Empirical Modeling of a Rolling-Piston Compressor Heat Pump for Predictive Control in Low-Lift Cooling Nicholas Gayeski, KGS Buildings, LLC Tea Zakula,

Slides:



Advertisements
Similar presentations
Benefits of Air Source Heat Pumps Larry Butz GEA Consulting.
Advertisements

ACTIVE LEARNING PROCESS
Chapter 11 Refrigeration Cycles Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 5th edition by Yunus A. Çengel.
CHEMICAL ENGINEER University of Valladolid
Refrigeration Cycles د/ محمود عبدالوهاب.
Chapter 3. HVAC Delivery Systems
Refrigeration Cycles CHAPTER 11: PTT 201/4 THERMODYNAMICS
OFF DESIGN PERFORMANCE PREDICTION OF STEAM TURBINES
UCSD Medical Center - Hillcrest Campus Case Study Gerry White Facilities Design & Construction University of California, San Diego.
O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Status of Web Versions of the DOE/ORNL Heat Pump Design Model C. Keith Rice Oak Ridge.
Lindbergh Field International Airport New Terminal Bill Mahoney LSW Engineers.
INTRODUCTION. Seminar on IMPROVEMENT OF THERMAL EFFICIENCY BY RECOVERY OF HEAT FROM IC ENGINE EXHAUST.
REFRIGERATION Refrigeration may be defined as the process of removing heat from a substance under controlled conditions and reducing and maintaining the.
1 Optimal Control of Chiller Condenser Sub-cooling, Compressor Speed, Tower Fan and Pump Speeds, and IGV Omer Qureshi, Hassan Javed & Peter Armstrong,
Efficient Low-Lift Cooling with Radiant Distribution, Thermal Storage and Variable-Speed Chiller Controls Srinivas Katipamula, Ph.D. Peter Armstrong, Ph.D.,
Entropy balance for Open Systems
HVAC System Design PES Institute of Technology. Objective Goal: To develop an automotive air-conditioning system that is smaller and lighter than with.
Model predictive control for energy efficient cooling and dehumidification Tea Zakula Leslie Norford Peter Armstrong.
Refrigeration Cycles Chapter 11.
PREDICTIVE PRE-COOLING CONTROL FOR LOW LIFT RADIANT COOLING USING BUILDING THERMAL MASS.
Vapor and Combined Power Cycles
Control System Instrumentation
Lecture Objectives: Model processes in AHU –Use eQUEST predefined models –Use detail modeling Define your topics for your final project.
44 th Annual Conference & Technical Exhibition By Thomas Hartman, P.E. The Hartman Company Georgetown, Texas Sustainable Chilled Water.
Lecture Objectives: Finish heat pump example Review Psychrometrics
Pacific School Of Engineering. Guided By:- Asst.Prof.Vatsal patel Submitted by:-  Kotadiya Reshma :  Ladva Piyush : 
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Lecture Objectives: Final discussion about HW3 Introduce more final project topics Continue with HVAC Systems.
DATA-DRIVEN MODEL PREDICTIVE CONTROL OF LOW-LIFT CHILLERS PRE-COOLING THERMO-ACTIVE BUILDING SYSTEMS Nick Gayeski, PhD Building Technology, MIT IBPSA Model.
Spring 2006  Harvard Science, A 52 FHA+MBM Lecture 18, 1 Science A 52 Lecture 18; April 17, 2006 Refrigeration a)Technical background b)Visit to the Chilled.
Equation solvers Matlab Free versions / open source codes: –Scilab MathCad: Mathematica:
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee November 16, 2011 Mira Vowles, P.E., CEM.
Important variables Water: Air: Conversion:
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Variable-Speed Heat Pump Model for a Wide Range of Cooling Conditions and Loads Tea Zakula Nick Gayeski Leon Glicksman Peter Armstrong.
Refrigeration Basics 101.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Vapour Compression Refrigeration Systems
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
Lecture Objectives: Finish with software intro HVAC Systems
Alex Gee Jon Locke Joe Cooper Kylie Rhoades Clara Echavarria Ice Energy Extraction.
REFRIGERATION SYSTEMS
Energy and the Environment Fall 2013 Instructor: Xiaodong Chu : Office Tel.:
Chapter 11 Refrigeration Cycles Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 8th edition by Yunus A. Çengel.
Announcement Course Exam November 3rd In class: 90 minutes long Examples will be posted on the course website.
SMART PCA.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Lecture Objectives: Cooling towers and modeling Project 1 Thermal storage systems.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Unit efficiency versus Building System efficiency – Equipment Ratings EER and COP.
Lecture Objectives: Discuss the exam problems Answer question about HW 3 and Final Project Assignments Building-System-Plant connection –HVAC Systems.
Lecture Objectives: Differences in Conduction Calculation in Various Energy Simulation Programs Modeling of HVAC Systems.
Objectives Learn about Fans Discuss: Exam (I will have an extra office hour on Monday at 8:00 am) Final Project (I need your group member lists till tomorrow).
Final Project Format and Deliverables Examples
Final Project I need your proposal about the final project! It should include –Title –Group members –Objective –Short description –Methodology –Expected.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Lecture Objectives: Review Psychrometrics Introduce Air Handling Unit
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Lecture Objectives: Learn about thermal storage systems
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Lecture Objectives: Continue with Sorption Cooling
Thermal Energy Storage
Lecture Objectives: Answer questions related to HW 4
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Lecture Objectives: Answer questions related to HW 4
Energy Efficiency in District Coiling System
Control System Instrumentation
Lecture Objectives: Review Psychrometrics Introduce Air Handling Unit
Lecture Objectives: Discuss HW4 parts
Presentation transcript:

Empirical Modeling of a Rolling-Piston Compressor Heat Pump for Predictive Control in Low-Lift Cooling Nicholas Gayeski, KGS Buildings, LLC Tea Zakula, Massachusetts Institute of Technology Prof. Peter R. Armstrong, Masdar Institute of Science and TechnologyProf. Leslie K. Norford, Massachusetts Institute of Science and Technology Low-lift cooling systems Low-lift cooling is a low-energy cooling strategy that employs model-predictive control of a low-lift chiller to pre-cool thermal energy storage, enabling more frequent low pressure ratio chiller operation. The diagram below illustrates the primary components of the model- predictive control required for low-lift cooling. Building data and forecasts are incorporated into an optimization algorithm that uses a performance model of a low-lift chiller and a data- driven building temperature response model to predict an optimal chiller control schedule. The chiller pre-cools thermal energy storage, such as a thermo-active building system, and delivers radiant cooling to meet sensible cooling loads while a dedicated outdoor air system (DOAS) meets latent loads. Heat pump performance testingConclusion Low-lift cooling is a low-energy cooling strategy that requires a model of chiller performance to implement model-predictive control. By measuring the performance of a heat pump condensing unit over a broad range of conditions spanning pressure ratios from 1.2 to 4.8, empirical curve-fit models of condensing unit performance were identified suitable for integration in a low-lift cooling model-predictive control algorithm. These curve-fit models are simple four-variable cubic polynomials as a function of outdoor air temperature, zone air temperature, compressor speed, and condenser fan speed. The zone air temperature, or evaporator fluid inlet temperature, can be replaced with chilled water return temperature when representing the performance of a chiller T - Temperature (°C) S - Entropy (kJ/kg-K) psia Radiant cooling and variable speed pump Predictive pre-cooling of thermal storage (night-shifting) and variable speed fans Low-lift refers to a lower temperature difference between evaporation and condensation. A low lift vapor compression cycle requires less work Variable speed compressor and load spreading Conventional cycle Low lift cycle 2020 Table 2. Heat Pump Experimental Test Stand Sensor Descriptions LabelSensor descriptionSensor typeAccuracy T rs Suction refrigerant temperature (insulated pipe surface temperature measurement) T-type thermocouple0.4% T rd Discharge refrigerant temperature (insulated pipe surface temperature measurement) T-type thermocouple0.4% T rxvi Expansion valve inlet refrigerant temperature (insulated pipe surface temperature measurement) T-type thermocouple0.4% T rxvo Expansion valve outlet refrigerant temperature (insulated pipe surface temperature measurement) T-type thermocouple0.4% T az Evaporator zone air temperatureT-type thermocouple0.4% T aei Evaporator inlet air temperatureT-type thermocouple0.4% T ao Ambient outside air temperatureT-type thermocouple0.4% T ae Evaporator air temperature difference9-junction thermopile with T- type thermocouples 0.4% T aci Condenser inlet air temperatureT-type thermocouple0.4% T aco Condenser outlet air temperatureT-type thermocouple0.4% T ac Condenser air temperature difference9-junction thermopile with T- type thermocouples 0.4% P rs Suction refrigerant pressurePiezoresistive pressure transducer 1% P rd Discharge refrigerant pressurePiezoresistive pressure transducer 1% P rxvo Expansion valve outletPiezoresistive pressure transducer 1% P ao Ambient air pressure measured at local weather stationMeasured at weather station KMACAMBR9 ac Volumetric condenser air flowrateMeasured with anemometer traverse following ASHRAE Fundamentals (2005) WzWz Total power to the zone control volume, including fan and heaters Three phase analog power meter with separate current transducers 0.5% W unit Total power to the heat pump outdoor unit, including inverters, fan and compressor Three phase analog power meter with separate current transducers 0.5% W dc,fi DC power to the condenser fan inverterDigital power meter0.1% W dc,ci DC power to the compressor inverterDigital power meter0.1% W 3,f Three phase power from the inverter to the condenser fan Digital power meter0.1% W 3,c Three power from the inverter to the compressorDigital power meter0.1% Table 1. Conditions for Steady-state Testing VariableTest conditions (131 combinations of the following) Condenser air inlet temperature15, 22.5, 30, 37.5, 45 °C (59, 72.5, 86, 99.5, 113 °F) Evaporator air inlet temperature14, 24, 34 °C (57.2, 75.2, 93.2 °F) Compressor speed19, 30, 60, 95 Hz Condenser fan speed300, 450, 600, 750, 900, 1050, 1200 RPM Predict 24-hour optimal chiller control schedule using chiller and building models Variable capacity chiller operation Load forecasts Building data Identify building temperature response models Active charging discrete TES Direct zone cooling Pre-cooling thermo-active building system Passive pre-cooling intrinsic TES Occupied zone DOAS dehumidification Low-lift chiller/heat pump In order to accomplish model-predictive control for low-lift cooling, a detailed chiller model is needed that captures chiller performance at low pressure ratios. Frequent low pressure ratio, or low-lift, operation is a key feature of low-lift cooling that reduces energy consumption. The temperature-entropy diagram for refrigerant R410A below shows how low-lift cooling systems shrink the work polygon for the vapor compression cycle, resulting in a similar cooling effect but reduced work. A low-lift cooling system achieves more frequent low-lift operation by: shifting loads to the night time and allows for more part load operation by pre-cooling thermal energy storage, allowing for moderate chilled water temperatures by using radiant cooling and meeting latent loads with efficient DOAS dehumidification, and utilizing high turn down ratio variable capacity chillers which operate efficiently at low part load. Zone control volumeElectronic expansion valve EvaporatorCondenser Compressor Validation of measurements A heat balance and a mass balance on the calorimeter test data was performed to validate measurements of chiller performance. The heat balance was calculated from direct measurements of evaporator cooling load, condenser heat rate, and three phase compressor power consumption using the following equations: Condenser heat rate: Evaporator heat rate: Compressor power: Energy balance: Each of the variables used above were measured directly from sensor measurements described in Table 2 except for condenser air density ρ, specific heat c p, and the zone control volume thermal conductance UA z. The pressure and temperature dependent density and specific heat of the condenser air were calculated from air temperature and pressure measurements. The thermal conductance UA z across the zone control volume was determined from measurements of steady- state temperature difference across the control volume observed with constant heat inputs to the control volume and constant outdoor temperature. The normalized root mean square error (RMSE) of the heat balance is shown in the figure below. The refrigerant mass balance was performed by comparing the estimated mass flow rates across the compressor, condenser and evaporator. This relative comparison was performed in lieu of installing a refrigerant mass flow meter in the test stand to make an absolute comparison. Mass flow rates were calculated from the following equations.. Compressor mass flow rate: Condenser mass flow rate: Evaporator mass flow rate: The normatlized RMSE of the mass balance, where the average of all three measurements is used as a baseline, shows the relative accuracy of the mass flow rate estimates in the figure below. Both the energy and mass balances at steady state test conditions show reasonable normalized root mean square errors, 4.3 percent and 5.1 percent respectively. Empirical heat pump model A simple curve-fit empirical model of the heat pump condensing unit performance is necessary to integrate into a low-lift predictive control volume. Curve-fit models are commonly used to represent temperature and load dependent chiller performance. The curve-fit model presented here is valid for a rolling-piston compressor heat pump spanning pressure ratios of 1.2 to 4.8 and operating conditions consistent with those in Table 1. A four-variable cubic polynomial model of cooling rate, power consumption, and electric input ratio (EIR) (also the reciprocal of the coefficient of performance (COP)) was found to accurately represent the measured chiller performance data. Three 4-variable cubic polynomials can be identified where the dependent variable (DV) iseither cooling rate, power, or EIR. The coefficients C i have been identified by regression from measured data. The variable f is condenser fan speed and ω c is the compressor speed. The accuracy of these three curve-fit models are shown in Figure 7, where the measured value of EIR, power, or cooling rate is plotted against the predicted value for each test condition according to the empirical performance curves. A heat pump calorimeter test stand was constructed and used to generate a detailed curve-fit performance model of an outdoor unit heat pump comprising a compressor, condenser, condenser fan and electronic expansion valve valid at low pressure ratios. The heat pump test stand is shown in the image on the right. Tests at 131 steady-state conditions were performed at constant compressor speed, condenser fan speed, condenser air inlet temperature, and evaporating temperature at combinations of conditions listed in Table 1. The power consumption and cooling capacity of the outdoor unit were measured at each condition, along with all of the variables listed in Table 2. Critical variables, such as discharge temperature and pressure, were allowed to achieve steady state before data was collected. Figure 1. Conceptual diagram of a low-lift cooling system Figure 2. Reduced work polygon for a low-lift vapor compression cycle Figure 4. Heat pump calorimeter test stand schematic Figure 3. Heat pump calorimeter test stand (at right) Figure 5. Compressor, condenser and evaporator energy balance measurement validation Figure 6. Refrigerant mass flow rate measurement validation Figure 7. Accuracy of the empirical chiller models for representing electric input ratio (left) power consumption (center), and cooling capacity (right) Heat pump performance curves These simple curve-fit empirical models of the heat pump condensing unit performance can be integrated into a model-predictive control optimization in which the chiller power consumption is minimized. Plots of the EIR (1/COP) of the heat pump as a function of compressor speed (left) and condenser fan speed (right) for fixed zone air temperature and outdoor air temperature are shown in Figure 8. DV = heat pump electric input ratio (EIR), cooling rate, or power consumption Figure 8. Heat pump performance curves generated by the empirical models as a function of comrpessor speed (left) and condenser fan speed (right) for combinations of fixed zone air and outdoor air temperatures. References Aprea, C. and C. Renno Experimental Model of a Variable Capacity Compressor. International Journal of Energy Research 33: Armstrong, P.R., W. Jiang, D. Winiarski, S. Katipamula, L.K. Norford, and R.A. Willingham. 2009a. Efficient Low-Lift Cooling with Radiant Distribution, Thermal Storage, and Variable-Speed Chiller Controls – Part I: Component and Subsystem Models. HVAC&R Research 15(2): Armstrong, P.R., W. Jiang, D. Winiarski, S. Katipamula, and L.K. Norford. 2009b. Efficient Low-Lift Cooling with Radiant Distribution, Thermal Storage, and Variable-Speed Chiller Controls – Part II: Annual Energy Use and Savings. HVAC&R Research 15(2): ASHRAE ASHRAE Standard , Calorimeter Test Methods of Mass Flow Measurements for Volatile Refrigerants. Atlanta: American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc. ASHRAE ASHRAE Handbook – Fundamentals. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Benapudi, S. and J. Braun A Review of Literature on Dynamic Models of Vapor Compression Equipment. ASHRAE Research Project 1043-RP. DOE DOE 2 Reference Manual, Part 1, Version 2.1. Berkeley, California: Lawrence Berkeley National Laboratory. Gayeski, N Predictive Pre-Cooling Control for Low-Lift Radiant Cooling using Building Thermal Mass. Doctor of Philosophy in Building Technology dissertation. Massachusetts Institute of Technology. Gordon, J., and K.C. Ng Cool Thermodynamics. Cambridge International Science Publishing. United Kingdom. Hydeman, M., N. Webb, P. Sreedharan, and S. Blanc Development and Testing of a Reformulated Regression-Based Electric Chiller Model. ASHRAE Transactions 108(2) Hydeman, M., and K. Gillespie Tools and Techniques to Calibrate Electric Chiller Component Models. ASHRAE Transactions 108(2): Jin, H., and J.D. Spitler A Parameter Estimation Based Model of Water-to-Water Heat Pumps for Use in Energy Calculation Programs. ASHRAE Transactions 108(1) NIST NIST Reference Fluid Thermodynamic and Transport Properties Database (REFPROP): Version 8.0. NIST Standard Reference Database 23 Rasmussen, B.P Dynamic Modeling and Advanced Control of Air Conditioning and Refrigeration Systems. PhD Dissertation. University of Illinois at Urbana-Champaign. Shao, S., W. Shi, X. Li, and H. Chen Performance representation of variable-speed compressor for inverter air conditioners based on experimental data. International Journal of Refrigeration 27(2004): From Figure 8 it is evident that at low compressor speeds, low outdoor air temperatures, and high zone air temperatures the heat pump COP is as high as 5 to 10. This correspond s to low- lift operating conditions where COPs improve dramatically at low pressure ratio, as shown in Figure 9. The objective of low –lift cooling is to operatedin this range of high COP conditions more of the time through predictive control of a low-lift chiller pre-cooling thermal energy storage. Figure 9. Outdoor unit COP as a function of pressure ratio Acknowledgements The authors wish to acknowledge the Masdar Institute of Science and Technology for support of this research. The authors are also grateful for the support and advice of members of the Mitsubishi Electric Research Laboratory and the Pacific Northwest National Laboratory. Nicholas Gayeski is also thankful for the support of the Martin Family Society of Fellows for Sustainability. For more information about this work contact: Nick Gayeski, PhD