The simple answer to a serious problem

Slides:



Advertisements
Similar presentations
Generic Pressurized Water Reactor (PWR): Safety Systems Overview
Advertisements

Training Presentation
Circulating Water System
ADX 150 – Engine Repair ADX 170 – Climate Controls
Hydraulic Power Assist
Vermont Yankee Presentation to VSNAP 7/17/13 VY/Entergy Fukushima Response Update Bernard Buteau.
Simple Pressure Control Valves
POWER EQUIPMENT INSTRUCTOR: ROBERT A. MCLAUGHLIN ZAILI THEO ZHAO AUTOMATED CONTROL VALVES & PRESSURE REGULATORS W EEK :29 1.
Filling, purging and air removal
Issues Associated with the Development of Severe Accident Management Guidelines for CANDU Reactors Keith Dinnie Director, Risk Management Nuclear Safety.
Hydraulics.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Actuators.
STEAM HEATING.
Hydronic Mechanical Controls
SPD Cooling workshop: PLC item details. ups upgrade: 10-12' after trigger 24V - what to do in 10 minutes Present situation: In case of “normal power”
Hydraulics For The Long Term
Muhajir Ab. Rahim School of Mechatronic Engineering
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
HVAC523 Basic Subsystems.
Pneumatic system. It is important to know that we are working with compressed air and not with a fluid like at hydraulic systems. Pneumatics is when compressed.
Nuclear Thermal Hydraulic System Experiment
3.4.3 Student Book © 2004 Propane Education & Research CouncilPage Bulk Plant Emergency Shutdown Equipment and Periodic Examination Methods One.
FLEX SUPPORT GUIDELINE TO ISOLATE THE SI ACCUMULATORS
HYDRAULICS & PNEUMATICS
Risk-informed On-Line Maintenance at Cofrentes NPP IAEA Training Course on Safety Assessment of NPPs to Assist Decision Making Workshop Information IAEA.
NITROGEN A CLOSED ITEM ? AN STUDY ABOUT THE THREAT OF THE NITROGEN INJECTION TO RCS, AND THE STRATEGIES TO COPE WITH THIS ISSUE IN OUR NUCLEAR PLANTS.
I & C.
Heat Engines A gasoline engine is a form of a heat engine, e.g. a 4-stroke engine INTAKE stroke: the piston descends from the top to the bottom of the.
1 3E-03 Fire Syringe RAPID COMPRESSION IS ADIABATIC GIVING RAPID RISE OF AIR TEMPERATURE IN THE CHAMBER WHICH EXCEEDS THE IGNITION TEMPERATURE OF THE FLAMMABLE.
Adca Training Part 4 This presentation is only a guideline, that can only be completed by a trained personel. Adca Steam Equipment Training.10.
Unit Twelve Pilot Operated Pressure Control Valves At first glance the diagram would appear to show three different valves but the box surrounding the.
VALVES IN PIPE LINES.
GROUND SERVICING OF VARIOUS SUB SYSTEMS
2016/12/6 Yasuhiro R&D status of a gas-compressor based 2-phase CO2 cooling system for FPCCD vertex detector 2016/12/6 Yasuhiro Sugimoto.
Unit III Class I Pneumatics.
HYDRAULIC & PNEUMATIC CIRCUITS
INDUSTRIAL PNEUMATICS
GROUND SERVICING OF VARIOUS SUB SYSTEMS
- Condensate pump and feed pump trip!
The simple answer to a serious problem
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
14 Refrigerant Recovery, Recycling, and Recharging.
PRESSURE CONTROL VALVES (PCVs)
Mechanical Aspiration
Steering Systems Topics covered in this presentation:
Thermodynamics Processes.
A PROPOSAL TO TRANSPORT FLUIDS FROM WELLHEAD TO FLOW STATION USING A GAS DISPLACEMENT PUMP. Juan Carlos Brown, 6th July 2017.
OBJECTIVES State the principles of vacuum and the vacuum booster theory. Discuss how a vacuum brake booster operates. Discuss the vacuum booster operation.
ANTI LOCK BRAKING SYSTEM
Steam Power Generation
Tracker cooling loop “check out” draft for discussion
© Copyright, HQT-SV Control System
DELTAK HEAT RECOVERY STEAM GENERATOR
Valves.
Welcome to Malaga WeBex سیستم سوخت رسانی ریل مشترک کاتر پیلار
Diesel Automotive Engines
Diversity analysis for advanced reactor design
Hydraulic Pressure Control
NRC Event Number – Event Date
Session Name: Lessons Learned from Mega Projects
Instrumentation and control
- Condensate pump and feed pump trip!
Group 1 Best Group.
Lockout/tagout Refresher Training
The simple answer to a serious problem
THE ROLE OF PASSIVE SYSTEMS IN ENHANCING SAFETY AND PREVENTING ACCIDENTS IN ADVANCED REACTORS Moustafa Aziz Nuclear and Radiological Regulatory Authority.
Mikael Olsson Control Engineer
Nuclear power plant System Cost Safety
Presentation transcript:

The simple answer to a serious problem My First Template The simple answer to a serious problem International Conference on Topical Issues in Nuclear Installation Safety: Safety Demonstration of Advanced Water Cooled Nuclear Power Plants. Vienna. 6 – 9 June 2017 The Nitrogen Threat Why nitrogen is a risky threat to our reactors? Current strategies to deal with it. The new Valve ASVAD. Advantages. Conclusion & questions. by Arnaldo Laborda www.asvad-nuclear.com 1

TO MAKE OUR NUCLEAR PLANTS SAFER My First Template The Main objective TO MAKE OUR NUCLEAR PLANTS SAFER Revealing the inner enemy that can lead us to disaster, stabbing our cooling systems directly from its inside Introducing ASVAD, the new valve that will protect us from the nitrogen injection threat 2

My First Template The Reason Some studies were done in the past about the gas effects in the ECCS systems. The amount of gas considered were limited to small quantities. After the NRC GL-2008-1, plants evaluated its potential affectation, also considering small quantities of gas. After Fukushima, plants developed actions to avoid the nitrogen injection from the accumulators, mainly based in FLEX equipment. Neither plants nor regulators took further actions after that. It seems a “CLOSED ITEM”. In this presentation, we will discuss this issue, because it seems underestimated. Is there a big (and hidden) enemy inside our plants? 3

Natural accident progression 1 A hard Fukushima lesson: One of the worst nuclear accidents is the ELAP (Extended Loss of AC Power) accident, also known as LTSBO (Long Term Station Black-Out). In this accident, all the electrical energy is lost during long time. The plant control is fully lost. This accident also leads us to other serious accident: the LOCA (Loss Of Coolant Accident). It will jeopardize the core cooling. CORE MELTING ELAP LOCA Natural accident progression 4

ELAP: The accident worsens (45h - 60h) THE NEW PROBLEM: THE NITROGEN INJECTION Nitrogen reaches the top of SG’s tubes. Natural circulation is stopped. The reflux cooling mode begins… but is also disturbed by the nitrogen. M Water CST The nitrogen reaches the reactor displacing the water… Nitrogen will remain inside RCS disturbing the long term cooling and threatening the core integrity Without enough steam, the AFW turbine stops. When the water ends, nitrogen gets into the RCS NATURAL CIRCULATION REFLUX COOLING If FLEX Equipment can’t maintain the RCS pressure then… The RCP seals continue leaking. 5

> NITROGEN: How BIG is the problem? P * V = n * R * T 585 m3 340 m3 Each accumulator has 14 m3 (~650 Kg) of nitrogen (@ 45 Bar @ 35ºC). This nitrogen follows the ideal gas laws. During the accident, the gas temperature will rise. And LOCA will depressurize RCS. This means the nitrogen will expand. It can reach 585 m3 (@ 1 Bar @ 35ºC). The total RCS volume is around 340 m3 (@ 4 loop plants). Just one accumulator has enough nitrogen to fill the whole RCS volume. And there is one accumulator in each loop. P * V = n * R * T > M 585 m3 340 m3 14 m3 M Then, the problem IS THREE OR FOUR TIMES BIGGER !!! 6

2 Current strategies Close the outlet isolation valves Closing the valves one by one using a FLEX AC generator. Time critical action. But even closed, the valves can leak nitrogen to RCS during all the time. All are active elements. Open the nitrogen relief valves Using a FLEX air compressor to open these valves. The air distribution has to be operable, but it is not designed to withstand accidents. Time critical action. Alternative strategy. Keeping high the RCS pressure While the RCS pressure is higher than the nitrogen pressure, there is no injection. A Flex pump is needed. Just to get time trying to close the valves. Temporary strategy. 8

Do you still rely on it ? Current strategies weakness SUCCESS ? Current strategies rely on: TIME CRITICAL ACTIONS Knowing the correct moment to perform it. Having enough time to perform it. The deployment of some ACTIVE elements and its proper actuation. The Flex AC Power Generator availability. The cabling deployment to the valves. The valve’s ability to isolate the accumulators. The proper organization actuation. Their capabilities to perform the work. The adequate operator’s training. ACTIVE ELEMENTS ORGANIZATION EFFORTS SUCCESS ? This is a long chain of active elements! Just one failure, it means nitrogen injection. Do you still rely on it ? 9

3 A S V A D The ASVAD safety valve The SIMPLE SOLUTION to the nitrogen injection problem. A S V A D AUTOMATIC SAFETY VALVE FOR ACUMULATOR DEPRESSURIZATION 10

How ASVAD is installed? RCS M NITROGEN BORATED WATER EXAUST ASVAD It only needs a manual isolation valve and few feet of pipe. ASVAD Is installed in the nitrogen side of the accumulator. 11

What is inside ASVAD? Pressure chamber. Upper container. Locking cylinder. Closing piston. Fixing cylinder. Shut-off plug. Opening spring. Spring container. Fixing screws. Opening piston. Upper cover. 12

How ASVAD works? The ASVAD operating principle is the imbalance of forces: The force done by the accumulator pressure against the spring force. During the injection, the nitrogen expands, and its pressure drops. When the pressure is low enough, the spring overcomes the pressure force. Then, the shut-off plug are suddenly displaced to the bottom. This provides an open path to exhaust all the residual nitrogen in the accumulator. 13

Manual operation mode ASVAD can be opened, applying pressurized air to the “open” inlet. This pushes the opening piston downwards, until the plug opens. ASVAD can be closed, applying air to the “close” inlet. The air pressure pushes the closing piston upwards, closing the shut-off plug. Now, the accumulator can be refilled again. When the air is exhausted, the piston returns to their initial position, and ASVAD remains armed. 14

Main advantages of ASVAD It is ALL TIME AVAILABLE from the first moment. It FULLY AVOIDS the nitrogen injection problem. NO EXTERNAL ENERGY is needed. NO OPERATOR assistance is required. It acts at the CORRECT MOMENT and over ALL the accumulators. It acts AUTOMATICALLY sensing the accumulator pressure. Once it actuates, it vents COMPLETELY the accumulator. No further nitrogen injections are possible. Its action CAN BE VERIFIED by the available instruments. It will SAVE ORGANIZATION EFFORTS, allowing to focus on other recovering tasks. 15

More advantages of ASVAD HIGH RELIABILITY due its robust and simple design. HARD ENOUGH to bear the post-Loca environment. EASY TO BE INSTALLED in the accumulator system. EASY TO BE LICENSED. Does not add a new failure mode. INTRINSICALLY SAFE. No EMC. No software. Cyber-attack proof. QUALIFIED for nuclear use. It’s a nuclear class 2 valve. EASY TO BE OPERATED. It can be remotely actuated if needed. EASY TO BE MAINTAINED. No wear in the valve. Few spares needed. With minimal maintenance cost. EASY TO BE TESTED. It can be functional and leak tested. EASY TO BE ADJUSTED to the desired pressure actuation. CHEAP. No expensive modification is needed. HIGH QUALIFIED LIFE. No further investments required. 16

The Nitrogen Threat (TNT) 4 The Nitrogen Threat (TNT) ¨ ASVAD M Current strategies Simple N2 Auto Active Components Organization efforts Passive Safe FLEX Procedure Nitrogen is like a missile that goes right to our RCS “veins” Now, we only have weak strategies to avoid its effects. This is like a giant with feet of clay… Fortunately, now we could install ASVAD… the best passive defense. 18

Conclusion The nitrogen injection to RCS is a REAL THREAT to the core integrity, and the current strategies to avoid it are TOO WEAK to rely on them. Applying the Defense in Depth concept, ASVAD is the FIRST and the STRONGEST SAFETY BARRIER to avoid the nitrogen injection. It will be available all the time, protecting our RCS from nitrogen. Nuclear community HAVE TO REEVALUATE this issue. It’s OUR RESPONSIBILITY to definitely solve this threat taking actions. Nitrogen IS NOT a closed item. 19

Questions Now is your time to ask… (or to act) www.asvad-nuclear.com My First Template Questions Now is your time to ask… (or to act) More information at: info@asvad-nuclear.com or www.asvad-nuclear.com 21

Thanks ! 22