NetTEST II PROFIBUS Analysis Tool

Slides:



Advertisements
Similar presentations
GG-Kennung oder Produktname Low voltage switchgear AS-interface Analyser AS-Interface.
Advertisements

Smart.IC II project Forklift truck connection Forklift truck connection, outside of the connector Automatic data download through GPRS and anlaysis of.
COMSOFT GmbH | NetTEST II | June 2009 | Page 1 Professional Test Tool for PROFIBUS DP Networks NetTEST II PROFIBUS Analysis and Test Tool.
Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
Basic Jens Neigaard.
easyEmission - 1st Steps & Overview
/// MELSEC Safety /// QS001CPU /// QS0J61BT12 /// QS0J65BTB2-12DT /// MELSEC Safety /// Mitsubishi Electric - MELSEC Safety - Training Documentation -
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
Advanced Workgroup System. Printer Admin Utility Monitors printers over IP networks Views Sharp and non-Sharp SNMP Devices Provided Standard with Sharp.
Active Stations PC PLC PROFIBUS Passive Stations (Field Devices)
Setup Guide - Profibus communication AC141x with Step 7 V5.5 English
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Graphical Alarm Management System
HiVision SNMP Software.
USART Communication using the RS standard ETEC6416.
Diagnostic & Troubleshooting Date 06/09/00, Page 1 Diagnostic & Troubleshooting s.
PROFIBUS wiring/installation can be done with:
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 2 Module 9 Basic Router Troubleshooting.
 COMSOFT GmbH | NetTEST II | July 2005 | Page 1 NetTEST II PROFIBUS Analysis Tool Professional Test Tool for PROFIBUS-DP-Networks.
Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between.
PLC ARCHITECTURE – Memory 2 by Dr. Amin Danial Asham.
CMV-NET Chigo VRF Network Centralized Control System
Cold-Chain Expert, Total Solution Quality Precision Service Value
Chapter 19: Network Management
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
Chapter 6 Input/Output Organization
Architectures of Digital Information Systems Part 1: Interrupts and DMA dr.ir. A.C. Verschueren Eindhoven University of Technology Section of Digital.
Chapter 13: I/O Systems Modified by Dr. Neerja Mhaskar for CS 3SH3.
Chapter Objectives In this chapter, you will learn:
Processes and threads.
Chapter 5.
Always Connected introduces Tigo SMART 3.0 This guide is interactive!
Now every configuration is possible
Certified PROFIBUS Engineer V4.1
Haiwell PLC Modules Introduce
Smart Ethernet I/O P2P and GCL Introduction
Direct Attached Storage and Introduction to SCSI
Chapter 11: Inter-Integrated Circuit (I2C) Interface
Chapter 2: System Structures
PROFIDrive PROFISafe.
How SCADA Systems Work?.
Quick help for fault location and reliable detection of defects
90-30 DeviceNet configuration
1 Input-Output Organization Computer Organization Computer Architectures Lab Peripheral Devices Input-Output Interface Asynchronous Data Transfer Modes.
Professional Test Tool for PROFIBUS DP Networks
EtherCAT® Configuration and Diagnosis Tool
Introduction With TimeCard users can tag SharePoint events with information that converts them into time sheets. This way they can report.
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Identifying SLC 500™ System Components
Siemens Step 7 Project with Controllere in 7 Steps: Step 1
Personal Computers and Applications
Direct Attached Storage and Introduction to SCSI
Programmable Logic Controllers (PLCs) An Overview.
HMI CP Range General Presentation.
Professional Test Tool for PROFIBUS DP Networks
Lecture Number 4 Siemens S7.
The simple system solution
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Voice Over Internet Protocol
Overview 1. Inside a PC 2. The Motherboard 3. RAM the 'brains' 4. ROM
Quick help for fault location and reliable detection of defects
AIMS Equipment & Automation monitoring solution
Integrated gateway-server
The Troubleshooting theory
Smart Prepayment Solutions for PV/SSEG
Chapter 13: I/O Systems.
DeviceNet Communication Solution for Discrete Devices
FIGURE 16–1 Module communications makes controlling multiple electrical devices and accessories easier by utilizing simple low-current switches to signal.
Presentation transcript:

NetTEST II PROFIBUS Analysis Tool Professional Test Tool for PROFIBUS-DP-Networks

NetTEST II – available in 3 versions NetTEST II Basis System for performing physical measurements NetTEST II with DP-Mono-Master function for DP-Slave configuration NetTEST II with Online-Function for the use with operational Profibus networks

NetTEST II – thoroughly checks your PROFIBUS DP-Network Costs 95% of all problems in PROFIBUS DP-Networks are caused by incorrect installations. Installation errors increase interference susceptibility enormously, whether it is a missing terminator or a broken shield. This results in sporadic non-reproducible errors, which can be caused for example by an increased EMC-load. Trouble shooting can cost days or even weeks. NetTEST II checks your PROFIBUS DP-Networks in detail and detects most typical installation problems. Find out for yourself that NetTEST II proves to be a powerful tool for eliminating PROFIBUS problems. Standstill of Delays Interruption Stop of delay

NetTEST II – a flexible system for mobile operation Graphical 128 x 64 Pixels LCD-Display with background illumination 6 x 4 - Keyboard Power supply via a rechargeable battery pack Battery capacity for approximately 4 hours of operation 9-pole SUB-D – gender changer for connection to PC and PROFIBUS Complete transport case with international battery charging set incl. power supply, additional battery, power supply adapter, Profibus-Configurator and various adapter cables for PC and PROFIBUS

NetTEST II – performs detailed measurements on physical level of the PROFIBUS line Determines the Impedance as well as the Cable Length of the connected PROFIBUS line

NetTEST II – discovers most of the typical installation problems Disruption of strand A, strand B and shield (with distance measured in m) Switched pairs of strands Short circuits (with distance measured in m) Branches (with distance measured in m) Inhomogeneous line segments (with distance measured in m) 390 220 5 V Correct terminating resistor (number and value) Non-powered terminating resistors 390 220

NetTEST II – contains helpful analysis functions for superior error detection Display of Live List of DP-Slaves Display of Ident-Numbers of DP-Slaves Signal Quality of DP-Slaves Baud Rate Detection und Signal Quality at Running Systems

NetTEST II – logs & archives your measurements Generation, display and storage of up to 20 test reports Management and archiving of the test reports via connected PC or notebook Communication from PC to NetTEST II via COM-interface und standard-terminal-software (e.g.Hyperterminal). No special software is required.

NetTEST II Measurement report ************************************************ Resulting protocol for PROFIBUS Network SW V2.20 05.11.01/21 Test company Name : COMSOFT GmbH Str. : Wachhaustr. 5a City : 76227 Karlsruhe Phone: 0721/9497-0 Mail : http/www.comsoft.de User name : Kurpat Customer Str. : Wachhausstr. 5a Mail : info@comsoft.de *********************************************** Unit : Area 1 Name: Segment 1 Own profibus address: 001 Number of 12Mbit/s-conns in seg. : 000 Number of profibus-devices in seg. : 002 Baud rate: 1.5 Mbaud Slot time: 001000 Date: 15/11/01 Time: 17:03:57 Analysation result for Test with no term. Analyzation result : No fault! ***************************************** Irregularity A<->B not detectable Irregularity B<->Shield not detectable Irregularity A<->Shield not detectable capacitive load junction or Impedance changes not detectable Broken line not detectable Cabling ok Impedance app 133 ohms Cable length 26m ********************************************************* Analysation result for Test with 1 term. **************************************** Correct termination Number of retries: 3 Analysation result for Test with 2 term. Number of retries: 1 Detected slaves in segment PB addr.: Level: Status: Ident.: [Name:] ------------------------------------------------- 042 8.0V Reflections 0x7510 055 8.0V Reflections 0x9510 -> XPS9510 Expected value for level measure : 2.5v<x<7.2v ****** Analysis of the tested PROFIBUS segment at one glance. All requirements of modern quality systems are met: Evidence of Functionality Archiving Traceability Reproducibility

Performing the measurement

A typical Profibus-DP-RS485 segment consists of: Strand A * Terminating resistor 1 * Strand B * Terminating resistor 2 * Shield * DP-Master and DP-Slaves * Drives Gateways Field Device Master 0 V +5 V 390 220 Terminating Resistor A B 0 V +5 V 390 220 Terminating Resistor Die PROFIBUS-Physik ist eine RS485-Zweidrahtleitung mit aktiven Abschlußwiderständen. Aktiv, d.h. die Abschlußwiderstände sind bestromt mit +5V gegen Masse. Die Versorgung erfolgt fast immer über den angeschlossenen Profibusteilnehmer also Master oder Slave. Die Impedanz oder Wellenwiderstand des Profibuskabels bträgt 150 Ohm, was Kabeltyp A entspricht. Kabeltyp B, welcher in der Norm EN50170 noch spezifiziert ist, hat einen Wellenwiderstand von 120 Ohm und andere Werte für die Abschlußwiderstände. Kabeltyp B ist veraltet sollte nicht mehr verwendet werden. Shield

Connection with the PROFIBUS NetTEST II is connected instead of the DP-Master at either one of the two bus ends Master 0 V +5 V 390 220 Terminating Resistor B Drives Gateways Field Device 0 V +5 V 390 220 Terminating Resistor Shield A DP-Slaves can be left connected to the bus in online mode

Performing a 3- stage test 1. without terminating resistors 2. with one terminating resistors 3. with both terminating resistors Drives 0 V +5 V 390 220 Terminating Resistor B A Gateways Field Device 0 V +5 V 390 220 Terminating Resistor Shield During the measurement procedure NetTEST II requests the user to switch on and off the respective terminating resistors

Simple & quick adaptation to the DP segment subject of measurement PROFIBUS address System Baud rate Slot time Number of 12 MBit plugs used Number of devices connected to the bus

Useful information for physical measurements The physical measurement of the PROFIBUS line is only carried out within electrical segments, without including repeaters. The minimum length of line to be measured is 10 m. The shorter the line lengths, the more inexactly the measurement may become. Only active stations (masters) have to be disconnected from the bus, slaves may stay connected. NetTEST II is designed for standard PROFIBUS-Cable type A (150 Ohm surge impedance, core cross section >0,34 mm²). Different types of cables, e.g. obsolete cable type B (100 Ohm surge impedance) are not to be used and are recognized as faulty by NetTEST II. Start

NetTEST II with DP-Master function for mobile setting into operation Setting into operation of DP-Slaves without time-consuming implementation of an SPS Configuration of DP-Slaves via comfortable PC tool on the basis of GSD file and integrated download function Comfortable access to the I/O-Data of DP-Slaves via freely definable tags Display and Coding of DP-Slave diagnostic data

NetTEST II – Trouble-free & comfortable The COMSOFT PROFIBUS-Configurator supplies NetTEST II with the DP-Slave configuration

NetTEST II – Multi-Talent as DP-Master Changing all DP-Slave parameters Execution of single PROFIBUS-DP services Simple DP-Slave start-up – not just for PROFIBUS experts Direct access to selective I/O-Data, e.g. digital outputs Start

NetTEST II with Online Function up to 12 Mbit/s – another highlight NetTEST II was enhanced by very powerful online measurement functions which even on the operative Profibus give detailed information about existing installation problems.

Measurements on the operative Bus Master Drives Gateways Field Devices

Measurements with PLC The following measurements can be conducted in online mode: Baud rate detection Generate live list Rotation time Signal level measurement Signal level summary list Event log Event count Diagnostic event

Baud rate detection During this Baud rate scan the overall signal quality at the Profibus is measured and a status is indicated.

Generating a Live List NetTEST II analyses the bus traffic and generates a Live List of all active and passive bus subscribers broken down by Masters and Slaves. Current Slave Live List Current Master Live List

Rotation Time NetTEST II determines the time the DP-Master needs in order to poll all configured DP-Slaves. The minimum and maximum values are stored and indicated. Rotation time is an explicit indicator for performance problems, e.g. in a sporadically disfunctional Profibus network

Level measurement NetTEST II measures the signal quality of each DP-Slave and visualises the value in a bar graph. Discrepancies of the measured signal levels from the allowed range point to specific errors of the Profibus network, e.g. signal levels above the allowed maximum are typical for reflexions in the profibus network.

Signal level sum list In the signal level sum list, the result of the signal level measurement is indicated in form of a table: ADD – Participant address COUNT – Number of measurements (excl. Time-outs) MIN – Minimum Values AV – Average Values MAX – Maximum Values

Event log NetTEST II analyses the data traffic between DP-Master and DP-Slaves and triggers upon communication status changes. The event log is represented in form of a table: ADD – DP-Slave address DATA OK – DP-Slave is in status of data exchange NR – No Response, DP-Slave is not responding TRY – DP-Slave responds only after multiple retries by DP Master CFG – DP-Slave was parameterised or configured DIA – Diagnostic messages pending at DP-Slave

Event count Should a singular DP-Slave show communication problems in the event protocol, it can be analysed in detail by the event counting. The event count shows the communication statistic for a single DP-Slave in detail. Also retries and communication errors are counted.

Diagnostic event The diagnostic event is an extended function of the event counting and serves the detailed analysis of an event. NetTEST II offers the choice between 6 events that may be triggered, e.g. diagnostic data or input/output data can be analysed. Should the selected event occur, all relevant data are displayed along with it.

Are you interested in more information ? Then contact our French Distributor : RESoluCOM SARL 17 rue des Genets 27190 LA CROISILLE Tel: +33 (0)2 32 37 85 75 Fax: +33 (0)2 72 68 58 20 E-Mail: info@resolucom.com Web: www.resolucom.com Start