issues. This can lead to Structural issues, swelling and cupping of Hardwood floors, and certain health issues.

Energy Efficient Windows, Sliding Glass Doors and French Doors Keep fenestration below 20% window to wall area R-3 Window vs R-13 wall Solar Heat Gain Windows get covered up anyway!

U-factor--The rate at which a window, door, or skylight conducts non-solar heat flow. The lower the U-factor, the more energy-efficient the window, door, or skylight. Solar heat gain coefficient (SHGC)--A fraction of solar radiation admitted through a window, door, or skylighteither transmitted directly and/or absorbed, and subsequently released as heat inside a home. The lower the SHGC, the less solar heat it transmits and the greater its shading ability. Air leakage--The rate of air infiltration around a window, door, or skylight in the presence of a specific pressure difference across it. A product with a low air leakage rating is tighter than one with a high air leakage rating. Heat Gain and Loss Windows, doors, skylights can gain and lose heat in the following ways:

New Construction Scope of WorkNew Construction Process Met with Architect and Homeowner to go over copy of finalized plans and building materials in order to begin designing the homes mechanical system. Met with Architect and Homeowner to go over copy of finalized plans and building materials in order to begin designing the homes mechanical system. New home specifications were entered into Manual J Heat Load Calculation. New home specifications were entered into Manual J Heat Load Calculation. The thermal envelope is the most important concern for the manual j and then the major appliances and energy consumers in the home. The thermal envelope is the most important concern for the manual j and then the major appliances and energy consumers in the home.

This was a brick home built on a slab. No soffet or ridge vents were installed in this construction. The home was spray foamed from the floor at the slab all the way to the roof with a mixture of open and closed cell foam. COMPLETE ENCAPSULATION! Due to the size of the home, 3200 SQ. FT. one level home, we chose 2- 2 stage split heat pumps with variable speed air handlers. This allows for more capacity when needed during hotter months, and less capacity, using less energy when the heat load is not as demanding. The 2 stage with variable speed is controlled by a thermostat that doubles as a humidistat to allow for better dehumidification. Windows were double pane low E. Tankless hot water heater installed sized to consumers usage and need. Because of complete spray foam encapsulation, all duct work was in conditioned space.

Remodel or Retro-fit Home energy evaluation performed SQ FT Ranch home built in 1954 on a slab. Old windows and doors. Un-insulated Gas Tank Style Hot Water Heater approximately 15 years old. Duct work was leaky and the insulation on the duct work was breaking down. It was located in a unconditioned, unvented attic. HVAC system was approximately 15 years old. Blown insulation in attic approximately R15.