Foundation Systems
Introduction All structures require a foundation Foundations provide a base to distribute the weight of the building to the soil Must resist loads from gravity, floods, winds, and earthquakes.
Soil Considerations Nature of soil Classification/Names of conditions Types/Textures Bearing capacity/Compaction Classification/Names of conditions Climate
Soil Types Bearing Cap Rock 5000 or 20% crushing value Sand Clay Course 1500 Fine 1000 Clay Hard 3000 Sandy 2000 Soft 1000 Adobe 1000 Silt 500
Soil Classifications and Names of Conditions 1--Natural grade 2--Existing grade 3--Finished grade 4--Backfill 5--Compacted Fill 6--Uncompacted Fill 7--Cut
Climate Conditions Frost Depth Chart, see text
Climate Considerations Freezing Know local conditions Depth requirement 12” below average frost depth Follow design rule for sizing footing width = 2 x foundation thickness depth = foundation thickness Water Content permeability of soil--water absorbed into soil causes expansion
Type of Foundations “Tee” or “T” foundation (Continuous or Spread foundation) Slab (On-grade) foundation sometimes called monolithic concrete slab foundation Pier foundation
What the Foundation Looks Like Like Class Project Spread and Slab Foundations Sectional view Plan view
Tee Foundation W/ Interior Footings
What the Pier Foundation Looks Like Plan view, Exterior or side view, Perspective
Special Foundation Conditions Fireplace Footings, extends 6” beyond Foundation height out of ground (set by code): 6”-8” above grade, usually 8” Stepped foundation: 32” horizontal minimum 24” vertical maximum Anchor bolts: 5/8” x 12” AB @ 32” OC Reinforcing requirements Rebar sizes given in # of 1/8” diameters. Example #4 = 1/2” Dia. Range from #2 to #18 diameter
Stepped Foundation
Reinforcing Bars (Rebar) Identification Marks: 1--Steel Manuf (Mill) 2--Bar Size(no. of 1/8 dia) 3--Type of steel(grades) N = new billet steel I = rail steel A = axle steel 4--Minimum yield (psi) 40K, 50K, 60K, 75K
Foundation Dimensioning Foundation walls outside surface/jogs/etc. Piers/beams always to center of piers or beams Vents dimension to actual opening Access doors location and size dimensions req’d
Foundation Dimensioning Example
Foundation Vents Sizing 1 sq ft ventilation for each 150 sq ft of crawl space area First, determine crawl space area Second, Area (x) 1/150 = total net vent sized(TNVS) TNVS () net area of one vent = # vents required (round up) (Use product supply literature)
Foundation Ventilation 1/150 1/1500
Product Supply Literature
Crawl Space Access All crawl spaces must have access provided Type/Location of access floor to crawl space (possibly in closet or under stairs) outside access through foundation Codes vary for size UBC--18”x30” min CABO--18” x 24” min SBC--18” x 24” min IRC—18” x 24” min
Fireplace Construction and Drafting
Introduction How many of you have a fireplace in your home? Is it your major source of heating? Fireplaces today are more of a luxury item major element of interior design in living area provide atmosphere minor concern for heat
Fireplace Design and Construction Type and style Structural framing around fireplace Size & type of opening Chimney design/height above roof Fireplace terminology/function Flue sizing Fireplace drawings
Common Fireplace Types 1--Single faced flush hearth raised hearth 2--Double faced corner designs 3--Double faced opposite sides design 4--Three faced 5--Free standing
Double Faced Fireplace
Double Faced Opposite Sides FP
Three Faced Fireplace
Structural Framing Requirements No wood or combustible material is allowed to touch any part of the fireplace, its foundation, or chimney 2” clearance usually required by code No structural piece should rest on the fireplace and use it as support
Structural Framing Note double headers & trimmers opening < 10’ ledger strip or Joist hangers fireplace & chimney free-standing & self-supporting (from FP below) (or Joist hangers)
Flashing Around Chimney Drawing callout: 26 GA GI FLASHING Note flashing callout saddle or “cricket”--diverts water away from behind the chimney
Chimney Heights Building Code: (2 foot 10 foot rule) Chimney 2’ minimum above any construction within 10’ of the chimney
Chimney Flues Area through which the combustion gases and smoke travel Flue liners used to prevent deterioration to mortar joints produces a better downdraft & requires smaller flue (smoother surface) Unlined Flue Chimney must be thicker walls than with chimney with flues liners
Chimney Flues Each fireplace requires a separate flue may be contained within same chimney minimum of 4” distance apart must be different heights, min of 4” from top 4” Min
Chimney Cap Spark Arrester keeps water away from lining stops downdrafts Spark Arrester screen device that prevents sparks from leaving the chimney & passing onto the roof
Fireplace Terms 1. Firebox--opening 8. Damper-- 2. Hearth--min 16” sizes vary prefered 20” 9. Throat 3. Ash dump 10. Smoke 4. Ash pit chamber 5. Clean out 11. Smoke 6. Steel angle or lintel shelf 7. Mantel 12. Flue 13. Chimney
Fireplace Terms/Drafting Layout
Fireplace Function Smoke Chamber 1. Transition from the firebox to the flue 2. Responsible for controlling & regulating burning and eliminating smoke & combustion gases Smoke Shelf 1. Prevent downdraft 2. Help divert cold air into smoke chamber Throat 1. Channels smoke into chamber Damper 1. Controls air flow/shut off when not in use
Flue Sizing Crucial that fireplace opening be in proper proportion to flue for proper operation Inside free space of flue called effective flue area, expressed as fraction Effective flue area (EFA) 1/10 minimum allowed (10%) 1/8 preferred (12%)
Flue Sizing Find affected firebox area based on type of fireplace Area = h x w Find affected firebox area based on type of fireplace Single faced Area = h (x) w Multiply by Ratio if 30” wide x 26” high Area = 30 (x) 26 =780 sq in Effective Flue Area (EFA) (Considering Min EFA 10%) Therefore 780/10 = 78 sq in See tables to select proper flue Dbl-faced Area = 2(h x w) Area = 2(w x h) + d x h
Flue Shapes, Sizes, and Areas See Text for a similar table to the table below showing flue lining sizes, etc. Table relates only designs for 10% EFA, flue areas are okay
Flue Sizing find width at bottom find height at left find intersection find nearest curve above intersection
Fireplace Drawings Required Drawings (see by code or city) Enlarged Plan view like the floor plan but to include dimensions to build Vertical Section shows all vertical relationships including dimensions Elevation of Fireplace front view shows what the fireplaces looks like when finished Common scales: 3/8” = 1’-0” and 1/2” = 1’-0” Views are arranges by orthographic projection height and/or width must align from view to view
Fireplace Assignment (w)
Fireplace Drafting Layout