Dynamic Behavior and Stability of Closed-Loop Control Systems

Slides:



Advertisements
Similar presentations
Dynamic Behavior of Closed-Loop Control Systems
Advertisements

Feedforward and Ratio Control
Closed-Loop Transfer Functions
Feedback loop (CV changes input) SP Controller Gc Plant Gp Sensor Gs E MV (Manipulated Variable CV Controlled Variable +-+- S.
Dynamic Behavior of Closed-Loop Control Systems
Automation I. Introduction. transmitter actuator Structure of control system Process or plant Material flow sensorstransducers actuating units actuating.
Chapter 4 Modelling and Analysis for Process Control
Ratio Control Chapter 15.
Dynamic Behavior of Closed-Loop Control Systems Chapter 9.
Control System Instrumentation
CHE 185 – PROCESS CONTROL AND DYNAMICS
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Chapter Summer 2. Comparator 3. Block Blocks in Series
Dynamic Behavior and Stability of Closed-Loop Control Systems
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
CONTROL SYSTEM INSTRUMENTATION
Dynamic Behavior and Stability of Closed-Loop Control Systems
Chapter 11 1 Closed-Loop Responses of Simple Control Systems In this section we consider the dynamic behavior of several elementary control problems for.
Control System Instrumentation
Introduction to Process Control
Chapter 8. The PID Controller Copyright © Thomas Marlin 2013
Chapter 7 PID Control.
Lecture 5: PID Control.
Hairul Nazirah bt Abdul Halim
Anis Atikah Ahmad CHAPTER 11: Dynamic Behaviour & Stability of Closed-Loop Control Systems Anis Atikah Ahmad
Transfer Functions Chapter 4
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Control System Instrumentation
Block Diagrams and Steady State Errors. Topics Block diagrams to represent control systems Block diagram manipulation Example Steady State Error.
ERT 210/4 Process Control Hairul Nazirah bt Abdul Halim Office: CHAPTER 8 Feedback.
2.Mathematical Foundation 2.1 The transfer function concept  From the mathematical standpoint, algebraic and differential or difference equations can.
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
(Transfer functions and Block Diagrams)
ERT 210/4 Process Control & Dynamics DYNAMIC BEHAVIOR OF PROCESSES :
TRANSFER FUNCTION Prepared by Mrs. AZDUWIN KHASRI.
Anis Atikah Ahmad CHAPTER 11: Dynamic Behaviour & Stability of Closed-Loop Control Systems Anis Atikah Ahmad
Chapter 11 1 ERT 210/4 Process Control CHAPTER 11 DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS.
Rules to reduce block diagrams Transfer Function Problem solving
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control Ms Anis Atikah Ahmad
ET 438a Automatic Control Systems Technology Lesson 1: Introduction to Control Systems Technology 1 lesson1et438a.pptx.
Transfer Functions Convenient representation of a linear, dynamic model. A transfer function (TF) relates one input and one output: The following terminology.
Control System Instrumentation
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control
Chapter 1: Overview of Control
Feedback Controllers Chapter 8
Automatic control systems I. Nonlinearities in Control System
Transfer Functions Chapter 4
CHAPTER V CONTROL SYSTEMS
Workshop for Flipped Class
Automatic control systems I
Professor Robert L. Heider, PE
CHAPTER VI BLOCK DIAGRAMS AND LINEARIZATION
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Controller Tuning: A Motivational Example
Control System Instrumentation
Process Control Engineering
Enhanced Single-Loop Control Strategies
Control System Instrumentation
Features of PID Controllers
G1 and G2 are transfer functions and independent of the
Important Properties of Laplace Transforms
Introduction to Process Control
Stability of Closed-Loop Control Systems
Linearization of Nonlinear Models
Feedback Controllers Chapter 8
Proportional Control and Disturbance Changes
PID Controller Design and
Dynamic Behavior Chapter 5
G1 and G2 are transfer functions and independent of the
Presentation transcript:

Dynamic Behavior and Stability of Closed-Loop Control Systems In this chapter we consider the dynamic behavior of processes that are operated using feedback control. This combination of the process, the feedback controller, and the instrumentation is referred to as a feedback control loop or a closed-loop system. Block Diagram Representation To illustrate the development of a block diagram, we return to a previous example, the stirred-tank blending process considered in earlier chapters.

Figure 11.1 Composition control system for a stirred-tank blending process.

Next, we develop a transfer function for each of the five elements in the feedback control loop. For the sake of simplicity, flow rate w1 is assumed to be constant, and the system is initially operating at the nominal steady rate. Process In section 4.3 the approximate dynamic model of a stirred-tank blending system was developed: where

Figure 11.2 Block diagram of the process.

Composition Sensor-Transmitter (Analyzer) We assume that the dynamic behavior of the composition sensor-transmitter can be approximated by a first-order transfer function: Controller Suppose that an electronic proportional plus integral controller is used. From Chapter 8, the controller transfer function is where and E(s) are the Laplace transforms of the controller output and the error signal e(t). Note that and e are electrical signals that have units of mA, while Kc is dimensionless. The error signal is expressed as

or after taking Laplace transforms, The symbol denotes the internal set-point composition expressed as an equivalent electrical current signal. This signal is used internally by the controller. is related to the actual composition set point by the composition sensor-transmitter gain Km: Thus

Figure 11.3 Block diagram for the composition sensor-transmitter (analyzer).

Current-to-Pressure (I/P) Transducer Because transducers are usually designed to have linear characteristics and negligible (fast) dynamics, we assume that the transducer transfer function merely consists of a steady-state gain KIP: Control Valve As discussed in Section 9.2, control valves are usually designed so that the flow rate through the valve is a nearly linear function of the signal to the valve actuator. Therefore, a first-order transfer function usually provides an adequate model for operation of an installed valve in the vicinity of a nominal steady state. Thus, we assume that the control valve can be modeled as

Figure 11.5 Block diagram for the I/P transducer. Figure 11.6 Block diagram for the control valve.

Figure 11.7 Block diagram for the entire blending process composition control system.

Closed-Loop Transfer Functions The block diagrams considered so far have been specifically developed for the stirred-tank blending system. The more general block diagram in Fig. 11.8 contains the standard notation: Y = controlled variable U = manipulated variable D = disturbance variable (also referred to as load variable) P = controller output E = error signal Ym = measured value of Y Ysp = set point internal set point (used by the controller)

Figure 11.8 Standard block diagram of a feedback control system.

Yu = change in Y due to U Yd = change in Y due to D Gc = controller transfer function Gv = transfer function for final control element (including KIP, if required) Gp = process transfer function Gd = disturbance transfer function Gm = transfer function for measuring element and transmitter Km = steady-state gain for Gm