Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Slides:



Advertisements
Similar presentations
Engine Tune-Up By Jonathan Rollins.
Advertisements

1. Instrument Clusters Theory Support Automotive – Displays & Accessories 1 of 13 Instrument Clusters Topics covered in this presentation: Analog Instrument.
MANUAL TRANSMISSION ELECTRICAL. OBJECTIVES n Diagnose electrical problems by logic and symptom description. n Perform troubleshooting procedures using.
RJ Mann Catalytic Monitoring Systems. RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure.
AC-SSC-1 Installation and operation manual
 Established in 1995  Located in Wilmington, NC with a 40,000 Sqft facility.  Specializes in the design and manufacturing of connection solutions. 
Stanley HP-1 Compact Power Unit.
Full Authority Digital Engine Control
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Fire Research Pump Boss 400 Pressure Governor
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
Oil PSI OIL Temp Fuel PSI Tach Water Temp Water PSI 14ga. 7 Wire Harness Key Ignition Start Starboard Engine 14ga Single Wire Fume Det Fume Detector Harness.
PORTABLE GENERATOR Dimensions: 25.88” x 21.13” x 24.75” Weight: 147 lbs. UPC: *AS RATED BY ENGINE MANUFACTURER MODEL: PM ©2007 POWERMATE.
Solar Charge Controller With Dump Load Circuit Built By Matt Smyrski.
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Diagnose the Starting System. Fender Covers ! You must have a strong battery to test the starter.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
Electrical Principles and Wiring Materials
Sales Training Outline 2006 Klaus Tum Product Manager Foot Switches 35 Royal Road Flemington, NJ
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
Electrical Principles and Wiring Materials
Table of Contents Electricity.
FG Wilson Access 4000 Control Panel
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
CHAPTER Wiring Schematics and Circuit Testing 9 Copyright © 2016 by Pearson Education, Inc. All Rights Reserved Automotive Electrical and Engine Performance,
PLS 2-10 TRANSMISSION SHIFT CONTROL 1. REVERSE 2. NEUTRAL 3. DRIVE 4. 3RD OR 4TH 5. DO NOT SHIFT 6. 1ST 7. 2ND.
1 Electrical Power Electronics Copyright © Texas Education Agency, All rights reserved.
Engine Maintenance Chapter 5 Inboard Diesel Engines Part 2.
I.C. ENGINES Practical No: 1 (17 Mar, 2014). Measurement of Cylinder Pressure If your vehicle has been running roughly or losing power, there may be a.
Engine Maintenance Chapter 8 Marine Engine Controls, Instruments and Alarms.
Electricity Currents, Circuits Electricity that moves… Current: The flow of electrons from one place to another. Current: The flow of electrons from.
Electricity.
Gauge Laser Pointer # Filed in December 2006 and Published in June 2008 Peter (Wonyoung) Kim OPT 310.
HETS 4-31 EXTENDED FOOTREST 1. LOCKPINS (2) 2. FORWARD LOCKPIN HOLES (2) 3. FOOTREST 4. SEAT 5. REAR LOCKPIN HOLES (2) 6. FLOORBOX.
Electro Eye-Hye System II
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
Physical Science Mr. Barry. Series circuits have one loop through which current can flow.
Static, Currents, Circuits
Concepts of Engineering and Technology Basic Electricity and Electronics: DC Circuits Copyright © Texas Education Agency, All rights reserved. 1.
Pressure Governor System Electronics. 2 Sentry Pressure Governor System Description The Sentry Pressure Governor System (SPGS) is a J1939 CAN based pressure.
Electricity. What is Electricity? a form of energy resulting from the existence of charged particles (such as electrons or protons) either static as an.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
Instrument Clusters Topics covered in this presentation:
Automotive Engines Theory and Servicing
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Introducing Current Electricity
Asahi/America Electric Actuators Series 94.
Understanding Olympian Generator Set Schematics
Easy Reach 7.0 Honda Element 2003
Easy Reach 7.0 Honda Element 2003
Electric Current Chapter 17.
Electric Current Chapter 34.
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Switches and Controls.
Copyright © 2018 W.S. Darley and Company. All Rights Reserved.
Fuel Supply System Chapter 21 Lesson 1.
NI Data Acquisition (DAQ) Wiring and Connections
Flotection: Building Main Shutoff System
Asahi/America Electric Actuators Series 94.
easYgen-3000XT Series Training
easYgen-3000XT Series Training
Compressor Operating Instructions
PRESSURE TRANSDUCER 250 PSI
Automotive Engines Theory and Servicing
Presentation transcript:

Copyright © 2018 W.S. Darley and Company. All Rights Reserved. DigiTrol™ Panel Kubota Mechanical Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1704 Main Panel Actuator Kubota Mechanical Engines (12VDC Battery) System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: High Engine Temperature (Default = Alarm/Shutdown) Low Oil Pressure (Default = Alarm/Shutdown) Over Speed (Default = Off) Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay) Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided C Series Display & Control MVP-M1104 Remote Panel Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON 70-0774-CAP Terminating Cap Page 1 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Copyright © 2018 W.S. Darley and Company. All Rights Reserved. DigiTrol™ Panel Kubota Mechanical Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1704 Main Panel Actuator Kubota Mechanical Engines (12VDC Battery) 70-0774-CAP Terminating Cap System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: High Engine Temperature (Default = Alarm/Shutdown) Low Oil Pressure (Default = Alarm/Shutdown) Over Speed (Default = Off) Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay) Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided SINGLE PANEL INSTALLATION C Series Display & Control Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON Page 2 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Diesel DOC/DPF Engines DigiTrol™ Panel Kubota J1939 DOC/DPF Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1716 Main Panel Kubota J1939 Diesel DOC/DPF Engines D180337T4-15040 (12VDC Battery) System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided C Series Display & Control MVP-A1116 Remote Panel Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON 70-0774-CAP Terminating Cap Page 3 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Diesel DOC/DPF Engines DigiTrol™ Panel Kubota J1939 DOC/DPF Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1716 Main Panel Kubota J1939 Diesel DOC/DPF Engines D180337T4-15040 (12VDC Battery) 70-0774-CAP Terminating Cap System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided SINGLE PANEL INSTALLATION C Series Display & Control Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON Page 4 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Diesel DOC Only Engines DigiTrol™ Panel Kubota J1939 DOC Only Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1717 Main Panel Kubota J1939 Diesel DOC Only Engines D1803TI49T4-15041 V2403TI65T4-15042 V3800TI74T4-15043 (12VDC Battery) System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided C Series Display & Control MVP-A1117 Remote Panel Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON 70-0774-CAP Terminating Cap Page 5 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Diesel DOC Only Engines DigiTrol™ Panel Kubota J1939 DOC Only Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1717 Main Panel Kubota J1939 Diesel DOC Only Engines D1803T9T4-15041 V2403TI65T4-15042 V3800TI74T4-15043 (12VDC Battery) 70-0774-CAP Terminating Cap System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided SINGLE PANEL INSTALLATION C Series Display & Control Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON Page 6 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Diesel DEF/SCR Engines DigiTrol™ Panel Kubota J1939 DEF/SCR Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1718 Main Panel Kubota J1939 Diesel DEF/SCR Engines D3800TI114T4-15044 (12VDC Battery) System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided C Series Display & Control MVP-M1118 Remote Panel Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON 70-0774-CAP Terminating Cap Page 7 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Diesel DEF/SCR Engines DigiTrol™ Panel Kubota J1939 DEF/SCR Diesel Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1718 Main Panel Kubota J1939 Diesel DEF/SCR Engines D3800TI114T4-15044 (12VDC Battery) 70-0774-CAP Terminating Cap System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided SINGLE PANEL INSTALLATION C Series Display & Control Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON Page 8 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Copyright © 2018 W.S. Darley and Company. All Rights Reserved. DigiTrol™ Panel Kubota J1939 Gas Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1719 Main Panel Kubota J1939 Gas Engines WG1605G-15045 WG2503G-15046 WG3800G-15047 (12VDC Battery) System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided C Series Display & Control MVP-M1119 Remote Panel Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON 70-0774-CAP Terminating Cap Page 9 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.

Copyright © 2018 W.S. Darley and Company. All Rights Reserved. DigiTrol™ Panel Kubota J1939 Gas Engines Pressure Transducer 0 to 500 psi 4-20mA MVP-M1719 Main Panel Kubota J1939 Gas Engines WG1605G-15045 WG2503G-15046 WG3800G-15047 (12VDC Battery) 70-0774-CAP Terminating Cap System Operation With system power ON: Push button engine start/stop from either station (10 second pre-heat period) Throttle increase/decrease from either station MVP Display/Controller (Metric/English Selectable) Engine Temperature ▪ Battery Voltage Engine Speed ▪ Fuel Level % Oil Pressure ▪ Engine Hours Engine Protections for: All Kubota J1939 ECU Alarms & Shutdowns Fuel Level (Default = Off) Alarm Log records alarms with engine hour stamp. MSG Pressure Gauge (Metric/English Selectable) Displays pressure (PSI/BAR) Low Pump Water Pressure Shutdown (shut down at 15 psi, 10 second start up delay Panel Materials Anodized aluminum plate (.09” thickness both panels) Panel Color (Gray metallic background with black lettering) Panel dimensions (8.5”H x 7.375”W) Panel dimensions (7.375”Hx 8.5”W) Metalphoto graphics and coating (for superior performance and scratch resistance) Mounting hardware not provided SINGLE PANEL INSTALLATION C Series Display & Control Notes: All components and connectors are water tight Modular panel system with custom extension harnesses available for plug and play installation and servicing 10 ft. and 20 ft. extension harnesses available Red OLED displays Momentary “push to start/push to stop” with over crank protection Green lamp for panel power indication (not engine run) 15 amp circuit breaker pre-installed for easy access 5 second glow plug sequence when panel is powered ON Page 10 of 10 Copyright © 2018 W.S. Darley and Company. All Rights Reserved.