Lab Schedule.

Slides:



Advertisements
Similar presentations
Main Condensate & Feed Systems
Advertisements

Service Section Technical Training.
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
Department of Chemical Engineering, University of Michigan, Ann Arbor 1 6/10/2014 Troubleshooting Troubleshooting Guidelines 1.Gather information using.
Anion Performance Chemicals. Scale What is it? How is it costing you money? The Solution - Anion DScale Applications Key Features Major Customers.
REFRIGERATION Refrigeration may be defined as the process of removing heat from a substance under controlled conditions and reducing and maintaining the.
Daikin Altherma™ Troubling Shooting
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Refrigeration Flow Control
The First Law of Thermodynamics
Driving Toward Energy Efficiency Emerson Process Management Novaspect. Inc. June 22 / 23, 2010 Steam.
Steam Generation Efficiency
1 Acetone, 2-Propanol H 2 Acetone 2-Propanol L2 Acetone, 2-Propanol L201 L101L1 L3 L4 L10 L9 Condenser Reboiler Distillation Column Endothermic Reactor.
Evaporators For Air Conditioning
STEAM HEATING.
Hydraulics For The Long Term
1 HVACR316 - Piping Condensation Removal Refrigerant Traps Condensation Removal Refrigerant Traps.
HEAT EXCHANGER.
Principles of correct VRV Installation A. Refrigerant pipe work
Last Time Where did all these equations come from?
Heat Exchangers Heat exchangers are used to transfer heat from one stream to another. They are used to heat streams and to cool streams. The streams can.
Department of Chemical Engineering, University of Michigan, Ann Arbor 1 11/16/2015 Troubleshooting Troubleshooting Guidelines 1.Gather information using.
Thermal Control System. The Three Mechanisms of Heat Transfer Conduction - The transfer of heat through a solid –Interface Heat Exchangers –Cold plates.
Terry A. Ring Chemical Engineering University of Utah
Hilario J. Negrón (787) ext 3223 (787) Measuring Operational Efficiency.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
Dr. Owen Clarkin School of Mechanical & Manufacturing Engineering Summary of Energy Topics Chapter 1: Thermodynamics / Energy Introduction Chapter 2: Systems.
Air condition installation
James McIntyre VRF Training Manager V5 Key Components.
AIR CONDITIONING SYSTEM. FUNCTION Air conditioning systems create a safe and comfortable environment for passengers and crews in the aircraft cabin. The.
WSHP Systems 1.
Understanding the system.
First Law of Thermodynamics applied to Flow processes
Fixed Orifice Tube Cycling Clutch System (FOTCC)
1) What is the approximate percentage of oxygen in Earth’s modern day atmosphere? . Answer 21 %
GROUND SERVICING OF VARIOUS SUB SYSTEMS
Intake & Exhaust Components
Fluid Statics/Dynamics
GROUND SERVICING OF VARIOUS SUB SYSTEMS
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Chapter: 06 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES.
Heat Exchangers and Condensers
Thermodynamics Thermal Hydraulics.
Cryogenic behavior of the cryogenic system
air cycle cooling systems
Introduction to Food Engineering
HEAT EXCHANGER DESIGNPROJECT ME 414 Thermal Fluid System Design
The Second Law of Thermodynamics
The Basic Direct Expansion Refrigeration Cycle
Desuperheater Heat Transfer Device Manufactured by Maniks
Maniks Desuperheater for Refrigeration application
Why the Water Coming from your Car's Exhaust System.
Process Equipment Design and Heuristics – Heat Exchangers
PRODUCTS (POWER PLANT)
Flo-Direct®.
______________ Combustion Engine
Mathew C. Wright January 26, 2009
BELMONT RAPID INFUSER.
Brooke Conrad Du$tyyyyyyyy
Chapter 18 ChEN 4253 Terry A. Ring
R4 Troubleshooting Refrigeration
Defining the Problem Questions that Clarify: Why do you say that?
Solids Liquids Gases PHASES OF MATTER
Classification of air compressors. What are compressors? Compressors are mechanical devices that compresses gases. It is widely used in industries and.
Steam traps Applications and Recommendations
Specific Heat The amount of heat required to raise the temperature of 1g of a substance by one degree Celsius *The higher the specific heat, the slower.
Air Treatment School Refrigerated Dryer Training
12. Heat Exchangers Chemical engineering 170.
INTRODUCTION ALAQUA is a US corporation. We manufacture process equipment. Our engineers have over 20 years experience in the engineering of sanitary and.
Presentation transcript:

Lab Schedule

Terry A. Ring Chemical Engineering University of Utah Trouble Shooting Terry A. Ring Chemical Engineering University of Utah 1) The steam trap is blocked causing liquid condensate to back up in the heat exchanger so the steam does not contact the pipes in the exchanger. 2) The entering water is sub-cooled. 3) The steam pressure and temperature have dropped. 4) The heat exchanger has become fouled. 5) The steam is dirty, i.e., contains non condensable gases.

What is Trouble Shooting Problem solving process to find the root cause of a problem so it can be fixed. Trouble Shooting is not an exact science. Requires Paying attention to detail, good listening, understanding symptoms, viewing problem first hand

Try to Solve this problem QUESTION FROM TROUBLE ANSWER FROM EXPERTS COST TO ANSWER SHOOTERS Steam Pressure at PlOO? Higher Than Design. 5 min. Steam Temperature at TIOO? Design Value. 5 min. Amount of Condensate Drainable from Tubes Via the Bypass Valve? About 0.5 Pints of Condensate. 30 min. Feedwater Exit Temperature After 10 min. of Bleeding? 68 Degrees Celsius. 40 min (120 min. if Drain Valve Already Opened) Feedwater Exit Temperature After Bleeding Pipes? 3 Hours 45 Degrees Celsius. 3 Hours.   Bleed Gas Analysis Results. 20% Air. 2% Carbon Dioxide, Traces of Oil. 8 Hours. Action Cost Read meter 2 min. Check History 5 min Make Manual Measurement 30 min Adjust Operating Conditions 30 min Disassemble Equipment 4 hr Install new Equipment 5 day

Costs for Analysis Action Cost Read meter 2 min. Check History 5 min Make Manual Measurement 30 min Adjust Operating Conditions 30 min Disassemble Equipment 4 hr Install new Equipment 5 day

Guidelines

Critical Thinking and Trouble Shooting Kepner-Tregoe (K-T) Strategy Clearly determine what is the problem Classification of problem into Do we need to determine the cause of the problem Do we need to make a decision on the problem Do we need to plan to avoid future problems Develop multiple approaches simultaneously Establish probability for success (and cost) of each approach before proceeding Know what a potential response to a question will be under various problem scenarios.

Socratic Questioning Questions for Clarification Was the pump on when you heard the bang? Questions that probe assumptions Why did you assume that the white material in the pipe was calcium carbonate? Questions that probe reasons or evidence What is a past example that shows the same phenomenon? What is the reason you think that is true? Questions about viewpoint & perspective Where were you when you heard the bang? Where in the car is the squeak coming from? Questions that probe implications & consequences Did you see smoke before the compressor seized up? Questions about the question Why did you ask the question, was it raining when the compressor seized up?

Kepner-Tregoe (K-T) Strategy

When asking question or asking for analysis What will I learn if I ask this question? How will I use this information to find the fault? Keep 4 or 5 working hypotheses at any one time.

K-T Analysis

K-T Potential Problem Analysis Possible Cause Preventive Action Contingency Plan A. 1. 2. B.

Try to Solve this problem 1) The steam trap is blocked causing liquid condensate to back up in the heat exchanger so the steam does not contact the pipes in the exchanger. Heat transfer coefficient is less in this case. 2) The entering water is sub-cooled. 3) The steam pressure and temperature have dropped. 4) The heat exchanger has become fouled. 5) The steam is dirty, i.e., contains non condensable gases.

K-T Analysis

Possible Faults with Similar Behavior 1) The steam trap is blocked causing liquid condensate to back up in the heat exchanger so the steam does not contact the pipes in the exchanger. 2) The entering water is sub-cooled. 3) The steam pressure and temperature have dropped. 4) The heat exchanger has become fouled. 5) The steam is dirty, i.e., contains non condensable gases.