VNX Storage Report Project: Sample VNX Report Project ID:

Slides:



Advertisements
Similar presentations
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
Advertisements

1© Copyright 2013 EMC Corporation. All rights reserved. ACCELERATING MICROSOFT EXCHANGE PERFORMANCE WITH EMC XtremSW Cache EMC VNX Storage and VMware vSphere.
IBM 1350 Cluster Expansion Doug Johnson Senior Systems Developer.
VSphere vs. Hyper-V Metron Performance Showdown. Objectives Architecture Available metrics Challenges in virtual environments Test environment and methods.
SQL Server, Storage And You Part 2: SAN, NAS and IP Storage.
IBM® Spectrum Storage Virtualize™ V V7000 Unified in a nutshell
1 Andrew Hanushevsky - HEPiX, October 6-8, 1999 Mass Storage For BaBar at SLAC Andrew Hanushevsky Stanford.
STORAGE Virtualization
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
2730/2730T/5730 Performance Comparison 20 May 2008.
11 Capacity Planning Methodologies / Reporting for Storage Space and SAN Port Usage Bob Davis EMC Technical Consultant.
1 © Copyright 2009 EMC Corporation. All rights reserved. Agenda Storing More Efficiently  Storage Consolidation  Tiered Storage  Storing More Intelligently.
Copyright © 2014 EMC Corporation. All Rights Reserved. Advanced Storage Concepts Upon completion of this module, you should be able to: Describe LUN Migration.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
Oracle Storage Overview Tomáš Vencelík – Storage sales leader.
Nexenta Proprietary Global Leader in Software Defined Storage Nexenta Technical Sales Professional (NTSP) COURSE CONTENT.
Slide 1 DESIGN, IMPLEMENTATION, AND PERFORMANCE ANALYSIS OF THE ISCSI PROTOCOL FOR SCSI OVER TCP/IP By Anshul Chadda (Trebia Networks)-Speaker Ashish Palekar.
Module – 4 Intelligent storage system
Storage Systems Market Analysis Dec 04. Storage Market & Technologies.
Experience with the Thumper Wei Yang Stanford Linear Accelerator Center May 27-28, 2008 US ATLAS Tier 2/3 workshop University of Michigan, Ann Arbor.
Switched Storage Architecture Benefits Computer Measurements Group November 14 th, 2002 Yves Coderre.
5/8/09 Titanium Performance Update 2 Dot Hill Confidential.
© 2011 IBM Corporation Sizing Guidelines Jana Jamsek ATS Europe.
ONStor Pantera 3110 ONStor NAS. Copyright 2008 · ONStor Confidential Pantera 3110 – An Integrated Channel only NAS  Integrated standalone NAS system.
1EMC CONFIDENTIAL—INTERNAL USE ONLY FAST VP and Exchange Server 2010 Don Turner Consultant Systems Integration Engineer Microsoft TPM.
1© Copyright 2012 EMC Corporation. All rights reserved. EMC VNX5700, EMC FAST Cache, SQL Server AlwaysOn Availability Groups Strategic Solutions Engineering.
TS7700 Performance and Capacity Daily charts only Enter Description, Month & Year in this Text Box.
TS7700 Performance and Capacity Daily and Hourly charts Enter Description, Month & Year in this Text Box.
© Copyright 2004 Instrumental, Inc I/O Types and Usage in DoD Henry Newman Instrumental, Inc/DOD HPCMP/DARPA HPCS May 24, 2004.
Jérôme Jaussaud, Senior Product Manager
When value, performance, and scale matter. Your company Partners Where we are today? 2 Suppliers Customers Accounting Engineering Marketing Finance HR.
Extending Auto-Tiering to the Cloud For additional, on-demand, offsite storage resources 1.
Ayman El-Ghazali Senior Microsoft.
EonStor DS Specifications summary 2 EonStor DS 3000 Advantages High performance High scalability Easy upgradable host interface module Rich data.
System Storage TM © 2007 IBM Corporation IBM System Storage™ DS3000 Series Jüri Joonsaar Tartu.
EonStor DS series disk arrays
E2800 Marco Deveronico All Flash or Hybrid system
About ProLion CEO, Robert Graf Headquarter in Austria
Connectrix Storage Networking
EonStor DS 1000.
Managing HP Enterprise Virtual Array
Chapter 10: Mass-Storage Systems
EonStor DS 2000.
The demonstration of Lustre in EAST data system
STEC Solutions for NetApp Environments
Direct Attached Storage and Introduction to SCSI
C VCE
Optimize Storage with BMC TrueSight Capacity Optimization
Virtual Memory Main memory can act as a cache for the secondary storage (disk) Advantages: illusion of having more physical memory program relocation protection.
Hitachi Data Systems Network Storage Systems
Direct Attached Storage and Introduction to SCSI
Upgrading to Microsoft SQL Server 2014
Storage Team (Controller Performance) Aggregate Utilization
Oracle Storage Performance Studies
XtremIO Storage Array Asset Profile
SQL Storage Fundamentals for Azure IaaS
Unity Storage Array Profile
ASM-based storage to scale out the Database Services for Physics
CS 140 Lecture Notes: Technology and Operating Systems
Assessment Findings System Professional <Insert Consultant Name>
CS 140 Lecture Notes: Technology and Operating Systems
ظرفیت سنجی دستگاه های ذخیره ساز در مراکز داده
Persistence: hard disk drive
SAN Monitoring BMC and Sentry solution to detect faults, proactively monitor the performance and capacity of a multi-vendor SAN environment.
SAN Monitoring BMC and Sentry solution to detect faults, proactively monitor the performance and capacity of a multi-vendor SAN environment.
SAN Monitoring BMC and Sentry solution to detect faults, proactively monitor the performance and capacity of a multi-vendor SAN environment.
Cost Effective Network Storage Solutions
About ProLion CEO, Robert Graf Headquarter in Austria
DataOptimizer Transparent File Tiering for NetApp Storage Robert Graf
Hybrid Buffer Pool The Good, the Bad and the Ugly
Presentation transcript:

VNX Storage Report Project: Sample VNX Report Project ID: 123456 Prepared For: Prepared By: Created: 12.01.2017 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Summary - Peak Latency of 7.7 ms was observed. 94% of your IOs were serviced in 2.5 ms or less. - 85.3% of IOs are going to 14.7% of LUNs. - We found a storage density of 7 TB of allocated (LUN) data per shelf, with 174 TB of LUN data across 607 drives and 26 enclosures. Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

VNX_Array1 Summary – Hardware Overview Software Features Input Data Serial No. CKM0000000000 Model No. VNX_5800 Software Level 5.33.155 Cache (GB) 64 No. DAEs 26 Active Drives 607 Inactive Drives 43 Empty Slots Snap View Yes Mirror View Recover Point SAN Copy Input Data Emulations Connectivity Configuration File Date 2017-12-01 Performance Start 201-11-28 11:32 Performance End 2017-12-01 04:17 Performance Interval (mins) 5 File No Block Yes FC 4GB FC 8GB FC 16GB 24 1 GigE 10 GigE iSCSI Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Capacity Summary by Drive Type - VNX_Array1 Name Model Disk (TIB) SSD (TIB) Usable (TIB) Used (TIB) Utilization (%) VNX_Array1 VNX_5800 251.93 6.61 212.54 204.94 96 Drive Type Size (GiB) Number of Drives % of IOPS Raw Capacity (TB-b10) Raw Capacity (%) SSD_SAS 10G 200GB 183 37 70.1 7.4 2.12 SAS 10K 600GB 536 333 23.08 199.8 57.18 SAS 10G 600GB 237 6.82 142.2 40.7 Total Raw Capacity (TB-b10) (%) 349.4 100 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Array Profile Details

Array Capacity - VNX_Array1 TiB = base-2 engineering terrabytes (1,099,511,627,776 bytes) Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Ports Name Speed (GB/sec) Read MB/sec – 95th Write MB/sec – 95th Port 0 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] 8 64 13 138 10 Port 1 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10] Port 1 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] Port 10 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] 70 44 40 36 Port 11 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] Port 2 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] 67 17 143 12 GB = Gigabits per second Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Ports Name Speed (GB/sec) Read MB/sec – 95th Write MB/sec – 95th Port 3 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] 8 Port 4 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] 50 60 74 Port 5 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] Port 6 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] 46 58 48 Port 7 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] GB = Gigabits per second Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Ports Name Speed (GB/sec) Read MB/sec – 95th Write MB/sec – 95th Port 8 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] 8 70 44 41 36 Port 9 [FC; 00:00:00:00:00:00:1E:00:00:00:00:00:00:1E:10 ] GB = Gigabits per second Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Performance Profile - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Array Profile Metric - VNX_Array1 Name Value # Disks 607 Disk (TiB) 298 SSD (TiB) 6 LUN (TiB) 199 LUN Used (TiB) 170 LUN Skew 85% of IOPS/15% of LUNS Front End MB/sec - max 2,196 Date Time - Peak 2017-12-01 23:43:05 IOPS at Peak 29,833 Read % at Peak 45.00 Read Size (KB) at Peak 41.84 Write Size (KB) at Peak 29.49 MB/sec at Peak 1,020 Latency (ms) at Peak 1.2 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

5 Year Growth Projection - VNX_Array1 At 20% growth, usable capacity will be exceeded in less than 1 year. Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Front End Latency - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Front End Bandwidth - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Top 5 Clients by IOPS - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Front End IOPS vs Back End IOPS - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Top 5 Clients by IOPS - VNX_Array1 #LUNs Used (TiB) Peak IOPS Response Time (ms) Front End MB/sec Read % Avg IO Size (KB) Client1 180 25.69 18,433 0.36 283 46.73% 29.38 Client2 33 5.83 10,184 0.19 23 89.21% 19.95 Client3 28 49.77 10,026 2.55 261 30.54% 116.77 Client4 102 51.77 7,355 1.7 60 34.39% 35.21 Client5 26 1.95 4,288 0.59 12 65.81% 12.67 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

IO Size and Read Percent - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

IOPS Thresholds - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Back End Activity By Pool - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Back End Activity By Pool - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Back End Activity By Pool - VNX_Array1 Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Total Queue Length - VNX_Array1 Shows the total busy queue length across both SPs. Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Top Clients and LUNs

Top 15 LUNs by IOPS - VNX_Array1 LUN Name Front End IOPS - max Front End MB/sec - max Avg IO Size (KB) - avg Response Time (ms) - max Response Time (ms) -avg Avg Queue Length - max Read % - avg LUN 1 6,006 96 22.56 6 1 10.8 70.72% LUN 2 5,615 63 10.13 3 4.1 26.95% LUN 3 5,053 190 55.09 5 3.9 98.96% LUN 7 3,015 366 58.65 5.4 82.66% LUN 6 2,609 23 18.68 4 0.6 90.28% LUN 8 2,601 24 18.49 90.58% LUN 5 2,575 19.04 90.1% LUN 20 2,448 44 16.71 1.9 73.53% LUN 27 2,394 18.66 2 0.5 90.52% LUN 24 2,330 15 7.97 0.8 2.02% LUN 32 2,006 8.29 2.11% LUN 33 1,942 35 20.36 2.8 50.45% LUN 11 1,941 8.22 0.7 2.08% LUN 16 1,928 14 7.92 2% LUN 40 1,697 40 32.8 0.9 71.73% Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Top 15 LUNs by MBPS - VNX_Array1 LUN Name Front End IOPS - max Front End MB/sec - max Avg IO Size (KB) - avg Response Time (ms) - max Response Time (ms) -avg Avg Queue Length - max Read % - avg LUN 1 741 403 394.2 8 2 4.6 19.2% LUN 2 3,015 366 58.65 6 1 5.4 82.66% LUN 3 680 349 178.73 37 5 7.8 33.4% LUN 7 5,053 190 55.09 3.9 98.96% LUN 6 264 131 168.8 16 4 3.85% LUN 8 98 135.55 18 3.8 27.18% LUN 5 6,006 96 22.56 10.8 70.72% LUN 20 600 95 107.83 28 32.26% LUN 27 1,360 89 22.91 3 1.3 26.47% LUN 24 1,370 84 78.45 0.8 96.68% LUN 32 214 74 273.85 26 7 20.48% LUN 33 898 73 36.28 1.8 49.6% LUN 11 593 72 40.02 0.6 29.84% LUN 16 594 71 49.22 0.7 38.92% LUN 40 381 70 88.1 46 8.9 31.31% Copyright © 2018 Dell Inc. VNX Version 2017-01-04 PowerPointGeneratorV2 2018.01.22.uat-001

Conclusion

Common Summary: Inventory, Capacity and Workload Inventory and Capacity Summary Workload Summary Peak IOP Measurements Workload Summary 95th Percentile Measurements Serial No. CKM0000000000 Model No. VNX_5800 Software Level 5.33.155 Cache 64 Total No. Drives 607 No. Flash Drives 37 No. Spinning Drives 570 Flash Usable (TiB) 6.61 Spinning Disk Usable (TiB) 298.36 Subscription % 93.67% Subscription Capacity (TiB) 199.07 Used Capacity TiB 204.94 Usable Capacity TiB 212.54 LUN Skew - Avg IO 85.3% Configuration File Date 2017-12-01 Performance Start 2017-11-28 11:28:31 Performance End 2017-12-01 04:17:36 Performance Interval (mins) 5 Peak IOPS: Date Time 2017-12-01 23:43:05 Peak IOPS: IOPS 29833 Peak IOPS: Read % 45 Peak IOPS: Avg. Read Size (KB) 41.84 Peak IOPS: Avg. Write Size (KB) 29.49 Peak IOPS: MB/s 1020.34 Peak IOPS: Latency (ms) 1.2 95th IOPS: Date Time 2017-11-29 22:03:20 95th IOPS: IOPS 21,988 95th IOPS: Read % 45 95th IOPS: Avg. Read Size (KB) 44.23 Workload Summary Peak MB/s Measurements Peak MB/s: Date Time 2017-12-01 23:32:45 Peak MB/s: IOPS 17332 Peak MB/s: Read % 47 Peak MB/s: Avg. Read Size (KB) 225.23 Peak MB/s: Avg. Write Size (KB) 46.19 Peak MB/s: MB/s 2196.49 Peak MB/s: Latency (ms) 7.2