NVMe SSD Form Factor Challenges

Slides:



Advertisements
Similar presentations
Confidential Prepared by: System Sales PM Version: 1.0 Lean Design with Luxury Performance.
Advertisements

Cisco UCS Mini Martin Hegarty| Product Manager | Comstor
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
Improving Networks Worldwide. UNH InterOperability Lab Serial Advanced Technology Attachment (SATA) Use Cases.
Linux Clustering A way to supercomputing. What is Cluster? A group of individual computers bundled together using hardware and software in order to make.
Cisco and NetApp Confidential. Distributed under non-disclosure only. Name Date FlexPod Entry-level Solution FlexPod Value, Sized Right for Smaller Workloads.
Storage Networking Technologies and Virtualization Section 2 DAS and Introduction to SCSI1.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
UNH InterOperability Lab Serial Advanced Technology Attachment (SATA) Use Cases.
© 2014 IBM Corporation IBM FlashSystem John Clifton
© Hitachi Data Systems Corporation All rights reserved. 1 1 Det går pænt stærkt! Tony Franck Senior Solution Manager.
Make IT Simple, Make Business Agile ——Huawei IT New Products.
Mr C Johnston ICT Teacher BTEC IT Unit 02 - Lesson 02 Inside Computers #1 – Motherboards, CPUs, PSUs and Cooling.
1 An Introduction to the Storage Bridge Bay Specification.
Server Hardware Chapter 22 Release 22/10/2010Jetking Infotrain Ltd.
Copyright 2009 Fujitsu America, Inc. 0 Fujitsu PRIMERGY Servers “Next Generation HPC and Cloud Architecture” PRIMERGY CX1000 Tom Donnelly April
Chapter 5 Section 2 : Storage Networking Technologies and Virtualization.
Storage Systems Market Analysis Dec 04. Storage Market & Technologies.
FlashSystem family 2014 © 2014 IBM Corporation IBM® FlashSystem™ V840 Product Overview.
Surveon Enterprise Solution with Milestone Introduction Sales & Marketing Department.
STORAGE ARCHITECTURE/ MASTER): Where IP and FC Storage Fit in Your Enterprise Randy Kerns Senior Partner The Evaluator Group.
GPU Solutions Universal I/O Double-Sided Datacenter Optimized Twin Architecture SuperBlade ® Storage SuperBlade ® Configuration Training Francis Lam Blade.
Copyright © 2010 Hitachi Data Systems. All rights reserved. Confidential – NDA Strictly Required Hitachi Storage Solutions Hitachi HDD Directions HDD Actual.
This courseware is copyrighted © 2016 gtslearning. No part of this courseware or any training material supplied by gtslearning International Limited to.
PC COMPONENTS. System Unit Cases This is the cabinet that holds the main components of a computer. It includes a plastic front panel for aesthetic purpose.
Global Commercial Channels Sales Play Card Customer Challenge Windows Server 2012 feature PowerEdge 12G feature Customer Benefits “I’m unable to grow due.
Retail File 26 July 2016 Valid Until 29 July 2016 or Until Stock Last P/N HP SERVER TOWER ML310ev2 GEN8, 4U, INTEL XEON E3-1220v3, 4GB UDIMM.
EonStor DS series disk arrays
Extreme Scale Infrastructure
Journey to the HyperConverged Agile Infrastructure
E2800 Marco Deveronico All Flash or Hybrid system
EonStor DS 1000.
Managing HP Enterprise Virtual Array
Chapter 1: Introduction to the Personal Computer
EonStor DS 2000.
Flash Storage 2017 No notes.
SDM5A-M 7P/180D LP2(H).
Enterprise Computing Applications
Direct Attached Storage and Introduction to SCSI
What is Fibre Channel? What is Fibre Channel? Introduction
Windows Server* 2016 & Intel® Technologies
HPE Persistent Memory Microsoft Ignite 2017
Instructor Materials Chapter 1: Introduction to the Personal Computer
6 September 2017 OCP NIC subgroup teleconference
Unit 2 Computer Systems HND in Computing and Systems Development
Design Package Contribution for Project Olympus US1-EPYC
Direct Attached Storage and Introduction to SCSI
StorFly-IES Intelligent External Storage for Industrial-IoT ®
What’s in the Box?.
Power couple. Dell EMC servers powered by Intel® Xeon® processors and running Windows Server* 2016, ready to securely handle dynamic business workloads.
DESIGNED TO WORK BETTER TOGETHER.
Comments on OCP Mezz v3 & Connector/Pinout Proposal
ST
IBM® Storwize V3700 (Business Partner Version)
I/O BUSES.
The Greening of IT November 1, 2007.
TOSHIBA BG4 NVMe SSD Series
SERVER INNOVATION ACCELERATES IT TRANSFORMATION
Cost Effective Network Storage Solutions
Hard Drive Components 1.5 Install and configure storage devices and use appropriate media YT Video 3:30.
PCI Express® 4.0 and 5.0: The Future of NVMe™ Technology 2019 NVMe™ Annual Members Meeting and Developer Day March 19, 2019 Prepared by Justin Wenck,
Open Source Activity Showcase Computational Storage SNIA SwordfishTM
NVMe.
Midhet Dizdar IST Spring 2005
Microsoft Virtual Academy
OCP Engineering Workshop Rack & Power, Advanced Cooling Solutions, Data Center Facility
Factors Driving Enterprise NVMeTM Growth
Endurance Group Management: Host control of SSD Media Organization
BUNDLE Hewlett Packard SERVER DL 380 G10 WITH 32GB, 3x 1
Presentation transcript:

NVMe SSD Form Factor Challenges

Agenda A little bit of history Summary of potential NVMe SSD form factors System architectural challenges Server platforms Hyper-scale platforms Client platforms Presenters Bill Lynn Dell/EMC Michael Krause HPE Jonathan Hinkle Lenovo Chris Petersen Facebook

History HDD’s Form Factor Introduction Present SSD’s 1956 Refrigerator 3.75MB 1975 Washing Machine 92MB 1980 5.25” 5MB 1983 3.5” 10MB 12TB 1988 2.5” 20MB 4TB 1991 1.8” 21MB 250GB 1992 1.3” 20MB SSD’s 2009 mSATA 500GB 2013 M.2 1TB Refrigerator = IBM Model 350 (part of the IBM 305 RAMAC) , Washing Machine = DEC RP04 There have been a moderate number of HDD form factors but the industry settled on 3.5” and 2.5” The HDD form factor has been stable for the past 25 to 30 years Flash based SSDs for the most part have been around since 1995 using traditional HDD form factors New SSD form factors driven mainly by client applications (mSATA & M.2) 2.5” SSD go as high as 30TB and 3.5” as high as 60TB

HDD / SSD Architecture HDD Exploded View SSD Exploded View HDD architecture is complex and R&D costs are very high SSD architecture is relatively simple (if you are not counting the NAND and controller development) and R&D costs are low The falling cost of NAND and the low barrier to entry is giving rise to an explosion of SSD form factors SSD have the advantage of working in high G and weightless environments (no moving parts).

Potential NVMe SSD Form Factors SFF-TA-1008 SFF-TA-1007 NGSFF 2.5in U.2 This is what the customer sees (many different options) Ideally for enterprise you want one or two form factors that works in different platforms across the data center m.2 AIC

PCIe M.2 Applicable market segments Supported Connectors M.2 Benefits: Embedded / T&M, Client, Data center (e.g., SSD carrier) Connector and BGA solutions Supported Connectors x1 / x2: Mid-mount, single-sided, double-sided M.2 Benefits: Large, flexible mechanical form factor family Supports multiple protocols: PCIe/NVMe, SATA, USB, etc. Supports 14 vendor-defined pins to customize solutions Forward / backward compatibility Low power (3.3V & 1.8V using 4 power pins) Supports external connectivity: cables, antennae, etc. Multiple M.2 can be provisioned on a carrier form factor

U.2 2.5” SSD Applicable market segments Size Primarily data center with some enthusiast desktop Size 15 x 70 x100.45 mm up to 25W Supports SFF-8639 (PCIe x4) U.2 Benefits: Adds PCIe support to high-volume 2.5” HDD form factor Supports PCIe up to 16 GT/s High-capacity / high-density NVMe form factor Up to 24 modules in 2U enclosure Up to 14x18 mm packages per module Case for ESD protection and hot-plug support

SFF-TA-1006 Applicable market segments Size Data Center (optimized as scalable main storage and acceleration in server and storage systems) Size 31.5 mm x 111.5 mm x 5.75 or 7.55mm, supports up to 12W caseless Supports SFF-TA-1002 1C (PCIe x4) SFF-TA-1006 Benefits: PCIe to 32+ GT/s High-capacity / high-density NVMe form factor Up to 36 modules across 1U rack space Up to 12 14x18 mm packages per module 432 packages / U Supports integrated data-centric computation Case & Case-less Options

SFF-TA-1007 Applicable market segments Sizes Data Center (1U optimized server and storage enclosure) Sizes 9.5 x 38.4 x 318.75 mm supports up to 25W 18 x38.4 x 318.75 mm supports up to 40W Adds heat sink to improve cooling at system density expense Supports SFF-TA-1002 2C (PCIe x4-x8) SFF-TA-1007 Benefits: PCIe to 32 GT/s High-capacity / high-density NVM form factor 9.5 mm Up to 32 modules Up to 44 14x18 mm packages per module 1408 packages / U 18 mm Up to 18 modules 704 packages / U Supports data-centric computation Reduce packages to free up space for integrated accelerator Case for ESD protection, thermal management, & hot-plug

SFF-TA-1008 Applicable market segments Sizes Data Center (1U and 2U optimized server and storage enclosure) Sizes 7.5 x 76 x 104.9 mm supports up to 25W 7.5 x 76 x 142.2 mm supports up to 35W 16.8 x 76 x 104.9 mm supports up to 70W 16.8 x 76 x 142.2 mm supports up to 70W Supports SFF-TA-1002 1C, 2C, 4C (PCIe x4-x16) SFF-TA-1008 Benefits: PCIe to 32 GT/s, 802.3 to 112 GT/s High-capacity / high-density NVM form factor 7.5 mm Up to 48 modules 104.9 up to 24 14x18 mm packages per module (576 / U) 142.2 up to 48 14x18 mm packages per module (960 / U) 16.8 mm Up to 24 modules Up to 48 14x18 mm flash packages per module (960 / U) Supports data-centric computation Reduce packages to free up space for integrated accelerator Case for ESD protection and hot-plug support

Summary of Proposed Form Factors Width (mm) Length Thick Front Slots Power (Max) Pkgs (14x18) 2.5” (Baseline) 70 100.45 15 24 25 32 M.2 22 60/80/110 3.0 N/A 8.5 2/4/8 SFF-TA-1008* (Short) 76 104.9 7.5 48  20 SFF-TA-1008* (Long) 142.2 48 35 40 NGSFF* 30.5 110 4.3/4.8 72 16 12 SFF-TA-1006* 31.5 111.5 5.75/7.55 12** SFF-TA-1007* 38.4 318.75 9.5 64 44 *Newer form factors also support wide versions for higher capacity **12W TDP supportable for caseless version

Classical 2S Rack Server Architecture Drive Bays Expansion Typical rack server could be divided into thirds Front third typically for storage and supporting infrastructure Need to consider: Cooling Power Storage performance Memory performance Networking performance I/O capability Fans Server design is driven by workload and all about balance between Storage, Compute, and I/O Servers have to fit into racks (and they are not getting any larger, if anything they are getting smaller) Performance includes both bandwidth and IOPs Storage CPU & Memory Power & I/O

Server Design Considerations

Storage Subsystem Design Considerations Must balance drive size and host interface width with performance and capacity PCIe lanes available for NVMe storage in systems are going up, but drive performance is bounded by host interface Higher performance PCIe generations (PCIe 3.0 > PCIe 4.0 > PCIe 5.0) may allow drive interface widths to go down (x4 > x2 > x1) Scaling storage beyond host PCIe lanes drives significant cost by addition of PCIe switches and additional interconnect Fewer drives with higher capacity and x8 has no interconnect or switching cost benefits (i.e. 2 x4 = 1 x8) Higher performance, utilize more of the performance from flash in each drive Could be same capacity

Power and Thermal System Design Considerations Power delivery Drive power Overall system power budget Prefer lower current in system designs: higher voltage like +12V is useful Power density of drive vs. complexity and cost of thermal solution Drive pre-heat vs. keeping downstream system components cool Drive dimensions and drive spacing in system Airflow restriction through drives Exposed surface area of drive for heat transfer Lower voltage Higher current density Higher voltage Lower current density System Airflow drive spacing

How do hyper-scalers use flash today? M.2s

M.2 Carriers

Hyper-scale NVM Form Factor Characteristics Important: Flexible High volume Low cost Power and thermal efficiency Hot swappable Serviceable Less important: Backwards compatible Support for non-NVM media Maximum density Call to Action: Consolidate to a small number of form factors (<= 4)

Client Challenges Size, power, and cost are the biggest issues Many OEMs are planning on moving to NVMe on client platforms in the near future. Dependencies include: Cost Lowering the active idle power 2.5” x 7mm M.2 2280 M.2 2230 BGA

Cards beginning to adopt NVMe SD-PCIe SDA adding PCIe/NVMe interface to SD card (1) More content (4K/8K content, Social Media) More content generators (Drones, Action Cam, 360, VR CFA adding NVMe/PCIe (CFexpress) for high end photography Resolution (push to 8K RAW) Color Gamut – UltraHD Rec 2020 Higher Frame Rates (motion blur) Dynamic Range Use cases require existing NVMe/PCIe features and will create demand for new features (2) CFexpress (1) Currently under definition in SDA’s Spec WG (2) The microSD-PCIe card illustration is shown just for this presentation and it does not represent any official SDA standard, yet.