Liquid Volume Measuring Devices: The Graduated Cylinder and Buret.

Slides:



Advertisements
Similar presentations
Measuring Volume Temperature Mass.
Advertisements

Some Review… Did I learn that in Gen Chem I? CHM 1030.
Reading Graduated Cylinders Important Stuff!. Graduated cylinders are used to measure the volume of liquid samples and are available in many different.
Scientific Measurement. All measurements have a number value AND a unit.
Graduated Cylinders.
Measuring Reading the Meniscus Always read volume from the bottom of the meniscus at eye-level. The meniscus is the curved surface of a liquid in a narrow.
Pipetting Pipetting involves drawing a liquid into a pipet and allowing liquid to drain from the pipet in a controlled manner. Pipetting is used to quantitatively.
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Measuring Volume of Liquids Most common apparatus - measuring cylinder comes in different sizes, e.g 10 ml, 25 ml, 50 ml,
Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Volume Determination and Density Lab 3. Outline Reading a meniscus Volume determination and significant digits Balances Mathematical treatment of data.
Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of a liquid in a narrow cylindrical container.
Using Laboratory Equipment Chapter 3
LANGUAGE OF THE LAB Using Laboratory Tools Properly!
Unit 1: Introduction to Chemistry Please enjoy this free measurement Power Point. If you like the quality of my work, please stop by my TpT store for.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Significant Figures Number of digits believed to be correct by the person doing the measuring Includes 1 estimated digit Read to 1/10 the smallest division.
Making Measurements in the Lab  V Volume  Temperature  Mass Adapted from
Reading the Graduated Cylinder And All about the Meniscus.
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Some Common Laboratory Glassware Please be careful when using glassware in the laboratory. Wet glassware and wet gloves are slippery. Always read a volume.
Burette = (Am.) buret ; a graduated vertical glass tube used to deliver variable volumes of liquid or gas ; usually equipped with a stopcock to control.
Science Notebook All those details you need to know in order to do science.
Liquid Measurement Dr. Amani Elsayed.
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Reading: Chapter 2 – an informative review Chemical measurements: Tools of the trade – hardware and labs VISIT THE LAB Safety Lab notebook Introduction.
Liquid Volume Measurement Tools & Methods. Meniscus Water is adhesive… sticks to stuff. It “climbs” the glass. The curve formed is the meniscus. We Read.
Measuring  Volume  Temperature  Mass. Graduated Cylinders The glass cylinder has etched marks to indicate volumes, a pouring lip, and quite often,
Lab Equipment and Volume. Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated.
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Volume determination and density
 Most common for holding liquids  Hold solids or liquids that are unlikely to release gas or splatter if stirred or heated.  Beakers come in several.
General Laboratory Techniques Dry Lab Chemistry 1105.
Laboratory Glassware and equipment
Reading the Graduated Cylinder
Measuring Volume Temperature Mass.
Measuring Volume Temperature Mass.
How to do a Manual Titration
Measurement and Lab Equipment
Reading the Graduated Cylinder
Measuring Volume Temperature Mass.
Measurement Notes.
Measuring Liquid Volume
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Reading the Graduated Cylinder
Measuring Volume Meniscus Madness
Measurement of Volume Chapter 20.
Measuring Tools Measurement Tools Units Length Mass Volume Temperature
Measuring Volume Temperature Mass.
Reading: Chapter 2 – an informative review
Reading the Graduated Cylinder And all about the Meniscus!
Bellwork 1. Label each piece of equipment pictured below.
Introduction to Titration
Laboratory Techniques: Titration
How to do a Manual Titration
Measuring Volume Temperature Mass.
Did I learn that in Gen Chem I?
Science Tools Notes.
Common Laboratory Glassware
Reading the Graduated Cylinder And all about the Meniscus!
Experiment 1 Basic Laboratory Techniques Parts A, D, E, and an Unknown
Reading the Graduated Cylinder
Measuring Volume: Graduated Cylinders & Reading a Meniscus.
Measuring Volume Temperature Mass.
Practical Pharmaceutical Orientation
Laboratory Glassware.
Reading the Graduated Cylinder
Presentation transcript:

Liquid Volume Measuring Devices: The Graduated Cylinder and Buret.

Like weighing, measuring liquid volume is a fundamental and frequently encountered lab task. However, liquid volume is frequently measured using either a graduated cylinder or a buret.

As the name implies, a graduated cylinder is a cylindrical glass (or plastic) tube sealed at one end with a calibrated scale etched (or marked) on the outside wall. Graduated cylinders come in a range of sizes (volume capacities), and much like a measuring cup, volume is measured by adding liquid to the cylinder and comparing the liquid level to the graduated scale. The measured volume corresponds to the volume of liquid contained in the cylinder. Hence, the graduated cylinder and devices like it (volumetric flasks, Erlenmeyer flasks, and beakers) are classified as to-contain (TC) devices.

The volume of liquid in the graduated cylinder is obtained directly by reading the calibrated scale. In most situations, the liquid will be water or an aqueous solution. The liquid surface is curved (U-shaped) rather than horizontal due to the relatively strong attractive force between water and glass. (The curved surface is called the meniscus.) As a general rule, the bottom of the meniscus is taken as the liquid level in the cylinder (and any other volume measuring device). An error in reading a buret due to incorrect positioning of your eye is call a parallax error.

The scale divisions on a graduated cylinder are generally determined by its size. For example, the 50-mL graduated cylinder is divided into 1 mL increments. However, the scale of a 10-mL graduated cylinder is divided into 0.1 mL increments, and the scale of a 500-mL graduated cylinder is divided into 5 mL increments. 500 mL Graduated Cylinder 50 mL graduated Cylinder

The graduated cylinder scale is a ruled scale, and it is read like a ruler. The scale is read to one digit beyond the smallest scale division by estimating (interpolating) between these divisions. With a 50-mL graduated cylinder, read (and record) the volume to the nearest 0.1 mL The 500-mL graduated cylinder scale is read to the nearest milliliter (1mL). 50 mL graduated Cylinder 500 mL Graduated Cylinder ____18.0__ mL ____293__ mL

A buret is a scaled cylindrical tube attached to a stopcock (valve) A buret is a scaled cylindrical tube attached to a stopcock (valve). A buret is designed to dispense or transfer a precisely measured volume of liquid to another container. The volume of liquid dispensed is determined by reading and recording the buret scale which corresponds to the liquid level in the buret before any liquid is transferred, Vinitial (or Vi), and after the transfer is complete, Vfinal (or Vf). The volume of liquid transferred is obtained by difference (Vf - Vi) and it is sometimes designated as Vt. stopcock

Burets are available in a limited range of sizes; the most common size is 50-mL. The scale of a 50-mL buret is divided into 0.1 mL increments. Therefore, when the liquid level in a buret is read, it is read (and recorded) to the nearest 0.01 mL. Water or aqueous solutions are the most common liquids used with a buret, and like the graduated cylinder the bottom of the meniscus is taken as the liquid lever. The buret and devices like it (pipet and syringe) is classified as a to-deliver (TD) devices. ?? mL