Atomic Force Microscope (AFM)

Slides:



Advertisements
Similar presentations
Scanning Probe Microscopy
Advertisements

Scanning Probe Microscopy ( STM / AFM )
Scanned-proximity Probe Microscopy (SPM) Background Emphasis on Atomic Force Microscopy (AFM) Reading SPM Features AFM Specifics AFM Operation (Conceptual)
The Principle of Microscopy : SEM, TEM, AFM
SCANNING PROBE MICROSCOPY By AJHARANI HANSDAH SR NO
Lecture 10. AFM.
Introduction to nano-scale materials imaging techniques: Physical principle and operation. 1 Lec. (6)
Activities during UK-Japan Young Scientist Workshop Dr Riz Khan Room 31DJ02, x6062, Advanced Technology Institute University.
Nanomechanical Detection of Living Cell Surface April 10, 2006 Joseph Abel USU Dept of Physics Living SH-SY5Y Neuroblastoma Cell
Microscopy as a Means for Nano-Characterization
Basic Imaging Modes Contact mode AFM Lateral Force Microscopy ( LFM)
November 14, 2005EEBE 512/ENEL Dr. KE Jones Lecture 22: Chapter 4: Surface Characterization in Biomaterials and Tissue Engineering Really just a.
Sample laser cantilever quadrant photodetector tip AFM measures x, y, and z dimensions. The AFM works by scanning a silicon or silicon nitride tip, with.
Atomic Force Microscopy: characterization of surface topography Andrius Martinavičius.
Atomic force microscopy Jiří Boldyš. Outline Motivation Minisurvey of scanning probe microscopies Imaging principles Ideas about application of moment.
UNIT IV LECTURE 61 LECTURE 6 Scanning Probe Microscopy (AFM)
Atomic Force Microscopy
Notre Dame extended Research Community 1 The Atomic Force Microscope Michael Crocker Valerie Goss Rebecca Quardokus Natalie Wasio.
Get to the point!. AFM - atomic force microscopy A 'new' view of structure (1986) AlGaN/GaN quantum well waveguide CD stamper polymer growth surface atoms.
Atomic Force Microscop (AFM) 3 History and Definitions in Scanning Probe Microscopy (SPM) History Scanning Tunneling Microscope (STM) Developed.
Atomic Force Microscopy
1 Challenge the future Feasibility study for AFM probe calibration using the probe’s electrostatic pull-in instability Laurens Pluimers Supervisors: Dr.ir.
Atomic Force Microscopy
Copyright © 2005 SRI International Scanning Probe Microscopy “Seeing” at the nanoscale.
NATSYCO. microscopy Optical microscopy Electron microscopy Scanning probe microscope.
Scanning Tunneling Microscope (STM) x feedback regulator high voltage amplifier z y I Negative feedback keeps the current constant (pA-nA) by moving the.
آشنایی با میکروسکوپ نیروی اتمی Dr. Janelle Gunther March 10, 1998 ACS Group and MENs, Beckman Institute adapted from the world wide web page at
Nano-technology and Nano-electronics
Scanning Tunneling Microscopy and Atomic Force Microscopy
ATOMIC FORCE MICROSCOPE Presented By Er. RANJAN CHAKRABORTY, B.Tech; A Student in M.Tech (VLSI & MICROELECTRONICS) 1 st Year, 2 nd Semester.
TAPPINGMODE™ IMAGING APPLICATIONS AND TECHNOLOGY
UIC Atomic Force Microscopy (AFM) Stephen Fahey Ph.D. Advisor: Professor Sivananthan October 16, 2009.
Tuning Fork Scanning Probe Microscopy Mesoscopic Group Meeting November 29, 2007.
FNI 1A1 Scanning Probe Microscopes SPM History of scanning probe microscopes SPM System Overview Piezoelectric Effect Scanning Tunneling Microscope (STM)
Cover of Scientific American, October Source: Actuator driven by thermal expansion of water and air.
NANO 225 Micro/Nanofabrication Characterization: Scanning Probe Microscopy 1.
Introduction to Atomic Force Microscopy
AFM. The cantilever holder The cantilever dimensions Tip position.
Tutorial 4 Derek Wright Wednesday, February 9 th, 2005.
Common scanning probe modes
Scanning Probe Microscopy Colin Folta Matt Hense ME381R 11/30/04.
Today –Homework #4 Due –Scanning Probe Microscopy, Optical Spectroscopy –11 am NanoLab Tour Tomorrow –Fill out project outline –Quiz #3 in regular classroom.
5 kV  = 0.5 nm Atomic resolution TEM image EBPG (Electron beam pattern generator) 100 kV  = 0.12 nm.
Atomic Force Microscopy (AFM)
Figure 3.1. Schematic showing all major components of an SPM. In this example, feedback is used to move the sensor vertically to maintain a constant signal.
Characterization of Nanomaterials…
Atomic Force Microscopy Alexander Chew Florida State University BSC5936 April 2005.
Fachgebiet 3D-Nanostrukturierung, Institut für Physik Contact: Office:
EEM. Nanotechnology and Nanoelectronics
Imaging Molecular Structures with Atomic Force Microscopy Tyler Flanagan, Unurbat Erdenemunkh Sponsor - (Professor Michael Boyer) Abstract As part of the.
Atomic Force Microscopy (AFM)
Scanning Probe Microscopy
METHODOLOGY Nanotechnology Prof. Dr. Abdul Majid Department of Physics
Pooria Gill PhD of Nanobiotechnology Assistant Professor at MAZUMS In The Name of Allah.
Get to the point!.
Get to the point!.
Molecular spectroscopy and reaction dynamics Group III
Scanning Probe Microscopy: Atomic Force Microscope
Probe Microscopes Designer: S.H.Kazemi IASBS University, Spring 2017.
Scanning Probe Microscopy
Scanning Probe Microscopy History
Scanning Probe Microscopy History
MODULE B-3: SCANNING TUNNELING MICROSCOPY
NANO 230 Micro/Nano characterization
Scanning Probe Microscope
INSPECTION TECHNIQUES
Scanning Probe Microscopy
Atomic Force Microscope
Atomic Force Microscopy
Presentation transcript:

Atomic Force Microscope (AFM) STM makes use of tunneling current It can only image conducting or semiconducting surfaces Binnig, Quate, and Gerber invented the Atomic Force Microscope in 1985 It can image almost any type of surface, including polymers, ceramics, composites, glass, and biological samples Calvin Quate (1923) Gerd Binnig (1947) Christoph Gerber (1942)

The first Atomic Force Microscope - Science Museum London

Main Components of an AFM Cantilever with a sharp tip Laser beam deflection system (introduced by Meyer and Amer) Detector and Feedback electronics Piezoelectric tube Image display system

How It Works Invented in 1986 Cantilever Tip Surface Laser Multi-segment photodetector Figure 4. Three common types of AFM tip. (a) normal tip (3 µm tall); (b) supertip; (c) Ultralever (also 3 µm tall). Electron micrographs by Jean-Paul Revel, Caltech. Tips from Park Scientific Instruments; supertip made by Jean-Paul Revel. http://stm2.nrl.navy.mil/how-afm/how-afm.html#imaging%20modes http://www.molec.com/what_is_afm.html

AFM cantilever (after use) in the SEM, magnification 1,000 x

                                                 The atoms of a Sodium Chloride crystal viewed with an Atomic Force Microscope

How does AFM work? Measure the forces between the sharp tip and sample surface Short-range forces Chemical forces: ionic bonds, covalent bonds, metallic bonds Repulsion forces: Pauli repulsion, ionic repulsion Long-range forces Van der Waals forces Capillary forces Magnetic forces Electrostatic force

How are forces measured? Hooke’s law: F= -ks Laser Beam Deflection Method

Fabrication of Cantilever Made from Si₃N₄ or Si As soft as possible to achieve high sensitivity Spring constant < equivalent spring constant between atoms of sample in order not to dragging the atoms out of its atomic site

Fabrication of Tip Made from Si₃N₄ or Si As sharp as possible The radius of curvature of the tip does not influence the height of a feature but the lateral resolution

Modes of Imaging Constant Height Cantilever is "dragged" across the surface of the sample Tip is free to move up and down Force between tip and sample surface is measured directly using the deflection of the cantilever No need to wait for the response of feedback system, scan in high speed No signal error x If surface is rough, can cause damage to tip and surface

Modes of Imaging Constant Force Move the cantilever up and down using the piezoelectric tube so that the position of laser beam is unchanged i.e. force between tip and sample surface remain constant Suited for almost every surface x Scan slowly, need to wait for the response of feedback system x Sensitive to random noise, has signal error

Constant Force Modes Contact Mode (<0.5nm tip-surface separation) Tapping Mode (0.5-2nm tip-surface separation) Non-contact Mode (0.1-10nm tip-surface separation)

Topography Contact Mode Non-Contact Mode Tapping Mode High resolution Damage to sample Can measure frictional forces Non-Contact Mode Lower resolution No damage to sample Tapping Mode Better resolution Minimal damage to sample 2.5 x 2.5 nm simultaneous topographic and friction image of highly oriented pyrolytic graphic (HOPG). The bumps represent the topographic atomic corrugation, while the coloring reflects the lateral forces on the tip. The scan direction was right to left http://stm2.nrl.navy.mil/how-afm/how-afm.html#imaging%20modes

Contact Mode Tip almost touches the surface Force on the tip is repulsive Force between the tip and the surface is kept constant during scanning by maintaining a constant deflection Advantages: Better resolution than tapping mode and non-contact mode Fast scanning Good for rough surface Disadvantages: x Force can damage or deform soft samples

Tapping Mode Cantilever is driven to oscillated up and down at its resonant frequency Probe slightly taps on the surface during scanning, contacting the surface at the bottom of its swing Adjust the height of cantilever by the piezoelectric tube to maintain a constant oscillation amplitude i.e. constant force between tip and surface is maintained Advantages: High resolution for the samples that are easily damaged (biological sample) Disadvantages: x Slower scanning speed needed

Non-contact Mode Tip does not contact the surface Similar to tapping mode, cantilever is oscillated at its resonant frequency Adjust height of cantilever to keep constant oscillation amplitude, constant force between tip and surface Advantages: Prevent tip from sticking to the surface (Note: all samples unless in a controlled UHV or environmental chamber have some liquid adsorbed on the surface). Low force exerted on surface No damage to tip and surface Disadvantages: x Lower resolution x Slower speed

Applications Biological Science : Live cell Human Lung Cancer Scan size: 60 µCell m

Applications Materials Science Polymer Science Data Storage : Help in design hard disk drive at nanoscale level Semi conductor DVD Surface topography of ZnO film Image of polymer blend

Lateral Force Microscopy The probe is scanned sideways. The degree of torsion of the cantilever is used as a relative measure of surface friction caused by the lateral force exerted on the probe. Identify transitions between different components in a polymer blend, in composites or other mixtures This mode can also be used to reveal fine structural details in the sample.

Lateral Force Microscopy Images/photo taken with NanoScope® SPM, courtesy Digital Instruments, Santa Barbara ,CA Natural rubber/ EDPM blend 20 micron scan Polished poly- crystalle silicon carbide film. Grain structures 30 micron scan Magnetic recording head Al oxide grains and contamination 800nm scan

Phase Imaging Accessible via TappingMode Oscillate the cantilever at its resonant frequency. The amplitude is used as a feedback signal. The phase lag is dependent on several things, including composition, adhesion, friction and viscoelastic properties. Identify two-phase structure of polymer blends Identify surface contaminants that are not seen in height images Less damaging to soft samples than lateral force microscopy

Phase Imaging Compositepolymer imbedded in a matrix 1 micron scan Image/photo taken with NanoScope® SPM, courtesy Digital Instruments, Santa Barbara ,CA Compositepolymer imbedded in a matrix 1 micron scan Bond pad on an integrated circuit Contamination 1.5 micron scan MoO3 crystallites on a MoS2 substrate 6 micron scan

Magnetic Force Microscopy Special probes are used for MFM. These are magnetically sensitized by sputter coating with a ferromagnetic material. The cantilever is oscillated near its resonant frequency (around 100 kHz). The tip is oscillated 10’s to 100’s of nm above the surface Gradients in the magnetic forces on the tip shift the resonant frequency of the cantilever . Monitoring this shift, or related changes in oscillation amplitude or phase, produces a magnetic force image. Many applications for data storage technology

Magnetic Force Microscopy Image/photo taken with NanoScope® SPM, courtesy Digital Instruments, Santa Barbara ,CA Overwritten tracks on a textured hard disk, 25 micron scan Domains in a 80 micron garnet film

Force Modulation Imaging Oscillate the cantilever vertically at a rate that is significantly faster than the scan rate. The amplitude of the oscillations changes in response to the sample stiffness. Used in conjunction with LiftMode to separate topography and elasticity data.

Force Modulation Imaging

Other Techniques Image/photo taken with NanoScope® SPM, courtesy Digital Instruments, Santa Barbara ,CA Scanning capacitance microscopy Apply a constant amplitude sine wave voltage to the sample. The image is then reconstructed from the changes in the amplitude of the capacitance oscillations. Location of defects in wafers (pinning of electrical carriers) Image carrier concentration Scanning thermal microscopy Uses a temperature sensitive probe with a special holder. Location of “hot-spot” defects in semiconductor wafers 90 micron scan size

Other Techniques Nanoindenting and scratching A diamond tip is mounted on a metal cantilever and scanned either with contact or TappingMode. Indenting mode presses the tip into the sample Scratch mode drags the tip across the sample at a specific rate and with a specified force. The use of TappingMode makes it possible to simultaneously image soft samples. Imaging of biological samples cells, DNA (TappingMode in solution)

Reference Wikipedia – Scanning Tunneling Microscope http://en.wikipedia.org/wiki/Scanning_tunneling_microscope Atomic Force Microscope http://en.wikipedia.org/wiki/Atomic_force_microscope http://ww.parkafm.com/ Atomic Force Microscopy lecture notes by HuiWen Cheng Introduction to Scanning Probe Microscopy (SPM), Basic Theory, Atomic Force Microscopy (AFM) by Robert A. Wilson and Heather A. Bullen, Department of Chemistry, Northern Kentucky University, Highland Heights, KY 41099.