Cheryl Hughes Regional Sales Manager October 6, 2015

Slides:



Advertisements
Similar presentations
Refrigeration & Air Conditioning
Advertisements

100% Outside Air and Dehumidification Management
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
100% Outside Air Systems for Light Commercial Applications ASHRAE Luncheon March 8, 2006 Outside Air Delivery Strategies Direct Reheat Reclaim (DX) Methods.
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Heating and Air Conditioning I
Introduction Enthalpy Wheel
ClimateMaster 2006 Rep Meeting ClimaDry™ Applications Jeff Hammond, Director of Marketing.
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015.
Best Direction System Ltd.
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
Evaporators For Air Conditioning
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Kurt M. Shank, M.S. & Stanley A. Mumma, Ph.D., P.E. College of Engineering Department.
Objectives Discuss Project Topics Learn to design VAV and DOAS System.
Conditioning of Moist Air
Introducing. The Comfort Zone (75° /50% RH) Every HVAC system is trying to hit this target. Hot, humid climates High latent load. The Challenge:
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
HEATING AND COOLING SYSTEMS
Principles of Solar Engineering D. Y. Goswami, F. Kreith, J. F. KreiderPrinciples of Solar Engineering Chapter 6: Solar Cooling and Dehumidification Part.
Achieving Dry Outside Air in an Energy-Efficient Manner PSU Building Thermal and Mechanical Systems Laboratory Environment A/E Stanley A. Mumma, Ph.D.,
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Lecture Objectives: Learn about processes in AHU Swimming pool example Het recovery systems.
ASHRAE Tech. Paper, Long Beach, CA. June 26,2007 Poster Session Presentation: Poster contents. Jae-Weon Jeong, PhD Assistant Professor. Texas A&M University-Kingsville.
Alexander Radkoff Mechanical Option | Spring 2014 Advisor: Dr. Stephen Treado 123 Alpha Drive Pittsburgh, Pennsylvania
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
Advanced Humidity Control. Energy Efficient Desiccant Based Dehumidification New class of desiccants that regenerate at lower temperatures Now able to.
A New (Rational) Way To Condition Air (and Save Energy) AEE, Philadelphia February 18 th 2016 Andrew Mongar, President, AirGreen LLC.
Technical Seminar on Application and Technical Specification June 2016
HCB 3-Chap 20B: Air- Water_Hybrid 1 Chapter 20 B: AIR-WATER AND HYBRID SYSTEMS Agami Reddy (July 2016) Description of traditional air-water system configurations.
SECTION 7 AIR CONDITIONING (COOLING) UNIT 35 COMFORT AND PSYCHROMETRICS.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Objectives Finish analysis of most common HVAC Systems
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Doug Jefferson, Business Development Engineer
Grunenwald Science and Technology Building
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
Psychrometric Processes
New Options for DryCool Products
Munters DH Systems for Hospital Applications
Virginia Product Overview
Indoor Pool Design and Dehumidification
Indoor Pool Design and Dehumidification
Munters DOAS, Chilled Beams and VRV
Energy Efficiency in District Coiling System
Munters DOAS and Chilled Beams
Brian Wallingford, Applications Engineer
Chilled Beam Performance:
Project.
Variable Frequency Drive (VFD)
Coleman Commercial Product
Engineering Presentation
HCB 3-Chap 19A: All-Air Systems_Single Zone
Presented by Scott McGinnis June 2012
Variable Refrigerant Volume
Munters Heat Exchangers DOAS Review: Cost to Operate & Energy Analysis
Psychrometry & Air-conditioning
Lecture Objectives: Discuss HW3 Learn about Heat recovery
Professor of Architectural Engineering College of Engineering
Objectives Finish with Heat exchangers
Announcements Exam 1 Next Class (Thursday, March 14th):
Objective Revie the Cooling Cycle Learn about air distribution systems
Keeping Doc’s Cool, Dry & Happy
Chapter 20 B: AIR-WATER AND HYBRID SYSTEMS
Presentation transcript:

Cheryl Hughes Regional Sales Manager October 6, 2015 Munters Heat Exchangers Brad Perdew Applications Engineer 8/27/12 DOAS Configurations Cheryl Hughes Regional Sales Manager October 6, 2015 cheryl.hughes@munters.com

Munters DOAS Configurations Presentation Purpose of Dedicated Outside Air Systems Review Building Loads Talking Dew Point is Critical How DOAS is Applied Munters Core Components Munters DOAS Configurations Munters Cost to Operate Spreadsheet

Purpose of DOAS ASHRAE recommends decoupling sensible and latent loads ASHRAE recommends lower delivered dew points Lower than the original “Neutral Air Unit” Lower than standard packaged DX or chilled water can deliver Outside air is good, but consumes a lot of energy to treat 90.1 wants to reduce energy LEED makes you prove you have reduced energy

Sensible Loads Have Reduced – Less Cooling Required, Less “Reheat” Available = Reduced Lighting Load = Reduced Solar Load = Improved Envelope

No Reduction in Moisture Load – Requires Active Dehumidification Outdoor Air People Infiltration Operations

Typical Buildings – Design Dew Points Space Served Dew Point Control Meeting Space Single 51-55°F Loose Grocery Store 48-52°F Medium Pharmaceuticals 49-56°F Tight Hotel/Condo Multiple 54-56°F Office 52-55°F Classrooms Healthcare Depends 42-52°F

Supply Air at the Correct Dew Point Chart accounts for internal latent load of occupants at 200 Btu/hr/person

& TOTAL ENERGY RECOVERY Multiple DOAS Options Different DOAS technologies Different system combos and methods of laying out DOAS Standard or custom solutions for every application Best EVAPORATIVE COOLING SENSIBLE ENERGY RECOVERY DEHUMIDIFICATION & TOTAL ENERGY RECOVERY EVAPORATIVE COOLING & SENSIBLE ENERGY RECOVERY

Munters Products Core Components Focus on Humidity Control Over-Cool & Reheat Wringer Cycle Cooling Coil Surrounded by Single Heat Exchanger Active Desiccant Reactivated by external source of heat Reactivated using “site recovered” energy Focus on Energy Recovery Wheels – Enthalpy or Sensible Heat pipes Plates – Counter-flow or Crossflow EPX – Polymer Tubes

Munters DOAS Products Without Exhaust Air Energy Recovery Cool-Reheat Wringer DryCool / HCU DDS (Config 1,2 & 5) HCD ICA With Exhaust Air Energy Recovery Sensible Heat Recovery Total Heat Recovery Sensible Wringer Plus Total Wringer Plus DryCoolERV DDS (Config 3 & 4)

Old Version of “Neutral” air to space 75°F at 55°F dewpoint = 50% rh 55°F 75°F DX Cooling Coil Hot Gas Reheat Compressors Supply Fan OA S/A

Now DOAS Should Deliver “Over Dried” Air to Space 75°F at 45°F dewpoint = 35% rh 45°F 75°F DX Cooling Coil Hot Gas Reheat Compressors Supply Fan OA S/A

Cool-Reheat (Brute Force) Cool air to desired leaving dew point and then reheat it to “Space Neutral” temperature Reheat must not be a "new" energy source per 90.1 Packaged DX unit (with Hot Gas Reheat) Highly competitive, Munters rarely sells Outside Air SA Cool Reheat

Over-Cool & Reheat (Common Selection) 60 ton CU 47.5F dp

Wringer Introduced by Des Champs in 1980 as a patented process surrounding a dehumidification coil with a single energy recovery device First pass across energy recovery device pre-cools humid air before coil . . . Reducing refrigeration requirements Second pass across energy recovery device reheats leaving air, reducing or eliminating the need for supplemental reheat Achievable dew point limited by coil temperature SA Sensible Heat Exchanger Outside Air Cool Reheat Rule of Thumb is 25% cooling load reduction.

Wringer 50 ton CU 46.4F dp Rule of Thumb is 25% cooling load reduction.

Exhaust Air Energy Recovery Pre-conditions OA with energy recovery device before cooling to desired dew point and then reheat it to space neutral temperature Energy Recovery Device SA EA CW Coil DX (AC/WC/WSHP) Reheat Outside Air Return/Exhaust Air Rule of thumb is 50% Summer tonnage reduction and 50% winter heat reduction.

Special WARNING About Energy Recovery System Performance! Critical Relationship

Exhaust Air Energy Recovery 50 ton CU 46.5F dp Rule of thumb is 50% Summer tonnage reduction and 50% winter heat reduction.

Wringer Plus Adds exhaust air energy recovery, sensible or total, to a Wringer SA EA Cool Enthalpy Wheel Heat Pipe, Plate or EPX Sensible Wheel Heat Pipe or Plate Reheat Outside Air Return/Exhaust Air Up to 65% summer tonnage reduction and 55% winter heating reduction.

Wringer Plus 30 ton CU 46.2F dp Up to 65% summer tonnage reduction and 55% winter heating reduction.

DryCool – Hybrid Cooling plus Active Desiccant DH Outside air first passes the pre-cool coil to < 60F saturated The pre-cooled air then passes thru the desiccant wheel to continue drying the air to ~45Fdp, the dehumidification process simultaneously raises the dry bulb temperature to ~75F Combining pre-cooling with active desiccant dehumidification reduces refrigeration requirements by ~40% Outside air for reactivation is heated by a condenser coil, the rest of the condenser heat is rejected to atmosphere Desicccant DH Wheel SA EA Cool Outside Air Outside Air Uo to 40% below the DX/Cond reheat option. Go to this when you want to be better than 90.1 baseline

DryCool Standard / HCU 40 tons precooling 43.6F dp

DryCool Chilled Water One 10 ton DX ckt 45.3F dp

DryCool ERV Adds exhaust air energy recovery to DryCool unit Suitable for indoor installations Desicccant DH Wheel Cool Outside Air Return/ Exhaust Air React Condenser Coil A Condenser Coil B Energy Recovery Wheel Outside Air

DryCool ERV 26 ton CU 43.7F dp

Enthalpy Wheel + Desiccant

Cost to Operate Comparison

Munters DOAS Presentation Recap Dedicated Outside Air Systems should be considered for all occupied spaces to provide adequate ventilation and meet codes Properly conditioning outside air takes a lot of energy, it makes sense to consider all ways to reduce operating costs Sizing and operating DOAS to maintain proper humidity control is crucial to occupant comfort and integrity of the building envelope Munters experience in humidity control plus Des Champs experience in energy recovery provide customers with a wide range of product options and expertise Each Munters system design has advantages and limitations to consider and can be compared side by side to aid in the decision making process

Questions