Comparison of Film v. Digital Image Display. Process of data capture All image recording systems rely on differential absorption within the patient to.

Slides:



Advertisements
Similar presentations
DIGITAL RADIOGRAPHY.
Advertisements

Charge Couple Devices Charge Couple Devices, or CCDs operate in the charge domain, rather than the current domain, which speeds up their response time.
Digital Imaging with Charge- coupled devices (CCDs)
Monitors and Sound Systems
RAD 350 Chapter 16 Digital Radiography Many types/names for the digital imaging processes and devices.
The Field of Digital Radiography
Digital Radiography.
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Digital Radiographic Imaging 101
Digital Imaging and Image Analysis
1 DIGITAL RADIOGRAPHY. 2 Digital Radiography A “filmless” imaging system introduced in 1987 Digital radiography uses an electronic sensor, instead of.
Digital Imaging CHAPTERS 1, 4-7 CARTER.
DIGITAL IMAGE PROCESSING CMSC 150: Lecture 14. Conventional Cameras  Entirely chemical and mechanical processes  Film: records a chemical record of.
Basic Concepts of Other Imaging Modalities
Optical Density and Brightness
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
Direct Digital Radiography or Direct Capture Radiography Bushong Ch. 27.
Elsevier items and derived items © 2008 by Mosby, Inc
Digital Image Characteristic
Computed Radiography and Digital Radiography
Unit III Creating the Image. Unit III Creating the Image.
Chapter 6: Digital Radiographic Imaging
Computers in Imaging Q & A Robert Metzger, Ph.D..
SPECIAL IMAGING/ADVANCED IMAGING INTRODUCTION TO DIGITAL RADIOGRAPHY
DIGITAL PROJECTION RADIOGRAPHY COMPUTED RADIOGRAPHY
Image Quality Radiographic Resolution.
Stacy kopso, M.Ed., rt(r)(m) ODIA digital Academy, arrt
Digital Radiology. 2 Aim : To become familiar with the digital imaging techniques in projection radiography and fluoroscopy.Aim : To become familiar with.
© 1999 Rochester Institute of Technology Introduction to Digital Imaging.
1 Digital Radiography Fall filmless’ radiology departments Diagnostic radiographers have traded their film and chemistry for a computer mouse.
Computed Radiography.
Rad Tech 265 More Digital Imaging. Digital Fluoroscopy Radiation dose –Patient dose for DF is significantly less than conventional fluoro At 7.5 pulses/second.
Digital Imaging. acronyms 1.PSP 2.CRT 3.ADC 4.IP 5.CR 6.DR 7.PACS 8.SNR 9.CNR 10. CCD 11. FOV 12. LUT 13. DICOM 14. RIS 15. HIS 16. TFT 17. DQE 18. DAP.
Factors affecting CT image RAD
Computed Radiography By Prof. Stelmark. Presently, an acceleration in the conversion from screen-film radiography (analog) to digital radiography (DR)
Digital Radiography and PACS By Professor Stelmark.
Elements of DR Imaging Systems
Things they never tell you when the equipment is installed REV 11/2008
DIGITAL IMAGE PROCESING NASA LUNAR AND PLANETARY EXPLORATION.
Review CR & DIGITAL IMAGING (1) 2012 – RT 244 wk 15
Registry Review Digital Imaging Considerations (Image Production and Evaluation)
Digital Imaging.
Digital Imaging Fundamentals Ms. Hema C.R. School of Mechatronic Engineering.
Chapt. 25 Computed Radiography Digital terms are NOT uniform, but vary from one brand to the next!
IMAGE RECEPTORS. Follow the Sequence- Film System Tube Tube Patient Patient (bucky) or non-bucky (bucky) or non-bucky Cassette Cassette INTENSIFYING SCREEN.
RAD 254 Chapt. 26 Digtal Imaging Many types/names for the Digital imaging to come.
DIGITAL IMAGING.
IMAGE ACQUISITION FILM SCREEN SYSTEM. PROCESSING THE LATENT IMAGE AUTOMATIC AUTOMATIC DARKROOM PROCESSOR DARKROOM PROCESSOR DAYLIGHT PROCESSOR DAYLIGHT.
Digital Radiographic Image Processing and Manipulation Chapter 7.
Digital Radiology Dr M A Oghabian Medical Physics Group Tehran University of Medical Sciences
Image Receptor Unsharpness By Professor Stelmark.
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
DIGITAL RADIOGRAPHY.
Direct Digital Radiography or Direct Capture Radiography
Acronyms. A SEQUENCE OF COMPUTER OPERATIONS FOR ACCOMPLISHING A SPECIFIC TASK Algorithm.
Tube Exposure Factors Math Technique Contrast and Density
Copyright © 2012, 2006, 2000, 1996 by Saunders, an imprint of Elsevier Inc. 1 Digital Imaging Instead of Radiography.
Comparison of Film v. Digital Image Display
Imaging Characteristics
Digital Imaging.
Rad Tech 265.
Chapter I, Digital Imaging Fundamentals: Lesson II Capture
כיצד נרכשת התמונה בסרט הרנטגני?
Digital Imaging CHAPTERS 1, 4-7 CARTER.
COMPUTED RADIOGRAPHY -Dr.SHEFALI MESHRAM
Chapter 6 Cassetteless Equipment and Image Acquisition
Digital Imaging.
Digital Imaging.
Presentation transcript:

Comparison of Film v. Digital Image Display

Process of data capture All image recording systems rely on differential absorption within the patient to produce a radiographic image Each system analog (film/screen) versus digital (CR and DDR) records photon intensity and displays the data. –Differences in photon density become radiographic contrast

Radiographic Contrast Radiographic contrast is dependent on subject contrast and technical factors –Subject contrast is basically fixed for each patient. Within certain body/organ systems we can alter subject contrast by introducing contrast media. Some technical factors include; –kVp –Grid ratio –Screen speed –Processor temperature Altering technical factors can improve or degrade radiographic contrast.

Film Films produce an analog image that allows edges to gradually blend into one another. This is how we see images normally. Conversely, digital images are broken up into pixels (tiny squares). Because the image consists of pixels there is an inherent loss of spatial resolution when compared to analog film. –2.5 – 5 lp/mm versus 10 lp/mm

Computed Radiography Photostimulable plate (PSP) –Barium-fluorohalide doped with europium When the PSP is struck by a photon electrons are released in the crystal lattice and stored in F centers within the lattice In the CR reader, a helium-neon laser (red light) stimulates the crystals of the PSP. Once stimulated the crystals emit blue- violet light.

The amount of light emitted is proportional to the amount of radiation absorbed by the PSP. The emitted light is read by a photomultiplier tube within the CR reader producing an electronic signal. The electronic signal is then fed through an analog-to-digital converter (ADC usually 12 bit) producing a digital signal. Essentially, the PSP is a OSL radiation monitor

ADC While converting the analog signal to a digital the ADC also breaks the pieces or squares that represent pixels in the final image.

Digital Radiography (DR) Direct DR –X-ray photons are absorbed by the DR plate. The active ingredient is usually amorphous selenium. The a-Se is ionized by the photons and the released electrons are stored in the TFT (thin film transistor) array. The TFT consists of multitude of individual elements that represent the pixels of the final image

Direct TFT

Indirect DR –Similar to direct DR but x-ray photons are converted to light photons (cesium iodide) and then pass through a photo-multiplier tube coupled with amorphous silicon. Cesium iodide crystals resemble needles in appearance resulting in very little light spread and high spatial resolution.

Indirect DR w/CCD

Indirect DR w/CMOS

Indirect DR Deterioration of image quality due to light diffusion

DeviceActive IngredientGrayscale/ dynamic range Processor Film/ Screen Phosphorescent screens and silver halide film emulsion 1000Wet or dry chemical action CRBarium fluorobromide doped with europium 14 bit Helium-neon red laser stimulates the PSP to emit light Direct DRAmorphous selenium14 to 16 bit shades of gray Indirect DRCesium iodide scintillator coupled with amorphous silicon 14 to 16 bit shades of gray

Film/screen Optical density ranges from 0 to 3 –This represents a range of 3 orders of magnitude or –View boxes can only display 30 shades of gray Film/screen grayscale is 1000

CR Four orders of magnitude are possible –10000 shades of gray CT and MR –12 bit or 4096 CR and DR –14 bit or Digital Mammography –16 bit or shades of gray

Contrast Resolution Principal descriptor –Grayscale –Dynamic range

Window level Window and leveling of the digital image allows us to see the entire grayscale of the digital image. Even though the eye is limited to 30 shades of gray by manipulating the window width and level we can determine where the 30 shades occur. We determine the center point of the 30 shades, level, and the width is how many grays will be displayed.

Window Width and Level

Processing the Image Image pre-processing –Find the pertinent image (histogram) –Scale data to appropriate range Contrast enhancement –Anatomy specific gray scale manipulation Spatial frequency enhancement

Raw Image Inherent subject contrast displayed Contrast inverted PSL signal amplitude log amplified

Scaled and inverted: Unprocessed image Preprocessed raw image

Contrast Enhancement Optimize image contrast via non-linear transformation curves Unprocessed images have linear subject contrast –Gradiation processing – Fuji –Tone scaling – Kodak –MUSICA - Agfa

Contrast Enhancement

Contrast enhanced Scaled and inverted: Unprocessed image

CsI crystals

Spatial Resolution and Monitor Performance In the analog environment, spatial resolution is a affected by SID, OID, RSV, FFS, and type of film to name a few. In the digital domain, the viewing monitor also affects spatial resolution as well as contrast resolution or dynamic range.

Monitor Factors Affecting Image Quality Monitor brightness –The brighter the monitor the better the image quality Color v/ B & W –For CR and DR color monitors do not offer enough dynamic range Matrix size –Most PC monitors are 1024 x 1280 or 1200 x These will allow you to view CT and MR at resolution.

Diagnostic Monitors Matrix size –2048 x 2560 at minimum Black and white not color Brightness –600 cd/m 2 v 300 cd/m 2