GTR Rotor Andrew Cook Segment Manager March 7, 2011.

Slides:



Advertisements
Similar presentations
100% Outside Air and Dehumidification Management
Advertisements

HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Introduction Enthalpy Wheel
Elliott Microturbines Absorption Chiller Integrated System Development
Psychrometric Chart Basics
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
Engineer Presentation
COMMERCIAL REFRIGERATION
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Conditioning of Moist Air
Important variables Water: Air: Conversion:
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
The EWZ building Presentation of the building Presentation of the building The design issue The design issue The building concept The building concept.
Lecture Objectives: Finish with software intro HVAC Systems
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
HEATING AND COOLING SYSTEMS
Thermal Power Station.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Tank Heating by Various Methods for Metal Finishing and Other Process Heating Applications OVERVIEW 1.
Advanced Humidity Control. Energy Efficient Desiccant Based Dehumidification New class of desiccants that regenerate at lower temperatures Now able to.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
Johnson Controls1 Heat Pump Jean-Pierre Perron Sales Executive Johnson Controls,division YORK 0499/
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Gas Turbine Power Plant
Free Air Cooling for Data Centres
Air source heat pump Understand the fundamental principles and
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Elliott Microturbines Absorption Chiller Integrated System Development
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Natural Gas Production Chapter 5 Dehydration of Natural Gas
In-feed and Amine Sweetening 11/4/09
PHOTO GALLERY Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 7th edition by Yunus A. Çengel and Michael A. Boles.
BRAYTON CYCLE AND EFFECT OF INTERCOOLING , REHEAT AND REGENRATION
Notre Dame Power Plant.
BUILDING HEATING AND COOLING
Doug Jefferson, Business Development Engineer
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Desuperheater Water Heater, Heat Pipe Heat Exchangers, ECONET | Leading Manufacturer | Manor
Psychrometric Chart Basics. Basic Concepts Saturation Line.
New Options for DryCool Products
Munters DH Systems for Hospital Applications
Dry Kilns for Food.
Founder Munters AB Carl Munters (1899 – 1989) Swedish Inventor
Indoor Pool Design and Dehumidification
Munters DOAS, Chilled Beams and VRV
Energy Environment ENVE 411 Energy conversions.
Munters in Pharmaceutical Applications
Munters DOAS and Chilled Beams
Process Equipment Design and Heuristics – Heat Exchangers
April 6th, 2010 Munters DH Systems for Bulk Storage / Pneumatic Conveying Presented by: Andrew Cook Segment Manager.
Brian Wallingford, Applications Engineer
Chilled Beam Performance:
Cheryl Hughes Regional Sales Manager October 6, 2015
Munters DH Systems for Freezer Applications Presented by: Mike Sadosky
Humidity Control Applications Flakt Dryers
Roof Top Unit Overview (MAGNUM)
XXXXX Munters DH Systems for Spray Drying Applications Presented by: XXXX XXXXX.
Munters Heat Exchangers DOAS Review: Cost to Operate & Energy Analysis
Psychrometry & Air-conditioning
Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney
Energy Environment ENVE 411 Energy conversions.
Lecture 16 Aeration.
Announcements Exam 1 Next Class (Thursday, March 14th):
Regional Manager for Munters
Objective Revie the Cooling Cycle Learn about air distribution systems
Presentation transcript:

GTR Rotor Andrew Cook Segment Manager March 7, 2011

GTR Rotor What does GTR stand for: What is it’s composition: Gerry Trembly Rotor What is it’s composition: Combination SIGEL and Molecular Sieve Where can it be used: Coke Drying/Foundries Spray Dryers Fluid Bed Dryers and more…

GTR Rotor What are it’s advantages: What are it’s disadvantages: Better gr/lb depression with untreated outside air (high temp and moisture) Able to deal with higher reactivation inlet and outlet temperatures What are it’s disadvantages: Requires high temperature reactivation energy source: Direct Fired Gas High Pressure Steam (150 PSIG+) Because of the larger gr/lb depression, higher process outlet temperatures (advantage for some applications) Not selectable in the ICA software by reps. Need to have your applications engineer provide performance runs.

Flow Diagram Direct Fired Gas Heater Manual Balancing Damper DH React Fan D E F Process Fan 30% Filters (GTR3) C B A Balancing Damper

Spray Drying and Fluid Beds

Spray Drying and Fluid Bed Problems Production rate varies by season Drying time too long Inconsistent quality of the powder Production stops Product scrap Lack of flexibility Lots of customer use direct fired gas to heat ambient to 200-400°F

Typical Production Losses Related to Moisture

Munters Approach Using desiccant technology to dry the outside air required for the process (GTR) Provide a consistent low dew point (winter time conditions year round) Desiccant wheel removes moisture while also heating the process air (energy savings)

GTR Rotor Spray Dryer Applications Ambient 90°F / 130 gr/lb 140 120 Psychrometric Plot GTR Rotor Spray Dryer Applications Ambient 90°F / 130 gr/lb 100 80 Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) 60 40 20 -10 -10 10 20 30 40 50 60 70 90 150 200 350 Dry Bulb Temperature °F

Cool/Reheat Spray Dryer Applications Ambient 90°F / 130 gr/lb 140 120 Psychrometric Plot Cool/Reheat Spray Dryer Applications Ambient 90°F / 130 gr/lb 100 80 Humidity Ratio Grains of Moisture per Pound of Dry Air (gr/lb) 60 40 20 -10 -10 10 20 30 40 50 60 70 90 150 200 350 Dry Bulb Temperature °F

Reactivation Usage (summer): Process Savings (summer): Direct Fired Gas Heater Manual Balancing Damper HCE-15,000 React Fan D E F 30% Filters (GTR3) Process Fan C B A Balancing Damper Reactivation Usage (summer): Process Savings (summer): BTUH = ((6390) * (1.08) * (325-84)) / .92 BTUH = ((10,000) * (1.08) * (200-89)) / .92 BTHU = 1,807,800 btuh input BTUH = 1,303,043 btuh input Net Gas Used For Dehumidification = (1,807,800 – 1,303,043) = 504,757 Input Therefore (Net): 504,757 btuh / 713.8 lb water removed = 707 btu / lb water removed

Cooling Usage (summer): Process Fan B 30% Filters A C Balancing Damper Cooling Coil Direct Heater D Cooling Usage (summer): BTUH = ((10,000) * (4.5) * (42.76 – 11.22)) BTHU = 1,419,300 BTUH = 118 Tons Actual Gas Used For Re-Heat = ((10,000) * (1.08) * (200 – 30)) / .92 = 1,995,652 btuh Therefore: Gas Usage = 1,995,652 btuh Cooling Usage = 118 Tons (NOTE: Does not account for cooling inefficiencies (COP and defrost) for cooling below the freezing point of water) *NOTE: Higher gr/lb discharge because of the added moisture from the direct fired heater

Energy Comparison Dehumidification (84°F / 136 gr/lb) Cooling Only Net Net Gas Usage 504,757 BUTH 1,995,652 BTUH -1,490,895 BTUH Net Cooling Usage 118 Tons -118 Tons Additional Moisture from Burner 185.7 Added 185.7 Dehumidification (70°F / 90 gr/lb) Cooling Only Net Net Gas Usage 661,930 BUTH 1,455,652 BTUH -793,722 BTUH Net Cooling Usage 78 Tons -78 Tons Additional Moisture from Burner 127.5 Added 137.5

Energy Analysis (Cont.) For New Jersey: Target = 40°F DP, constant outlet gr/lb, 10,000 CFM of outside air $127,035 Cool / Reheat $76,081 Desiccant Dehumidification $50,954 Savings for DH vs. Cool/Reheat

Who is the Competition? Doing nothing. No humidity control means lack of quality control. Cool/reheat systems Require more energy Other desiccant dehumidification manufacturers Don’t have GTR

Who Should We Sell to? End users of the following industries: Dairy (powdered milk) Fragrance Companies Flavor Companies Gelatin Whey and other proteins Any powdered product that is spray dried (meats, fats, broth powders, etc.)

Europe's Customer Base Whey Lactalis 4 units Milk CPS Germany Celia (for baby) 2 units Sevres 1 unit Starch Roquette 6 units Yeast Lesaffre 5 units Kerry 1 unit Scotland Baby foods Kerry 3 units Malaysia Kerry Penang Food Colorant Roche Vitamines 1 unit Coffee Nestlé 3 units Soup Leibig 1 unit Aroma Aromes de Bretagne 1 unit Seaweed Sea Oil 1 unit Mix Bionov 1 unit

How Do Technical Details We Sell Simple Questions: Is your production better in the winter time than the summer time? If Yes, we can help. Would our operations be improved if we could create winter time conditions year round?

What Do We Need to Know What is the total CFM that you need for your process (making sure they include wall sweeps, etc.)? What do you have for reactivation energy? Understand your customers AHU requirements (construction, filtration, fan requirements).

Tools Show the customer that we can supply winter time condition year round Show the customer how much water you are preventing from entering the spray dryer or fluid bed

COKE What are we talking about? A Cupola or Cupola Furnace is a Melting Device used in foundries Diameters can be 18” – 13’ (round) Coke is a heat source used Coke is a high carbon coal. Air is fed through “Tuyeres” to the Coke Typically, raw outside air Metal is placed inside the furnace at the top The metal melts, has a chemical reaction with the COKE and other chemicals that may be added, and the liquid metal is removed at the bottom Electric Induction Furnaces are also used in foundries, they do not require dry air

Typical Cupola

Technical Details Lower gr/lb depression is achieved when lower face velocities are used Example, 10,000 CFM through a 15,000 wheel When looking at bin data, don’t concentrate on the highest gr/lb bin Production improvement will be the targeted sell point If energy is your story, make sure you work with your applications engineer on maximizing the performance

Coke For every lb of moisture that enters the blast, an additional 1.19 lbs of coke is required Coke is currently priced at $480.00 to $560.00/ton (can vary) The higher the outside air (ambient) moisture level, the more coke required to perform the same work

Munters Approach Using desiccant technology to dry the outside air required for the process (GTR) Provide a consistent low dew point Desiccant provides moisture removal required without cooling (industry does not want to deal with chillers or DX systems)

Cupola Dehumidification Process

Munters Installation at U.S. Foundry Miami, FL (2004) Direct Fired Gas Reactivation HCD-9000 SIGEL React Fan X Y Z C B A Process Fan 30% Return Air Filters

If We Did U.S. Foundry with GTR Additional 20 gr/lb depression Additional 115 lb/hr removed 33% more reactivation energy Direct Fired Gas Reactivation HCD-9000 GTR React Fan X Y Z C B A Process Fan 30% Return Air Filters

Installation D E F C B A Ship Loose Field Installation by Others Plate/Frame Heat Exchanger w/ Integral Cold Side Bypass 30% Filters React Fan D E F PowerPurge™ Option C B A Supply Fan 30% Filters

React Heat Exchanger With Internal Cold Side Bypass Hot Side A B C E F D G DH Reactivation Inlet Air Cross Flow Heat Exchanger Exhaust

Use the Resources Most of these plants have tower water that they are using in the process Can be used for post cooling to temperatures that the blast fans can use PowerPurge™ will help lower process outlet temperature A TW Cooling Coil Using 95°F water C B Plate/Frame Heat Exchanger w/ Integral Cold Side Bypass React Fan 30% Filters D Supply Fan PowerPurge™ Option E F

How We Do the Energy Analysis Select the bin data for closest city: Hours represent 10 hr/day operation per the parameters (total 2,860 hr/year)

How We Do the Energy Analysis Optimize the system based on first cost, savings and possible energy recovery options (use your Applications Engineer) Perform the runs for each bin and complete the analysis Summary

How We Do the Energy Analysis If we have the competitions performance, we can compare: Competition doesn’t know about using TW for post cooling (keep secret) Did not have, so assumed equal (with PowerPurge™, we should be less) The customer gave us Bry-Air’s performance We were provided their BHP

What Do We Need to Know: What is the total CFM that you need for your process? How should the Munters unit interface with their existing operation? What do you have for reactivation energy? What other utilities are available?

Industry Details Old Established Industry: They have been doing it this way for decades, why change now? First Cost Challenged Industry: They do not like to spend money Difficult to Establish Who are the Right People to Talk to Site Utility Manager Project Engineer Technical Director Engineering Manager Melt Superintendent

Customer Details Listen to your customer: Understand their concerns Work with them to use the different Munters technologies that we have: GTR Heat Exchangers Using Tower Water Keep it simple if it needs to be because of cost or other factors Help them find out if grant money is available!

Market Strategy Be first to the customer: This is actually not a new application (unit sold in 2004 was a replacement of HTS unit) We have seen Bry-Air in this industry http://www.thefreelibrary.com/_/print/printarticle.aspx?id=54577386 Understand our competitive advantage: Competition might not have the same gr/lb depression, but can try to make up for it on first cost Create specifications around Munters, and make the competition match

Tools Energy Analysis

What Do We Sell? Fully Welded Construction (discharge can be 200°F): HCD if CFM < 12,001 IDS if CFM > 12,001 or a complex system GTR Wheel Better gr/lb depression with raw outside air Basic Controls Reactivation control Face and bypass is outlet gr/lb level is critical (expensive sensor option, difficult control) High Temperature Reactivation Utility Direct Fired Gas High Pressure Steam (min 150 PSIG) High Reactivation Outlet (140 – 150°F)

Additional Opportunities Look for Possible Energy Recovery Opportunities: Possible reactivation outlet to process inlet Spray dryer exhaust for additional post heating Applications to look for Applications that can deal with higher process outlet temperature Applications looking for +/- 40 gr/lb and lower Open discussion

Thank you! 42