Study of bialkali antimonide photocathode on NB substrate at Jlab

Slides:



Advertisements
Similar presentations
Development of Bialkali Transfer Photocathodes for Large Area Micro- Channel Plate Based Photo Detectors 1 Argonne National Laboratory, Argonne, IL 2 University.
Advertisements

February 17-18, 2010 R&D ERL David Pate R&D ERL Photocathode Deposition and Transport System David Pate February 17-18, 2010 Photocathode Deposition and.
Visualizing Crystal Growth and Solid State Chemistry During the Recipe of bi-alkali photocathodes on Si(100) Miguel Ruiz-Osés Postdoc Stony Brook University.
Patricia Aguar Bartolomé Institut für Kernphysik, Universität Mainz PSTP 2013 Workshop, Charlottesville 11th September 2013.
Factors Affecting QE and Dark Current in Alkali Cathodes John Smedley Brookhaven National Laboratory.
K 2 CsSb Cathode Development John Smedley Triveni Rao Andrew Burrill BNL ERL needs – 50 mA, 7 mm dia., 1.3 mA/mm 2.
Laser etching of GaN Jonathan Winterstein Dr. Tim Sands, Advisor.
05/20/ High-Current Polarized Source Developments Evgeni Tsentalovich MIT.
GaAs and CsKSb Photocathodes for DC Gun
Quantum Dots. Optical and Photoelectrical properties of QD of III-V Compounds. Alexander Senichev Physics Faculty Department of Solid State Physics
Rong Xiang I I Photocathodes for Rossendorf SRF gun Rong Xiang for HZDR SRF-gun team 1 st Topical Workshop on laser based particle.
PEALD/CVD for Superconducting RF cavities
Metal photocathodes for NCRF electron guns Sonal Mistry Loughborough University Supervisor: Michael Cropper (Loughborough University) Industrial Supervisor:
Preparation of Clean III-V Semiconductor Surfaces for NEA Photocathodes Yun Sun 1, 2, Zhi Liu 3, Francisco Machuca 3, Piero Pianetta 1 and William E. Spicer.
ANL Photocathodes Growth and Characterization Facility Kathleen Broughton Charles Kurtz Ernesto Indacochea Alexander Paramonov Klaus Attenkofer Photocathodes.
Introduction Current and proposed linear colliders, energy recovery linacs and light sources require high quality electron sources. In particular, low-emittance.
Siddharth Karkare 1. OUTLINE Motivation and requirements Photocathode experimental facilities at Cornell Alkali-antimonide cathodes GaAs based photocathodes.
Operated by the Southeastern Universities Research Association for the U.S. Department Of Energy Thomas Jefferson National Accelerator Facility M. Poelker,
LAPPD Collaboration Review 12/9/2011 Ossy Siegmund, Sharon Jelinsky, Jason McPhate, Joe Tedesco Experimental Astrophysics Group, Space Sciences Laboratory,
Status of the Photocathode R&D for ATF RFgun N.Terunuma (KEK)
The CEBAF 200kV Inverted Gun P. Adderley, M. BastaniNejad, J. Clark, J. Grames, J. Hansknecht, J. McCarter, M. Poelker, M. Stutzman, R. Suleiman, K. Surles-Law.
Global Design Effort 1 Polarized electron source update Axel Brachmann, John Sheppard, Feng Zhou, Takashi Maruyama, -SLAC- Matt Poelker -Jlab- LCWS/ILC.
DC photogun vacuum characterization through photocathode lifetime studies Marcy L. Stutzman, Philip Adderley, Joseph Grames, Matthew Poelker, Ken Surles-Law.
Cs 2 Te Photocathodes for CTF3 Photoinjectors R. LOSITO - CERN 4/10/2006.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility Lifetime Measurements.
Non-conservation of the charge lifetime at high average current R.Barday University Mainz, Germany INFN Milano-LASA 4-6 October 2006.
Accelerator Science and Technology Centre Right: Schematic showing the setup utilised during activation to the NEA state in our test chamber.
Spectral Response of GaAs(Cs, NF 3 ) Photocathodes Teresa Esposito Mentors: I. Bazarov, L. Cultrera, S. Karkare August 10, 2012.
Quality-evaluation of Cesium Iodide photocathodes for the ALICE/High Momentum Particle Identification detector by means of a VUV-Scanner system Herbert.
Outgassing Test and the Getter Specification
Alkali-antimonide photocathodes using co-deposition and an effusion source Md Abdullah A. Mamun Carlos Hernandez-Garcia Matthew Poelker P3 Workshop : Photocathode.
Multialkali photocathode Luca Cultrera. Outline Motivations; State of the art; Alkali antimonides photocathodes; Growth UHV chamber; Load lock for photocathode.
COPPER PHOTOCATHODES DEVELOPMENTS AT ASTEC R. Valizadeh Accelerator Science and Technology Centre Science & Technology Facility Council, UK.
Operated by Jefferson Science Associates, LLC for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Polarized Electron Beams.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility M. Baylac,
Mg Films Grown by Pulsed Laser Deposition as Photocathodes: QE and surface adsorbates L. Cultrera INFN – National Laboratories of Frascati.
Paolo Michelato, Workshop on High QE Photocathodes, INFN-Milano LASA, 4 – 6 October Photocathodes: Present status and future perspectives Paolo Michelato.
Photocathode R&D for bERLinPro
An Electron source for PERLE
Jun Feng Advanced Light Source Lawrence Berkeley National Laboratory
JLEIC R&D weekly meeting, Thursday Jan 26, JLab.
MBE Growth of Graded Structures for Polarized Electron Emitters
Nathaniel Garceau, Wei Guo, Thomas Dodamead
Study of vacuum stability at cryogenic temperature
M. Hernandez-Flores1, M.A. Mamun2, and M. Poelker2
Cesium Telluride Photocathode Preparation at Argonne
Presenter: Zihao Ding Department of Materials Science & Engineering,
Polarized Gun R&D at Fermilab
Charlie Sinclair Cornell University (ret.)
Experimental Overview
Frontiers in Photocathode R&D
K2CsSb cathode tests at Jlab
Magnetized Bunched Electron Beam from DC High Voltage Photogun
Study of bialkali antimonide photocathode on NB substrate at Jlab
Thomas Jefferson National Accelerator Facility
Magnetized Electron Beam for Ion Cooling at JLEIC
UCB Bialkali Cathode Process Program
ELIC Injector Working Group High-P, high-I source issues (DC)
Production of Magnetized Electron Beam from a DC High Voltage Photogun
Bialkali Cathode Process Program
R. Suleiman and M. Poelker October 12, 2018
R. Suleiman and M. Poelker September 29, 2016
Status of Cathode System in FZR
Wei Liu Brookhaven National Laboratory
Characterisation of technical surfaces at cryogenic temperature under electron bombardment. Bernard HENRIST, CERN TE/VSC 5/6/2018.
Hydrogen and Ultra-High Vacuum
Shukui Zhang, Matt Poelker, Marcy Stutzman
DC Photocathode Gun (JLAB)
BNL Photocathode R&D An overview of research on high quantum efficiency photocathodes and associated laser systems Andrew Burrill HPHB Workshop Nov 9,
Development of “green” photocathode at INFN LASA Sandeep Kumar Mohanty, D. Sertore, P. Michelato, L. Monaco, G. Guerini Rocco, C. Pagani EWPAA 2019, Switzerland,
Presentation transcript:

Study of bialkali antimonide photocathode on NB substrate at Jlab Abdullah Mamun P3 Workshop : Photocathode Physics for Photoinjectors, October 17-19, 2016 Thomas Jefferson National Accelerator Facility, Newport News, Virginia, USA

Estimation of Spectral Response at 2 K for Bialkali Antimonide on Nb Substrate

Motivation The future Jefferson Lab Electron Ion Collider would require to implement electron cooling of the proton beam. A superconducting radio frequency (SRF) photogun is an ideal candidate electron source for this application, provided that the photocathode can give good yield or quantum efficiency (QE) at cryogenic temperature. The focus of this project is to make bialkali antimonide photocathode on a niobium substrate that can be used in an SRF photogun. The goal of this work is to estimate the spectral response at liquid helium temperature (2 K) by investigating the photocathode QE at different temperatures: Room temperature (295 K)  Water ice(273 K)  Dry ice (195 K)  Liquid nitrogen (77 K) temperatures.

Deposition chamber Photograph of the bialkali-antimonide photocathode deposition chamber with effusion-type alkali dispenser (shown in the inset), Schematic of the substrate holder assembly with substrate heater that acted as a cryostat, Photograph of the QE scanner system with the mirrors attached to the stepper-motor-controlled translation stages, Photograph of the GaAs substrate secured to the sample holder using an annular Ta cup, and Schematic of the effusion-type alkali dispenser used for coevaporation of K and Cs species (with permission from Lawrence S. Cardman). M.A. Mamun, C. Hernandez-Garcia, M. Poelker, and A.A. Elmustafa, “Effect of Sb thickness on the performance of bialkali-antimonide photocathodes,” Journal of Vacuum Science & Technology A 34 , 021509 (2016).

Bialkali Antimonide Photocathode by Codeposition Sources: Sb pellets (99.9999% purity, from Alfa Aesar) K ampoules (99.95% purity, 1 gram in argon) from Espi-metals Cs ampoules (99.9þ% purity, 1 gram in argon) from Strem Chemicals For the baked system, the evacuated chamber was baked at 180 C for 60 h Post bake vacuum reached ~1.410-9 Pa Sb evaporation via resistive heating by 32.7 A supply to the Tungsten heater Sb was deposited for ~30 min on Nb substrate at 200 C Alkali coevaporation was controlled by adjusting heater power and gas flow through the effusion source., in the following ranges: Inlet tube: 381-462 C Dispensing tube: 232-294 C Reservoir tube: 153-281 C Used a residual gas analyzer (RGA) to monitor the chemical’s vapor pressure during deposition. Representative partial pressures observed and maintained as: Sb PP: 7.3(±0.6)10-9 Pa; Cs PP: 1.8(±0.1)10-8 Pa K PP: 4.2(±0.5)10-9 Pa Alkali was deposited at substrate temperatures falling from 120 C to 80 C Alkali deposition continued as long as the photocurrent showed increasing trend QE was monitored using a 532 nm green laser with cathode biased at Vb= - 284 V M.A. Mamun, C. Hernandez-Garcia, M. Poelker, and A.A. Elmustafa, “Effect of Sb thickness on the performance of bialkali-antimonide photocathodes,” Journal of Vacuum Science & Technology A 34 , 021509 (2016).

Photocathode QE at Cryogenic Condition Photocathode QE is expected to decrease at lower temperature due to the change in the emission threshold (i.e., Eg+EA) of the semiconductor. The QE is also expected to decrease if chemicals adsorb onto the cold photocathode surface. These chemicals serve as contaminants that increase the surface work function. We investigated QE change as a function of temperature for two vacuum conditions of the deposition chamber (pre-bake and post-bake) and observed that: QE reduction due to contamination of the photocathode surface via adsorption can be minimized by reducing the amount of water vapor and oxygen within the gun chamber.

Vacuum Conditions We investigated QE change as a function of temperature for two vacuum conditions of the deposition chamber (pre-bake and post-bake) H2O

Distinguishing QE Drop due to Contamination QE Recovery RT LN2 RT (Post Heating) Brief heating 170 - 200 °C, H2O 34% H2O 26% Brief heating 170 - 200 °C, H2O 37% Pre bake vacuum ~1.810-8 Pa Systematic decrease in QE at RT in repeated cooling events Considerable increase in water partial pressure during brief heating was observed Rejuvenation of QE by brief heating at 170-200 C was consistently observed in the non-baked system which can be considered as a signature of water adsorption

Distinguishing QE Drop due to Contamination NO QE Recovery RT LN2 RT (Post Heating) Heating 170 - 200 °C, H2O 7.1% Post bake vacuum ~1.410-9 Pa NO Systematic decrease in QE at RT in repeated cooling events NO QE Rejuvenation from brief heating at 170-200 C in the baked system minimal water adsorption QE degradation due to photocathode lifetime in chamber

Reproducible QE in Cryocooled Photocathode RT LN2 RT (Post Heating) The QE at RT did not show any decrease between repeated cooling events QE at Liquid N2 temperature (77 K)showed similar QE every time it was cooled Initial QE rise due to stoichiometric optimization We did our spectral response and temperature analysis from this phocathode.

A shift in spectral response when cooled A shift equivalent to 35.6 nm in wavelength A change in emission threshold equivalent to a horizontal wavelength shift in spectral response when the photocathode is cooled to liquid N2 temperature (77 K)

Analysis Approach The experimental spectral response data were fitted according to R. H. Fowler, Phys. Rev. 38, 45 (1931): Correlate Vo and B with temperature and obtain temperature dependent functions Vo(T) and B(T) Evaluate Vo(2 K) and B(2 K), and use the values to simulate spectral response for photocathode at 2 K

Applying Fowler’s Model to the Experimental Data Allows to Estimate QE at 2 K Ice Water Vo 1.66 B -19.69 Vo 1.70 B -19.80 Vo 1.76 B -20.09 1.804 eV -21.246

Estimated QE Spectral Response at 2K λ Hν QE (%) nm eV 276.95 K 194.65 K 77 K 2 K (sim) 440 2.82 23.38 20.75 15.16 4.10 530 2.34 10.78 8.88 4.86 1.14 600 2.07 2.76 1.92 1.15 0.27 650 1.91 1.07 0.68 0.33 0.04 670 1.85 0.71 0.44 0.10 0.01

Conclusions A bialkali-antimonide photocathode (Cs and K)was grown on a niobium substrate. QE at LN2 temperature decreased as expected due to the change in the bandgap energy and electron affinity of the semiconductor. We used Fowler’s model to fit the experimental data and determined the temperature dependent Vo (T) and B (T) Fowler’s model and our experimental results extrapolate to an estimated QE for this cathode of ~1% at 2K and 530 nm, compatible with an SRF gun versus 10.8% QE at 277K.

Thank you Q&A

Backup Slides

Pre-bake

Post-bake

After ~70 days of activation of K2CsSb photocathode - QE did not recover with temperature reversal or rejuvenation effort by brief heating.