Best-in-class modular UPS ensuring business continuity

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Static Transfer Switch
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
G.E. UPS Productline.
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
LP33 Series UPS kVA 400Vac/CE
1 Presentation Protect ph ~ / 3 ph ~ transformerless 3 ph ~ / 1 ph ~ 3 ph ~ / 3 ph ~ PROTECT PROTECT PROTECT PROTECT
DPA TM UPScale Best-in-class modular UPS for maximum availability.
NT series introduction UPS training June 2006 Markus Schwab.
UPS H series introduction UPS training June 2006 Markus Schwab.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004.
UPS SG-CE Series kVA Sales presentation.
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Newave SA, Switzerland – - 28/02/ Conceptpower Modular 80 and 100kVA THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT.
Janus Convertible Line – interactive Series UPS
AC backup solutions for business continuity. Secure your business, Stay on!
POWER PLANT USED IN TELECOM
MarsⅡ On-Line UPS Series
ENERGY of 21 st Century Independent Power Supplies.
CONCEPTPOWER DPATM Newave unique MODULAR power protection concept for mission critical applications Conceptpower DPA 28 March 2011.
PowerScale 10-50kVA Ed Maximize your availability.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Modular Inverter.
Delivering total power infrastructures worldwide for IBM.
RACK Mountable & Modular Continuous Power Protection Availability
Today’s presenters: Carlo Quiriconi Technical Services Manager Graham Higginson Area Manager Qld
Power Protection Stowe Australia Welcomes QESTnet Data Centre Construction Workshop Seminar Stowe Australia Welcomes QESTnet Data Centre Construction Workshop.
Power Quality Product Overview
LP Series 400V CE GE Consumer & Industrial September 2004.
TLE Series UPS kW CE. Page 2 TLE Series kVA/kW CE Product Range TLE Series UPS kVA/KW 160,200,320,400 kW High efficiency UPS Introducing.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
KSA 16th of March. UPSUPS (Uninterruptible Power Supply) is a device which supply energy without interruptions to other electric devices. It uses batteries.
LEADING THE PACK.
FLATPACK Rev.5 September 2002 Updated versions may be available.
InfraStruXure Systems Alex Tavakalov
UPS SG-CE Series 300 kVA. SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V.
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Poseidon 4002 Rack monitoring.
Avaya VA Line-interactive UPS
Avaya Online UPS 6000 VA.
RACK Mountable & Modular Continuous Power Protection Availability
Avaya Online UPS 6000 VA.
RACK Mountable & Modular Continuous Power Protection Availability
VH Series How to Compete Against…
Liebert APS.
Power distribution and UPS in a single, compact system
PowerValue 11 RT Sales Presentation
True modular UPS system for critical applications
Maximize your availability
PowerValue 11/31 T Sales Presentation
The new industry standard (1 UPS for 15,000 ft2)
Its strengths, your benefits
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
600 V HIGH VOLTAGE SOLUTION η μ.
Presentation transcript:

Best-in-class modular UPS ensuring business continuity DPATM UPScale ST S2 Best-in-class modular UPS ensuring business continuity

DPA UPScale ST S2 Content Introduction Key benefits Product overview Available ST models M10 & M20 modules Vertical & horizontal scalability Parallel system configuration Hybrid system configurations Options Maintenance & Service © ABB November 12, 2018

Best-in class for growing infrastructures DPA UPScale ST S2 Best-in class for growing infrastructures kW DPA UPScale ST 200 180 160 140 120 100 80 60 40 20 10 DPA UPScale ST is an online double conversion uninterruptible power supply (UPS) system that will secure the power supply to small –medium data center and control process systems avoiding downtime cost and lost data. It is a 3ph transformerless UPS based on a modular decentralized parallel architecture (DPA). In DPA, each module share no common components and has a fully functional UPS so a DPA parallel system offers extremely high system reliability and uptime is maximized ST 200 ST 120 ST 80 ST 60* ST 40* DPA UPScale power range vs ST models The modular architecture of the DPA UPScale ST allows flexible scalability, high availability, all in one solution*, easy serviceability, and lower Total Cost of Ownership (TCO). © ABB (*) including frame, power modules, I/O section and internal batteries November 12, 2018

DPA UPScale ST S2 Key Benefits 99.9999% (6 nines) availability Decentralized Parallel Architecture No single points of failure Redundant capacity (N+1) per frame Replace or add modules with no downtime Short mean time to repair All-in-one solution Power range from 10 kW to 200 kW in a single frame Internal battery modules for short autonomies and external battery cabinets for long autonomies User friendly interface per module and system level Remote control and monitoring options available Low total cost of ownership Up to 96% true online efficiency Eco-mode efficiency ≥ 98% Unity power factor (kW = kVA) Low input harmonic distortion (THDi < 3%) Small footprint / high power density 472 kW / m2) Efficient service concept Simple power upgrade Fast maintenance Full front access Reduced spare parts needed © ABB November 12, 2018

DPA UPScale ST S2 Product Overview Technical Highlights Classification IEC/EN 62040-3 VFI-SS-111 Topology on-line double conversion Type 3 phase transformerless System power rating 10kW– 200 kW Module power rating 10kW, 20kW Maximum power per frame 200 kW / 10 modules Maximum parallel module 20 modules / 4 frames Maximum power system (N+) 380 kW Overall efficiency 96% Efficiency in eco-mode 98% Ouput power factor 1 Input current distorsion THDi < 3% Cabinet Size (HxWXD) ST40/ST80 1135 x 550 x 775 ST60/ST120/ST200 1975 x 550 x 775 Footprint 0.42m2 Power density per m² up to 472 kW/m² Internal battery modules VLRA ST40 up to 80 x 7/9Ah ST60 up to 240 x 7/9Ah Control & Monitoring   Module LCD control panel System Graphical display (option) Customer interface in/out dry contact, RS-232 Nerwork management interface SNMP, Modbus TCP (option) Up to 10 DPA modules Customer input & output interfaces Parallel Interface Maintenance bypass switch AC I/O terminals & DC battery terminals Graphical Display © ABB November 12, 2018

DPA UPScale ST S2 Available Models PRODUCT TYPES ST 40 ST 60 ST 80 Maximum output power 40 kW 60 kW 80 kW 120 kW 200 kW No. Of internal batteries (7/9 Ah) Up to 80 Up to 240 - Dimensions W x H x D (mm) 550 x 1135 x 775 550 x 1975 x 775 Weight frame (without modules/ without batteries) 92 kg 173 kg 82 kg 133 kg 174 kg © ABB Group Month DD, Year

DPA UPScale ST2 M10 & M20 modules Module Type M 10 M 20 Module rated power 10 20 AC electrical network TN, TT, 3ph + N Nominal Input voltage [V] 3x380/220V+N, 3x400V/230V+N, 3x415/240V+N Input frequency 35-70Hz Battery type VLRA, NiCd VRLA 12V battery blocks @ max output rated power 34-50 48-50 Battery charger capacity 10% Nominal output voltage [V] 3x380/220V or 3x400/230V or 3x415/240V Overload capacity on inverter 125 %load 10 min. 150 %load 60 sec. Output frequency [Hz] 50 or 60 (selectable) Weight 18.6 or 21.5 kg Dimensions W x H x D (mm) 488 x 132 x 540 (3HU) Control panel Static bypass Rectifier Inverter Battery charger © ABB Group Month DD, Year

Vertical and horizontal scalability DPA UPScale ST S2 Vertical and horizontal scalability Highlights: Vertical scalable power from 10kW up to 200kW (180kW N+1) in a single frame Horizontal scalable power to increase the capacity up to 400kW (380 N+1) 200kW + 200 kW Cable type ST 40 ST 60 ST 80 ST 120 ST 200 Number of modules per frame 2 3 4 6 10 Parallel frames per system Max number of modules per system 8 12 16 18 20 Max. total system capacity w/o redundancy 160 kW 240 kW 320 kW 360 kW 400 kW © ABB November 12, 2018

Parallel system configuration DPA UPScale ST S2 Parallel system configuration UPS A UPS B The parallel system configuration is delivered with: System Configuration UPS A UPS B Graphical display • _ Parallel Interface Parallel cable 5,10,15,20,25m System graphical display Parallel Interface Parallel Cable © ABB November 12, 2018

ST200 ST120 = 320kW + DPA UPScale ST S2 Hybrid configuration Key benefits Small foot print with high power density (max 2 Frames) Lower total cost of ownership + ST120 = 320kW KW 220 240 260 280 300 320 340 360 380 400 ST 60 1 ST120 2 ST200 Foot Print [W x D] mm 1100 x 775 © ABB November 12, 2018

Options – System & Power Module DPA UPScale ST S2 Options – System & Power Module DPA UPScale ST S2 Frames Modules   Option ST40 ST60 ST80 ST120 ST200 M10 M20 System Backfeed protection • -  Power Module Battery start  - Battery charger enhancement Output short capability 3xIn Wiring Halogen free cable Mechanics Back plinth Backfeed protection (BFP) Battery Start Battery charger enhacement Output short capability 3 x In BFP in the UPS prevent the occurrence of any hazardous voltage or energy from being present on the UPS input a.c. terminals after interruption of the input a.c. power. The battery start function allows starting a UPS from the battery power in the absence of the input main supply. It means the inverter is started with energy from the battery only and the load is supplied with the battery energy via the inverter. Battery charger enhancement increases the battery charger current from 4A up to max 6A. Increase the output short circuit capability of the DPA UPScale power module M20 to 3 x In during 40ms © ABB November 12, 2018

DPA UPScale ST S2 Control & Monitoring Network interface card (option) RS-485 port (remote panel) RS-232 USP Port (Smart Port for monitoring) Output dry ports (5 voltage free contacts) Input dry ports (5 voltage free contacts) RS-232 D-Sub 9P port (Smart Port for monitoring) The network interface card provides:   Remote monitoring via Web Environmental monitoring Extensive alarm handling and dispatching Redundant UPS monitoring Integration into network or building management system Integration into multivendor and multiplatform environments CS121 Basic CS 121 Advanced For interfacing UPS with the network without additional environmental interfaces (sensors) Support following protocols: SNMP Modbus TCP, HTTP Telnet FPT, SMTP (e-mail) For interfacing UPS with the network allowing user to connect additional sensors to monitor the environment. Modbus RS-485 © ABB November 12, 2018

Efficient service concept DPA UPScale ST S2 Efficient service concept Modular concept benefits for maintenance and service Limited spare parts inventory in quantities & part numbers Standardized service practices Minimized risk for human errors UPS service with ABB’s online swappable modules: Replace or add modules with no downtime Simple power upgrade DPA UPScale ST allows efficient service Front access for maintenance and service © ABB November 12, 2018