On behalf of the GECAM group

Slides:



Advertisements
Similar presentations
Performance Evaluation of SiPM Arrays under Strong Magnetic Fields
Advertisements

Nustar/crystal simulations B. Genolini Crystal: CsI(Tl) (Saint Gobain), wrapped with reflector (VM2000, Tyveck?) Geometry:
Crystals and related topics J. Gerl, GSI NUSTAR Calorimeter Working Group Meeting June 17, 2005 Valencia.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Shu Zhang (on behalf of the HXMT team) Institute of High Energy Physics, Chinese Academy of Science The current status of HXMT and its calibrations.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
The Hard X-ray Modulation Telescope Mission
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
11 th iWoRiD, Prague, Czech Republic Low-power Wide-dynamic-range Readout System for a 64-channel Multi-anode PMT of a Scintillation Gamma Camera Satoru.
Position sensitive scintillation detectors for the trigger system in the space experiment NUCLEON Supervisors: Anatoliy I. Kalinin a Students: Irina Cioara.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
NASA 2001 Mars Odyssey page 1 Workshop HEND Russian Aviation and Space Agency Institute for Space Research Present knowledge of HEND efficiency.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Observation of cosmic gamma-ray bursts and solar flares in the ''RELEC'' experiment on the ''VERNOV'' satellite.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Gamma Spectrometry beyond Chateau Crystal J. Gerl, GSI SPIRAL 2 workshop October 5, 2005 Ideas and suggestions for a calorimeter with spectroscopy capability.
The Status of Hyperball-J Akio Sasaki Dept. of Phys. Tohoku Univ. 23/9/2011.
The dynamic range extension system for the LHAASO-WCDA experiment
Status of ULE-HPGe Experiment for WIMP Search in YangYang
Performance of scintillation pixel detectors with MPPC read-out and digital signal processing Mihael Makek with D. Bosnar, V. Gačić, L. Pavelić, P. Šenjug.
CEPC ScECAL Optimization for the 3th CEPC Physics Software Meeting
from Saint Gobain studies
A. F. Yanin, I. M. Dzaparova, E. A. Gorbacheva, A. N. Kurenya, V. B
Performance of LYSO and CeBr3 crystals readout by SiPM
FINAL YEAR PROJECT 4SSCZ
Synchrotron Radiation Detector Studies
Scintillation Detectors
Institute of High Energy Physics, CAS
Comparison of GAMMA-400 and Fermi-LAT telescopes
Double Beta Decay of 48Ca with CaF2(Eu) - ELEGANT VI -
Dr. Mikhail Runtso, Mr. Pavel Naumov,
  at Super tau-charm
Gamma-ray Large Area Space Telescope
LHAASO-WCDA: Design & Performance
Liquid Xenon Detector for the MEG Experiment
大強度
Sr-84 0n EC/b+ decay search with SrCl2 crystal
GRM brief introduction
PAN-2013: Radiation detectors
R. Bucˇık , K. Kudela and S. N. Kuznetsov
New Study for SiPMs Performance in High Electric Field Environment
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
Neutron Detection with MoNA LISA
Gamma-Gamma Correlations in Na-22
Gamma-ray Spectroscopy technique is commonly used in Planetary Exploration Missions.
Upgrade of LXe gamma-ray detector in MEG experiment
X. Zhu1, 3, Z. Deng1, 3, A. Lan2, X. Sun2, Y. Liu1, 3, Y. Shao2
Background Reduction for Quantitative Gamma-ray Imaging with the Electron-Tracking Compton Camera in High Dose Areas May 26th, PS10A-10 T. Mizumoto,
BESIII EMC electronics
Dark Matter Search with Stilbene Scintillator
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Development of a Large Area Gamma-ray Detector
HE instrument and in-orbit performance
md-NUV PET project meeting
Conceptual design and R&D Progress of STCF ECAL
JSC “Institute in Physical-Technical problems”
ME instrument and in-orbit performance
Design Requirements for Jinping Underground Neutrino Experiment
Status Report on MCP PET Simulation
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

On behalf of the GECAM group A compact low threshold gamma-ray detector composed of LaBr3 and SiPMs for GECAM Xilei Sun On behalf of the GECAM group IHEP, CAS, Beijing China Pisa meeting 2018, Italy, 5.28.2018

Contents Back ground introduction The GECAM project The detectors solution The performance of the detectors Summary

The new era of gravitational wave multi-messenger astronomy 4π ears is ready LIGO Need a new 4π eyes GECAM GW170817A Fermi/GBM

The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) project Proposed in March 2016, prototype funded in July 2016, plan to be launched in 2020. All sky cover, sensitivity~2E-8 erg/cm2/s, 2- 10 events/year. Angle resolution ~1 deg for 1E-5 erg/cm2 Energy area 6 keV-2 MeV. Two micro-satellites in low earth orbit. Within a short period and small budget. 25 Gamma ray detectors, and 8 Charge particle detectors for anticoincidence. The limitation of size, weight and power consumption of micro-satellites are the challenges for the detector design.

The detectors solution PMT, has a large volume and a high operating voltage, which make it inappropriate for microsatellites. SiPM, the performance has been greatly improved over the past decade Compact size Large dynamic range Single-photon sensitivity High photon detection efficiency Insusceptibility to magnetic fields low power supply and consumption However, the high thermal-noise of SiPMs ~100 kHz/mm2 is an obstacle to detect low-energy X-rays especially below 10 keV. So the high light yield and fast decay time of the scintillator are the key factors to suppress the SiPM’s noise for low energy X-rays detection. LaBr3 >60,000 photons/MeV, fast decay time (16 ns) SiPM + LaBr3 is the solution

The detector structure transmission ~80% for 5 keV X-rays absorption efficiency >35% for 1MeV gamma

The test system

The low energy performance The typical waveform of of 5.9 keV X-rays and the dark noise of SiPM at room temperature. The spectra of Fe55 and inner radioactive sources.

Detection Efficiency of 5.9 keV Fe55 5.9 keV 4π 2536 Bq in 2017 Face to the Be window ~2π is 1268 Bq Fe55 +background 1170 Hz, Background 280 Hz, Fe55 count rate is 1170-280=890 Hz 890/1268 Detection Efficiency >70%. Consistent with the simulation

The energy resolution 95.6% @ 5.9 keV FWHM 15.9% @ 59.5 keV FWHM 6.5% @ 662 keV Slightly worse energy resolution mainly affected by two factors compared to traditional PMT: One is the dark noise of the SiPM, both cross talk and after pulse Another is the uniformity of the light collection, the edge position lost more photons than the center position because the square SiPM cannot cover the round crystal window completely.

The Uniformity 50mm light collection efficiency declines 5%-7% as the location moves from the center to the edge

The Linearity 5.6 - 662 keV The maximum signal amplitudes that can be collected by DT5751 is only 1 V, next work is to design dual-gain circuit, high gain for low-energy rays and a low gain for high-energy rays.

The new round SiPM array 76mm Excellent uniformity <1% from 7% Energy resolution 4.1% from 6.5%

Internal radiation the internal La138, Ac227 ~1 cps/cc 5.6 keV, 1.4 MeV peaks can be used to do the detector calibration in space

Summary GECAM is proposed for the All-sky searches for the GRB from gravitational wave events. launched in 2020, two microsatellites, 2-10 events/year A low-energy sensitive compact gamma-ray detector has been developed for GECAM and works well Based on LaBr3 and SiPM, one readout channel Low energy x-ray to ~6 keV Energy resolution 4%@662keV Efficiency of 5.9 keV >70% Uniformity <1% Internal radiation for calibration