Design of Evacuation System for High-Rise Building Danqing Yu

Slides:



Advertisements
Similar presentations
Elevator System Control Devices and Applications
Advertisements

NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
The Application of Vertically-Mounted Jet Fans in Ventilation Shafts for a Rail Overbuild Richard Ray, Mark Gilbey and Praveen Kumar PB Americas, Inc.
Belfast Dublin Edinburgh London. Evacuation Modelling in Design Jeremy Gardner Jeremy Gardner Associates.
of NFPA 101 Life Safety Code Administration Definitions General
II. Dimensioning of a Branched Distribution System Main Procedures 1. Determination of the design water flowrates 2. Determination of the pipe diameters.
Emergency Evacuation Planning
Study on Foot Traffic Flows on Pedestrian Routes In Underground Traffic System 1 Moscow State University of Civil Engineering 2 Academy of State Fire Service.
Vehicle Flow.
Prevent False Alarms Eugene A. Cable, P.E., M.S.F.P.E. Life Safety Consultants NEHES Honorary Member 412 Horse Heaven Road Averill Park, New York
THE WASHINGTON MONUMENT (1884) The purpose of this study is to show how this structure supports its own weight and wind load, by calculating its efficiency.
1 Design of Evacuation System for High-Rise Building Danqing Yu.
VARIABILITY. PREVIEW PREVIEW Figure 4.1 the statistical mode for defining abnormal behavior. The distribution of behavior scores for the entire population.
FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.
International trends in codes and standards Affecting high speed lifts
Aerobus Safety & Security Proactive Measures to assure Aerobus passenger and system Safety & Security.
CONVEYING SYSTEMS INTRODUCTION PASSENGER ELEVATORS FREIGHT ELEVATORS
Means of Egress Chapter 4.
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Fire Safety By Alicia Civile and Alexandra Fernandez.
Lift Typical Building Floor Plan. Complete with fire walls. Click on and we will add Some of the different Passive and Active systems that you could come.
INTD 51 human environments building code. building codes deal with almost every area of building planning, design & construction they are very complex.
Picking up from last week…. Fire stair layout Fire stair layout Due October 18 th Due October 18 th Assignment #1.
Design Development Code analysis Partition types.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
Floor Wardens Safety Monitors & Guests. Overview.
BUILDING CODES AND ADA/TAS. BUILDING CODES - EGRESS.
Means of Egress Part 3 Chapter 4.
ID 234 Building Codes Fall 2012 Vertical Components of Egress.
Southeast Financial Center
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Chapter 4 ID 234 Building Codes Fall 2011 Means of Egress.
Considerations for making Product-Process Tradeoffs Product Appearance, offering, purchase price, etc. Process Procurement availability, ease of installation,
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
KEK, 04/28/061 Safety Plan Assumptions Break out of fire in the Beam Tunnel is negligible Cables in the Service Tunnel is main fire load They are combustible.
3M B&CSD - Fire Protection Space for 3M Montage © 3M All Rights Reserved. 3M Fire Barrier Duct Wrap 615 For Ventilation Ducts.
Incorporating Elevators and Escalators into Emergency Evacuation Models Richard W. Bukowski, P.E., FSFPE Senior Consultant Rolf Jensen and Associates Baltimore,
Using existing lifts in existing buildings to evacuate disabled persons Derek Smith Technical Director UK Lift and Escalator Industry Association.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Elevator Fire Service Mode Basic Operations Prepared by: Lt. Rob Fisher – L72C.
 The airborne solid and liquid particulates and gases evolved when a material undergoes pyrolysis or combustion. – NFPA 92A  Follows Path of Least Residence.
Southeast Financial Center
Code of Practice for Fire Safety in New and Existing Community Dwelling Houses Eamon O’ Boyle.
FIRE LIFT –DESIGN REQUIREMENTS in reference with NBC-2005
SUBJECT :. BUILDING CONSTRUCTION TOPICS:. PASSIVE FIRE PROTECTION. IN
Safety and Prevention of Typical Fire Plan
Science-Based Standards
EMERGENCY ESCAPE SLIDING CHUTE SYSTEM ( A Patented David Device )
Introduction The selection of the vertical transportation equipment is the most important decision to be made by the designer The passenger, freight elevators.
Q1. Name one function of a stairs?
FCC lifts Layout, characteristics etc.
GCSE Construction & The Built Environment
Wilson Hall Fire Protection Features
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Tenant Emergency Preparedness
Building and Fire Codes
CHAPTER 4 BUILDING TRANSPORTATION SYSTEM
GES SYSTEM THE IMPORTANCE OF GES SYSTEM IN BUILDING
The Wildland/Urban Interface
February 2019.
Interactive Source: Fire Statistics Great Britain,
Area of Refuge It’s the Law!
Head Office Emergency Evacuation Plan
Smokes extraction principle
Office Accidents H3SE integration kit TCNT 1.1 module.
Building standards Mr. Da Silva.
LIFT,ESCALATOR AND MOVING WALKS
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Presentation transcript:

Design of Evacuation System for High-Rise Building Danqing Yu 11/10/2018

Overview 30-years policy of US codes against use of elevators in fires ~ Attitudinal impediment Focus of current design: number, width and position of stairs ~ Is it adequate? Current use of elevator – Provide emergency use for firefighters and the disabilities Move large number of people from significant height ~ Call for safe and reliable elevator egress system Future trend ~ design elevators with emergency mode ( withstand heat, smoke, water, power-cut) 11/10/2018

Evacuation Plan for High-Rise Building Normal high-rise building Evacuation sequence: emergency floor – upper floors – lower floors Whether or not the elevators attend to disabled population first before they serve others Trained personnel to lead evacuation and good interface design ( switching driving mode for different emergencies) Mega high-rise building Elevators and refuge place are zoned vertically by sections Occupants are regularly trained for evacuation Express emergency shaft transit from refuge place to ground lobby in a non-stop fashion 11/10/2018

Buildings Types Need Emergency Elevators Residential Building Buildings with more than 100 persons per floor and with more than 50 floors Buildings with more than 200 persons per floor and with more than 20 floors Office Building Buildings with more than 50 floors and more than 50 persons per floor For 15-20 floor building, population per floor exceeds 100 11/10/2018

Parameters for Evacuation System Parameters of Building Evacuation Traffic Flow Building population No. of floors: f (1 f  F) Average passenger walking speed: (0.5~0.75m/s) Passenger density during emergency (1 person/0.46m2) Configuration for Evacuation System Proportion of population evacuated by stairs and elevators Width of evacuation doors (> 0.8m) Width and travel distance of stairs Positions of stairs and lobbies Size of the lobbies Emergency elevator configuration (number, safety mode, driving speed, group control logic ) 11/10/2018

Statistical Method Objective: Minimize total passenger evacuation time ~ Time between the beginning of evacuation and the time when the last passenger departs. Min Te, with Te= max (Tstairegress , Televatoregress) Evacuation by stairs Evacuation by elevators ~ Assume elevators are loaded by passengers from one floor Corresponding to different highest reversal floor 11/10/2018

Constraints associated with building traffic flow Space limitation Budget consideration Service quality requirement Normal mode Emergency mode Objective for configuring traffic system Minimize the weighted sum of average waiting time (or total service time) during normal mode and the evacuation time during emergency mode

Safety regulation Emergency mode for elevators Water tolerance parts, Emergency power if main power fails Enclosed lobby on each floor of the building, elevator should be installed in smoke-proof shaft  1 hour fire resistance and pressurized against smoke infiltration. Real time monitoring of elevator system status and any conditions that may threaten its safe operation. Max No. of elevators and stairs The number of floors in each elevator zone  15 ~ 16 floors Layout of elevators and stairs Typical building: 3000 m2 of floor space, 500 m2 core area (including elevator, 2 stairs: 1.2 m each) Stairs are located diagonally across the core area from each other. 11/10/2018