R. S. Davidson1; N. Faberowski2; R. J. Noecker3; M. Y. Kahook1 1

Slides:



Advertisements
Similar presentations
A Wireless, Implantable Intra- Ocular Pressure Sensor for the Management of Glaucoma Gabriel Simon, M.D. Ph.D. Sept 16, 2008 ESCRS.
Advertisements

Scanning Tonometer for Eye Pressure (STEP™) Problem Measurement of eye pressure by Goldmann applanation tonometry is a technique first embodied in the.
Transpalpebral Tonometry H.v.Below, O.Riemer Common practice for ambulant and stationary ophthalmology Grimma/Sachsen.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
1 Intraocular Pressure Spikes in Difluprednate Ophthalmic Emulsion 0.05% for Postoperative Cataract Inflammation by Melissa M. Cable, FAAO, FACS Discover.
Recent Advances in IOP measurements
Comparison between Dynamic contour tonometry, Goldmann applanation tonometry and Ehlers-corrected Goldmann applanation tonometry in eyes after Laser In.
SEI IOP and its correlations in a population based study in Central India. The Central India Eye and Medical Study. Krishna Bhojwani, Vinay Nangia, Jost.
Comparison of the Diaton Transpalpebral Tonometer Versus Goldmann Applanation R. S. Davidson 1 ; N. Faberowski 2 ; R. J. Noecker 3 ; M. Y. Kahook 1 1.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Purpose: Introduction:  At initial evaluation: For post-op day # 0 patients: Pre-op VA was 20/50.6 (0.395 ± 0.198); Post-op VA was 20/102.0 (0.196 ± 0.162);
EFFECT OF EYE COLOR ON SELECTIVE LASER TRABECULOPLASTY
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Glaucoma and Penetrating Keratoplasty : Incidence, Risk Factors, and Outcomes Sonika Gupta Consultant Ophthalmology Max Eye Care New Delhi, India Author.
Oliver Findl 1,2, Nino Hirnschall 1,2, Alja Crnej 2 1 VIROS Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria 2 Moorfields.
In-vitro measurement of Intra- Ocular Pressure Alex Luce Undergraduate Research Symposium 2008.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Changes of refractive error during pregnancy Aghadoost Dawood, Mesdaghinia Elaheh Kashan Medical Sciences University, Kashan Trauma Center, Kashan Iran.
Tonometry Objective measurement of IOP based, most commonly, on the forces required to flatten the cornea,or the degree of corneal indention produced.
Comparison of the Diaton Transpalpebral Tonometer Versus TonoPen- Applination Theodore H. Curtis, M.D.1, Douglas L Mackenzie, M.D.1, Robert J. Noecker.
1 Non-contact Specular Microscopy for Evaluation of Corneal Endothelium in Early Fuchs’ Endothelial Corneal Dystrophy Jianyan Huang 1, MD, PhD; Tudor Tepelus.
Naomi R. Goldberg, MD PhD Kenneth J. Wolf, MD Eric J. Wolf, MD FACS The authors have no financial interest in the subject matter of this poster. Comparison.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Visual and IOP Outcomes after PRK in Pigment Dispersion Syndrome [Poster Number: P190] Kraig S. Bower, Denise A. Sediq, Charles D. Coe, Keith Wroblewski,
Effect of Refractive State on Selective Laser Trabeculoplasty ASCRS 2011 Kevin Lai Stony Brook University School of Medicine Elaine M. Miglino Floral Park.
Date of download: 7/8/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Dynamic Contour Tonometry: A Comparative Study on.
V. Kumar 1,2, M. Frolov 1, I. Shepelova 1,2 Department of ophthalmology, People's friendship university of Russia, Moscow, Russian Federation 1 ; Ophthalmic.
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO.
iStent with phacoemulsification, n=50
CRF variations ( initial CRF – final CRF )
Suppressive effect of combined treatment of orthokeratology and 0
VERISYSE AND VERIFLEX PHAKIC IOLs FOR CORRECTION OF HIGH MYOPIA
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Safety of medication reduction for Primary Angle Closure (PAC) –
V. Kumar,1,2 M. Frolov,1 E. Bozhok,2 G. Dushina1
Purpose Results Results Methods Conclusion
Philadelphia Telemedicine Glaucoma Detection and Follow-up Study: Year 1 Results Lisa A. Hark, PhD, RD; Michael Waisbourd, MD; Kamran Rahmatnejad, MD;
A NEW INTRACANALICULAR DEVICE TO TREAT OPEN-ANGLE GLAUCOMA
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
Experience of application of “Tangent Screen Examination” inspection system and transpalpebral scleral tonometry at home (pilot study) A.P. Nesterov, E.A.
Blood Reflux In Schlemm’s Canal Of Normal Cataract Patients: Simple Way To Identify The Trabecular Meshwork With Healthy Collector Channel Masahiro Maeda1,
From: Effect of Hyaluronic Acid on Intraocular Pressure in Rats
Effect of Selective Laser Trabeculoplasty on
A presentation to: Meeting name Date
Copyright © 2013 American Medical Association. All rights reserved.
Date of download: 12/25/2017 Copyright © ASME. All rights reserved.
Enhancing accuracy of IOP estimation at the end of cataract surgery
Comparison of corneal powers obtained from four different devices
2/24/2013.
Keratometric Changes in Noninflammatory Corneal Ectasic Diseases After Intraocular Pressure Reduction Authors has no financial interest. Renata T Kashiwabuchi,
Associate Professor of Ophthalmology
Federal University of São Paulo, Brazil
Mai Pham MD, Sarosh Janjua MD, Jannet Ung MD, Sandra Cremers MD FACS
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Winthrop University Hospital
John C. Hwang, MD MBA Edward S. Harkness Eye Institute
Studený P., Siveková D., Vokrojová M., Farkaš A.
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
EFFECT OF CORNEAL THICKNESS ON SELECTIVE LASER TRABECULOPLASTY
Kristina E. Fittipaldi, BA
I-Chan Lin MD, Paul P. Lee MD, JD
ASCRS 2010 Joseph A. Donnelly Albert Einstein College of Medicine
Box and whiskers plot for bIOP, Goldmann applanation tonometry IOP (GAT) and Goldmann adjusted (GATAdj) in ocular hypertension (OHT), primary open-angle.
Presentation transcript:

Comparison of the Diaton Transpalpebral Tonometer Versus Goldmann Applanation R. S. Davidson1; N. Faberowski2; R. J. Noecker3; M. Y. Kahook1 1. Ophthalmology, Rocky Mountain Lions Eye Institute, Aurora, CO, USA. 2. Ophthalmology, Denver Health Medical Center, Denver, CO, USA. 3. Ophthalmology, UPMC, Pittsburgh, PA, USA.

Financial Disclosure The authors have no financial interest in the subject matter being presented

Background Diaton tonometry is a unique approach to measuring intraocular pressure (IOP) through the Eyelid. It is a non-contact (no contact with cornea), pen like, hand-held, portable tonometer. It requires no anesthesia or sterilization.

Purpose To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by transpalpebral tonometry using the Diaton tonometer versus Goldmann applanation in adult patients presenting for routine eye exams.

Methods Retrospective chart review of consecutive IOP measurements performed on 64 eyes of 32 patients age 34-91 years with both the Diaton tonometer and Goldmann applanation. Results between groups were examined using analysis of variance (ANOVA) where appropriate.

Results Mean IOP was 15.09 +/-4.31 mm Hg in the Goldmann group and 15.70 +/-4.33 mm Hg in the Diaton group (p=0.43). Mean IOP variation between groups was 1.74 +/-1.42 mm Hg (range 0-8). 83% of all measurements were within 2 mm Hg of each other.

Conclusions The transpalpebral method of measuring IOP with the Diaton tonometer correlates well with Goldmann applanation. Diaton applanation may be a clinically useful device for measuring IOP in routine eye exams.