Science Learning Center Chemistry Pre-laboratory Tutorials

Slides:



Advertisements
Similar presentations
Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz.
Advertisements

Using TI graphing calculators
Solving Equations Numerically Figure 4.1a Rename the independent variable x if necessary. For Figure 4.1a, Set up the table. Set up the first column for.
Solving Equations Numerically Figure 2.1a Rename the independent variable x if necessary. For Figure 2.1a, Set up the table. Set up the column for the.
TI-84 Data Fitting Tutorial Prepared for Math Link Participants By Tony Peressini and Rick Meyer Modified for TI-84 / TI-84 Plus by Tom Anderson, Feb.
Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz.
Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz.
The TI-83 Plus Elementary Algebra Calculator Tutorial.
Solving Systems of Equations. Graphing There are three methods to solving systems of equations by graphing: 1)Write both equations in slope – intercept.
Texas Instruments TI-83 Plus Graphing Calculator Basic Operations.
Plotting coordinates into your TI 84 Plus Calculator.
Calculating Variance using the TI 83+ or TI 84+ To be used to instruct in the use of the Texas Instruments calculators for Chapter 16 1.
Lesson 13 Graphing linear equations. Graphing equations in 2 variables 1) Construct a table of values. Choose a reasonable value for x and solve the.
TI 84 Graphing Calculator Project Example Simple Sailboat.
Section 8.1/8.2 Matrix Solutions to Linear Systems Inconsistent and Dependent Systems.
TI89 and Voyage 200 Student Support Services Presented by Andy Williamson and Amanda Griffin.
Check it out! 4.3.3: Distinguishing Between Correlation and Causation
Using the TI-83+ Creating Graphs with Data. Preparing to Graph  Once the calculator is on and you have entered data into your lists, press the “Y=“ button.
Light Gates –To Collect Data Not Connected To Computer 1.Press enter to select timing 2.Press or to select Set Timing Mode 3.Press Enter 4.Press or to.
Dealing with Data Basic Steps to Using the TI-83 Graphing Calculator.
A useful tool..  (Formerly) tiny computers – you can even program them.  TI-83+, TI-84+, TI-89 are the ones with which I am most familiar.  There are.
TI – 83 Plus1 A Quick Reference Presentation for AMSTI Year 1 Training.
The Pressure Law Using ALBA Interfacing D Burrett Physics Department Hermitage Academy Argyll & Bute.
TI-84 Lists of Data Store the data values to be analyzed using statistical techniques.
12/5/2015 V. J. Motto 1 Chapter 1: Linear Models V. J. Motto M110 Modeling with Elementary Functions 1.4 Linear Data Sets and “STAT”
For all work in this unit using TI 84 Graphing Calculator the Diagnostics must be turned on. To do so, select CATALOGUE, use ALPHA key to enter the letter.
2016-USING TECHNOLOGY FOR PROBLEM-SOLVING IN SCIENCE OLYMPIAD KAREN LANCOUR Life Science Rules Committee Chair.
Figure 1.1a Evaluating Expressions To evaluate an algebraic expression, we may substitute the values for the variables and evaluate the numeric expression.
When you finish your assessment In 2-3 complete sentences answer each question 1. How is the first unit going for you so far in this class? 2. If you are.
How to Master the Calculator By Werbin, Anthony & Montesi, Mick.
Graphing Calculator Steps Steps to follow to find the vertex of a parabola & to find the zeros of a parabola. Make sure you view this in presentation mode.
Saving TI-83 List Data to a Program File. Saving TI-83 Lists to a Program Step 1: Create a New Program Press PRGM and arrow over to NEW Press ENTER and.
Unit 3 Section : Regression Lines on the TI  Step 1: Enter the scatter plot data into L1 and L2  Step 2 : Plot your scatter plot  Remember.
Using the TI-83+ Using Lists. Finding the lists  Once the calculator is on, press the STAT key. This key is located in the middle column under the DEL.
Linear Regression A step-by-step tutorial… Copyright © 2007 College of the Redwoods First edition by Aeron Ives.
TI-83 Plus. GraphLink: an interface helps us to exchange data between a PC and the TI- calculators.
Using the calculator to find the Line of Best Fit For the TI – 84 Plus.
Introducing your TI-83/84 Plus Graphing Calculator
Vernier Equipment Understanding the Basics of Vernier Technology and Tools Part 2: External Probes and Networking.
x2 x-1 x3 π . EXP Ans = – x ÷ DEL AC ^ x! d/c RCL
Graphing Linear Equations
Graphing Histograms on the Calculator
Questions? Standard. Questions? Standard Questions? Honors.
Calculations with Lists
3.2 Residuals and the Least-Squares Regression Line
Exercise 4 Find the value of k such that the line passing through the points (−4, 2k) and (k, −5) has slope −1.
Science Learning Center Chemistry Pre-laboratory Tutorials
1.3 Modeling with Linear Functions
we use a TI-82 to find the equation:
Science Learning Center Chemistry Pre-laboratory Tutorials
USING TECHNOLOGY FOR PROBLEM-SOLVING IN SCIENCE OLYMPIAD
Scatter Plots on the Graphing Calculator
Science Learning Center Chemistry Pre-laboratory Tutorials
Make a name tent and put your name on both sides.
Sine Waves Part II: Data Analysis.
4.9 Modeling with Polynomial Functions
Sine Waves Part II: Data Analysis.
Saving TI-83 List Data to a Program File
Parametric Equations Lesson 10.1.
Exponential Functions
Slope Fields and Euler’s Method
Scatter Plots on the Graphing Calculator
Introduction Digital Mood Ring with TI-84 Plus CE and TI-Innovator™ Hub student STEM project Bring science and coding together (no coding experience.
1.3 Exponential Functions
TI-83 Plus Graphing Calculator
Graphing linear equations
1.3 Exponential Functions
9.6 Modeling with Trigonometric Functions
Finding Statistics from Data
Finding Statistics from a frequency table
Presentation transcript:

Science Learning Center Chemistry Pre-laboratory Tutorials Written By Patrick Herklotz

Menu Options: Click on Links To… Instructions Step # Location of Written Instructions Menu Options: Click on Links To… Previous Slide Link: Go to Preceding Slide Link: Watch Current Slide Animations Again Replay Continue Link: Advance to Next Slide

Calibrating and Operating the Vernier pH Sensor Tutorial 4 Calibrating and Operating the Vernier pH Sensor

Calibrating and Operating the Vernier pH Sensor Tutorial 4 Calibrating and Operating the Vernier pH Sensor Previous Slide Replay Continue

Step 1: Assemble the LabPro Calculator as explained in Tutorial 1 Previous Slide Step 1: Assemble the LabPro Calculator as explained in Tutorial 1 Replay Continue Top View Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > )

Step 1: Assemble the LabPro Calculator as explained in Tutorial 1. Previous Slide Step 1: Assemble the LabPro Calculator as explained in Tutorial 1. Replay Continue Top View Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > )

Previous Slide Step 2: Obtain the pH sensor and plug it into channel 1. Run the DataMate program by selecting it from the APPS menu in order to allow the calculator to detect the pH sensor. Replay Continue Top View Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) Channel 1 Channel 2 Channel 3 Channel 4 Side View

Previous Slide Step 2: Obtain the pH sensor and plug it into channel 1. Run the DataMate program by selecting it from the APPS menu in order to allow the calculator to detect the pH sensor. Replay Continue Top View Power Supply pH SENSOR LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) VERNIER SOFTWARE DATAMATE (VER 1.15) ROM 6.27 (C)2003 Checking Sensors Mode: TIME GRAPH-180 1: SETUP 4: ANALYZE 2: START 5: TOOLS 3: GRAPH 6: QUIT CH 1: Absorbance 0.475 Mode: TIME GRAPH-180 1: SETUP 4: ANALYZE 2: START 5: TOOLS 3: GRAPH 6: QUIT click Channel 1 Channel 2 Channel 3 Channel 4 Channel 1 Port Side View

LabPro Calculator Screen Previous Slide Step 3: In the default DataMate program screen, press the 1 key (SETUP). In the next menu, press 2 (CALIBRATE) once the cursor triangle is to the left of CH 1. In the third menu, press the 2 key (CALIBRATE NOW). Replay Continue Power Supply pH SENSOR LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) Texas Instruments TI-84 Silver Edition CH 1: PH Mode: TIME GRAPH-180 1: SETUP 4: ANALYZE 2: START 5: TOOLS 3: GRAPH 6: QUIT LabPro Calculator Screen

LabPro Calculator Screen Previous Slide Step 3: In the default DataMate program screen, press the 1 key (SETUP). In the next menu, press 2 (CALIBRATE) once the cursor triangle is to the left of CH 1. In the third menu, press the 2 key (CALIBRATE NOW). Replay Continue Power Supply pH SENSOR LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) Texas Instruments TI-84 Silver Edition CH 1: PH Mode: TIME GRAPH-180 1: SETUP 4: ANALYZE 2: START 5: TOOLS 3: GRAPH 6: QUIT CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 2.627 POINT 2: CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 0 4 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY CH 1: PH CH 2: CH 3: CH 4: DIG1: DIG2: MODE: TIME GRAPH-900 1:OK 3:ZERO 2:CALIBRATE 4:SAVE/LOAD LabPro Calculator Screen

LabPro Calculator Screen Step 4: Remove the pH sensor from the solution bottle that keeps it moist. Thoroughly rinse the pH electrode with DI water over a beaker. Always perform this step before measuring the pH of a new solution. Use a Chemwipe to gently rub off strong bases from the sensor’s electrode after rinsing it with DI water. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR 50 100 150 250 300 0 ml Texas Instruments TI-84 Silver Edition CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 2.627 POINT 2: LabPro Calculator Screen

LabPro Calculator Screen Step 4: Remove the pH sensor from the solution bottle that keeps it moist. Thoroughly rinse the pH electrode with DI water over a beaker. Always perform this step before measuring the pH of a new solution. Use a Chemwipe to gently rub off strong bases from the sensor’s electrode after rinsing it with DI water. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR Rinse pH electrode with DI water from lab squeeze bottles. 50 100 150 250 300 0 ml Texas Instruments TI-84 Silver Edition CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 2.627 POINT 2: LabPro Calculator Screen

LabPro Calculator Screen Step 5: Place the sensor electrode into a buffer that has a pH of 4. Allow the voltage to stabilize to a reasonably constant value out to the hundredth place past the decimal. This may take 10-15 seconds. Once this occurs, press the ENTER key. On the next screen, press the 4 key to input the pH of this buffer into the calculators memory. Press the ENTER Key again. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR 50 100 150 250 300 0 ml pH 4 Buffer Texas Instruments TI-84 Silver Edition CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: LabPro Calculator Screen

LabPro Calculator Screen Step 5: Place the sensor electrode into a buffer that has a pH of 4. Allow the voltage to stabilize to a reasonably constant value out to the hundredth place past the decimal. This may take 10-15 seconds. Once this occurs, press the ENTER key. On the next screen, press the 4 key to input the pH of this buffer into the calculators memory. Press the ENTER Key again. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR 50 100 150 250 300 0 ml pH 4 Buffer Texas Instruments TI-84 Silver Edition CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: POINT 2: 1 ENTER VALUE ? CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 4 1.635 POINT 2: 4 LabPro Calculator Screen 1.635 1.729 1.631

LabPro Calculator Screen Step 6: Rinse the electrode with DI water. Next, place the pH electrode into a buffer that has a pH of 7. Allow the voltage to stabilize to a reasonably constant value out to the hundredths place past the decimal. Once this occurs, press the ENTER key. On the next screen, press the 7 key to input the pH of this buffer into the calculators memory. Press ENTER to complete the calibrating process. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR 50 100 150 250 300 0 ml pH 7 Buffer Texas Instruments TI-84 Silver Edition CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 4 1.635 POINT 2: 7 3.971 LabPro Calculator Screen

The pH sensor is now calibrated! LabPro Calculator Screen Step 6: Rinse the electrode with DI water. Next, place the pH electrode into a buffer that has a pH of 7. Allow the voltage to stabilize to a reasonably constant value out to the hundredths place past the decimal. Once this occurs, press the ENTER key. On the next screen, press the 7 key to input the pH of this buffer into the calculators memory. Press ENTER to complete the calibrating process. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR 50 100 150 250 300 0 ml The pH sensor is now calibrated! pH 7 Buffer Texas Instruments TI-84 Silver Edition CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 819 -21364 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY 1 ENTER VALUE ? CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 4 1.635 POINT 2: 7 3.971 CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 4 1.635 POINT 2: 7 LabPro Calculator Screen 3.971 4.452 3.976

Step 7: Press the 1 key [OK] to return to the Settings menu Step 7: Press the 1 key [OK] to return to the Settings menu. Press the 1 key [OK] again to return to the main menu. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR 50 100 150 250 300 0 ml Texas Instruments TI-84 Silver Edition CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 819 -21364 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY

pH reading for a solution Step 7: Press the 1 key [OK] to return to the Settings menu. Press the 1 key [OK] again to return to the main menu. Previous Slide Replay Continue - Power Supply LabPro VERNIER Quick Setup Start/Stop Transfer Vernier STAT PLOT F1 TBLSET F2 FORNAT F3 CALC F4 TABLE F5 Alpha 2ND Mode DEL STAT PRGM COS ( X,T,O,N APPS MATH 7 4 1 8 5 2 . 9 6 3 (-) x + - ÷ Enter X -1 X2 LOG LN STO> ON SIN , VARS CLEAR TAN > ) pH SENSOR 50 100 150 250 300 0 ml Texas Instruments TI-84 Silver Edition CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 819 -21364 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY CH 1: PH CH 2: CH 3: CH 4: DIG1: DIG2: MODE: TIME GRAPH-900 1:OK 3:ZERO 2:CALIBRATE 4:SAVE/LOAD CH 1: PH 7 Mode: TIME GRAPH-180 1: SETUP 4: ANALYZE 2: START 5: TOOLS 3: GRAPH 6: QUIT pH reading for a solution

Calibrating The pH Sensor: Review of Steps 5-7 Previous Slide Calibrating The pH Sensor: Review of Steps 5-7 Replay Continue Texas Instruments Texas Instruments Texas Instruments TI-84 Silver Edition TI-84 Silver Edition TI-84 Silver Edition CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 0 4 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 2.627 POINT 2: 1 ENTER VALUE ? 4 (1) Press 2: CALIBRATE NOW (3) Press 4 Key then the ENTER Key (2) Press ENTER key Texas Instruments Texas Instruments Texas Instruments TI-84 Silver Edition TI-84 Silver Edition TI-84 Silver Edition CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 4 1.635 POINT 2: 3.458 2 ENTER VALUE ? 7 CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 819 -21364 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY (5) Press 7 key then the ENTER key (6) Press 1 twice to return to default menu screen (4) Press ENTER key

Calibrating The pH Sensor: Review of Steps 5-7 Previous Slide Calibrating The pH Sensor: Review of Steps 5-7 Replay Continue Texas Instruments Texas Instruments Texas Instruments TI-84 Silver Edition TI-84 Silver Edition TI-84 Silver Edition CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 0 4 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 2.627 POINT 2: 1 ENTER VALUE ? 4 (1) Press 2: CALIBRATE NOW (3) Press 4 Key then the ENTER Key (2) Press ENTER key Texas Instruments Texas Instruments Texas Instruments TI-84 Silver Edition TI-84 Silver Edition TI-84 Silver Edition CALIBRATION SENSOR MONITOR VOLTAGE, WHEN STABLE,PRESS [ENTER]. VALUE VOLTAGE POINT 1: 4 1.635 POINT 2: 3.458 2 ENTER VALUE ? 7 CALIBRATION PH CALIBRATION: LINEAR SLOPE INT 819 -21364 1:OK 2:CALIBRATE NOW 3:MANUAL ENTRY (5) Press 7 key then the ENTER key (6) Press 1 twice to return to default menu screen (4) Press ENTER key

End of Tutorial 4 Menu Options Back to Beginning Previous Slide Finished