NSA-7000 Stylish flush mount Network Sensors

Slides:



Advertisements
Similar presentations
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Advertisements

AC-SSC-1 Installation and operation manual
PYRO-X De-Ice control devices Technical presentation 2013.
Siemens Building TechnologiesRWD heatpump controllers Xavier Zabalegui/David Jefferson 1 January 2003 RWD Heat Pump controllers RWD Heat Pump Controllers.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
PYROCON12 De-Ice controller User Operation Presentation 2013.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
Smile training Smile_training_engl. Sept.02.ppt Honeywell Proprietary Jan. 31st, Smile Controller Family.
Settings & Adjustments. Settings & Adjustments.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
XS26-2 Expandable Safety Controller.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Zio™ TR70 LCD Wall Module Customer Training.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
Technical Introduction April Internal usage only 1 General Features  Self contained batch solution for small, standalone applications.  All functionality.
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
2 Wire Door Entry System (DES of MH BT offer)
The New Switch can replace all the Old Room Needed Controllers 1– Light Switches and Wall Dimmers 2– Air-conditioning Thermostat 3– Volume Control 4–
KNX Push-button Pro Confidential Property of Schneider Electric |
HVAC Programmable Controllers -PTU
1 Comparison of 100-B and 100-D Contactors B Contactors.
User Operation Presentation
Fan Coil Controller FC/S 1.1
VARLOGIC NRC12 Varmetric Controller
Cold-Chain Expert, Total Solution Quality Precision Service Value
A22N Series Pushbutton Switches/Indicators
C1300 advanced circular chart recorder
Lesson 5: Viewing and Printing Workbooks
System Network Structure
Reveal™ Touch Screen Product Overview
System Pilot Version 1.0.
ABB i-bus® KNX Valve Drive Actuator VAA/A
CLOSED-LOOP MOTOR SPEED SENSOR & CONTROLLER
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
Wireless 4 Buttons Touch Panel
HD SIGNAL CONDITIONER SERIES
Wireless 3 Buttons Touch Panel
MKTG 2016.
Open Minds ESL Electronic Shelf Label
Keypad Lockout - Available June 15, 2015
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Analog Room Command Module
Nematron® ePC II Series Product Launch
Programmable Logic Controllers (PLCs) An Overview.
De-Ice control devices
Product Training Module
IF13 series: Power cord with Input EMC Filter
Pressure Level Sensor OTT PLS
Customer Presentation
Technician Operation Presentation
HD SIGNAL CONDITIONER SERIES
Nematron® ePC II Series Product Launch
2N Access Unit 2.0 Multi-technology access control readers.
Total HVAC Control from anywhere Easy control that can save a fortune
Maxsony Technology Limited
PowerLogic™ offer for the basic metering market
A22N Series Pushbutton Switches/Indicators
Detailed information FOR INTERNAL USE ONLY! CUBE20.
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

NSA-7000 Stylish flush mount Network Sensors Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Stylish flush mount Network Sensors Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’

NSA 7000 Network Sensors flush mount Overview Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA 7000 Network Sensors flush mount Overview The new platform changes the look of our room sensors. NS-7000 Network Sensor NSA-7000 Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages

NSA 7000 Network Sensors flush mount Overview Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA 7000 Network Sensors flush mount Overview The Hardware platform provides: NSA7000 New Network Sensor (SA-Bus) Standard Version Black Optional Benefit Modern design Large display with Push buttons Thin profile 14 mm and square 86 x 86 mm design Flush mount, made to fit EU box White Front Panel, optional Black (MOQ500 pcs *) Configurable functions for SKU reduction and easy selection Combined Temperature and Humidity detection Consistent design between new generation of Room Sensors Flush mount European Box Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages

NSA-7000 User Interface Large Display Custom Display Fan Controls Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 User Interface Large Display Custom Display 40% of the front area Backlight with time-out No need of localization Show Set Point only option Show Humidity Set Point limits Show Units °C or F Temperature reading offset Fan Controls Set Point Control Depending on model Easy selection up / down of 0,5 °C Set Point mode ADJ or W/C configurable Occupancy Toggle OCC output ADJ 12 28 °C W/C -3 +3 Configurable Up to 5…35°C Up to -5 ...5°C SP MODE Keypad Lockable No lock Lock all keys Lock all keys except Occupancy Press and Hold 5 SEC to configure Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages

NSA7000 Network Sensor Overview Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA7000 Network Sensor Overview Network Sensor A7000 (NSA700) Designed for SA-BUS use same tool of current Network Sensors NS7000 Main Difference versus Current NS7000: Flush mount, larger display and low profile enclosure All models have Screw Terminal (ST) and Modular Jack (MJ) Local configuration via Display and pushbuttons: SA-BUS Address, can be done without open the sensor through the Display Configurable Set Point mode: Adjust or Warmer/Cooler (1 code can do both) Configurable Display to show Setpoint only instead actual temperature Mounting plate allows installation without open the device Locks Push buttons 4 Items codes for many configuration ST MJ Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ Company Confidential, do not disclose outside of the Company

NSA7000 Analog Sensors Items codes Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA7000 Analog Sensors Items codes NSA-FTD7003-0 Four buttons model NSA-FTB7003-0 Three buttons model Temperature Set Points ADJ or W/C Fan Speed Occupancy Connection MJ + ST Address #199-215 Temperature Set Points ADJ or W/C Occupancy Connection MJ + ST Address #199-215 NSA-FHR7103-0 Three buttons model NSA-FHN7001-0 Temperature and Humidity Set Points ADJ or W/C Occupancy Connection MJ + ST Address #199-215 Temperature and Humidity Connection MJ + ST Single Address #199 Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages

NSA7000 Network Sensors Installation Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA7000 Network Sensors Installation The NSA-7000 can be installed on rounded European boxes using the mounting plate included in the supply. Once installed the devices will cover completely the mounting plate and it will protrude from the wall of 14 mm only. A little screw keeps the device in place. Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages

NSA-7000 Ordering codes Table 1: NSA7000 series network – Standard Devices White Product code Color1 LCD Temperature Humidity2 Fan control Temp. adjustment3 °F/ °C scale toggle Occupancy override Screw terminal4 Address selection5 NSA-FHN7001-0 White No Yes Yes (±3%) N/A ST/MJ No (#199) NSA-FTD7003-0 Adj/WC NSA-FTB7003-0 NSA-FHR7103-0 Table 2: NSA7000 series network – Optional Black Devices Product code Color1 LCD Temperature Humidity2 Fan control Temp. adjustment3 °F/ °C scale toggle Occupancy override Screw terminal4 Address selection5 NSA-FHN7011-0 Black No Yes Yes (±3%) N/A ST/MJ No (#199) NSA-FTD7013-0 Adj/WC NSA-FTB7013-0 NSA-FHR7113-0 Note: There is MOQ (Minimum Order Quantity) requirement for black color. For models with humidity sensor, the humidity value can be displayed in LCD too Adj/WC means this model can work under Adjust 12 to 28°C or WC (Warmer/Cooler) +3 °C mode, selected in setting. All models equipped with both ST (Screw Terminal) and MJ (Modular Jack). The address can be selected from the display (199-215). Default address is 199. Recommended number of device in a mixed bus is four. NSA-7000 Network sensor Resource pages

NSA-7000 network sensor Benefit Large backlit Display in a low profile enclosure Display larger than 40% of front area, provides real time status of the environment with intuitive and clear user interface Display helps to meet building policy Sensors can be configured to show temperature, humidity or set point only, in addition the keypad can be locked to avoid misuse in public spaces. Flush Mount installation make it stylish Suitable for various installation boxes, flush mount offer low profile of only 14 mm outside the wall. Customize colors to meet customer needs The front panel of the sensor can be white or customized in black or other colors with a minimum quantity. Programmable SA Bus Address. User can easy define and read the communication address via push button, without opening and disconnecting the device. Mounting plate protection cap The mounting plate allows installation without opening the sensor. The removable and repositionable protection cap protects the sensor during commissioning or painting. Both avoid the risk of component damages during installation Configurable options reduce stock need Setpoint functionality Adjust or Warmer/Cooler can be configured from the display during the installation. Easy Wiring with MJ and ST options All NSA7000 models offer both type of connections: Modular Jack (MJ) and Screw terminal (ST). NSA-7000 Network sensor Resource pages

NSA-7000 Technical Specification Supply Voltage 9.8 to 16.5 VDC; 15VDC nominal (from SA Bus) Current consumption 35mA maximum Terminations Modular jack and screw terminal block Sensor addressing All models with factory set address 199. NSA-FTD70X3-0, NSA-FTB70X3-0 and NSAFHR71X3-0 can set address from 199 to 215 in setting page Wire size Modular jack: 24 AWG or 26 AWG (0.5 or 0.4 mm diameter) recommended; Three twisted pair (six conductors) Screw terminal block: 18-22 AWG (1.0-0.6 mm diameter); 22AWG (0.6 mm diameter) recommended Communication rate Auto-detect: 9.6k, 19.2k, 38.4k or 76.8k bps Mounting Flush-mounted Temperature measurement range 0-40 °C Humidity measurement range Full range: 0-100% RH Temperature accuracy ±0.5℃ (±1oF) Humidity accuracy ±3%RH Default temperature set point adjustment range Default Adjust Range: 12-28 °C, max configurable 10-30 °C in 0.5 °C increments Default W/C Range: -3 to +3 °C, max configurable + 0,5 to + 5 °C in 0.5 °C increments Ambient conditions Operating: 0-40 °C with 10-90% RH, non-condensing Storage: -20 to 60 °C with 5-95% RH, noncondensing Shipping weight Approx. 300g Compliance CE mark RCM mark, Australia/NZ emissions compliance RoHS, REACH, WEEE Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’

Thank You NSA-7000 Network sensor Resource pages