Φ 3. Transformer Models. Turns ratio 7200:240 (30 : 1)

Slides:



Advertisements
Similar presentations
Chapter 12 Transformers. Chapter 12 Transformers.
Advertisements

ENERGY CONVERSION ONE (Course 25741)
ARRDEKTA INSTITUTE OF TECHNOLOGY ♦ GUIDED BY ♦ Prof. D.R.PATE Asst.prof in electrical Department PREPARED BY PREPARED BY RATHOD VISHANU. RATHOD VISHANU.
Department of Electrical and Computer Engineering EE18B.
Announcements Be reading Chapter 3
Transformers and Coupled Circuits
Unit 27 Three-Phase Circuits
Transformer.
Transformer with open secondary.
Chapter 2 Transformers.
BENE 1113 PRINCIPLES OF ELECTRICAL AND ELECTRONICS
Single Phase Transformer
1.6 Real Single-Phase Transformer.
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
Announcements For lectures 8 to 10 please be reading Chapter 3
Announcements Please read Chapter 3 H4 is 4.34, 4.41, 5.2, 5.7, 5.16
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
EET 103 Transformer Chapter 5 1. A transformer is a device that changes ac electric energy at one voltage level to ac electric energy at another voltage.
Modeling of Power Transformers A Static Device. Transformers The transformer enables us to utilize different voltage levels across the system for the.
Chapter 2 Transformers Edit by Chi-Shan Yu Electric Machinery.
1 The Transformer 1. 2 X XX X X B field into page L L No voltage on terminals.
CHAPTER 1 Transformer School of Computer and Communication Engineering, UniMAP Prepared By: Amir Razif A. b. Jamil Abdullah EMT 113: V-2008.
BASIC ELECTRICAL TECHNOLOGY DET 211/3 Chapter 6: Single Phase Transformer (Continued)
Magnetic field due to an electric current
Lecture 11Electro Mechanical System1 Delta-Delta Connection  Three single-phase transformers connected delta-delta  H 1 terminal of each transformer.
EKT 451 CHAPTER 1 Transformer.
Lecture 04Electro Mechanical System1 Ideal Transformer  An ideal transformer  Transformer has no losses and core is infinitely permeable  All fluxes.
Instantaneous power p(t) flowing into the box
SMJE 2103 Electrical Power System
SMJE 2103 Electrical Power System 3- Ph Power Apparatus.
1. 2 Magnetization Current in a Real transformer Although the output of the transformer is open circuit, there will still be current flow in the primary.
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
Auto Transformer Current Flow. Principles of Auto Transformers H X H0/X0.
Lesson 12: Parallel Transformers and Autotransformers ET 332b Ac Motors, Generators and Power Systems 1 Lesson 12_et332b.pptx.
Lesson 25: Magnetism and Transformers
Transformer Professor Mohamed A. El-Sharkawi
TRANSFORMER A transformer is a static device.
Lesson 8: Ideal Transformer Theory and Operation
Lesson 10: Transformer Performance and Operation
Announcements Please read Chapter 3
ELECTRICAL ENGINEERING TECHNOLOGY EMT 113/4
B4.2 Power System One-Line Diagrams
ELEC 3105 Basic E&M and Power Engineering
BASIC ELECTRICAL TECHNOLOGY DET 211/3
TRANSFORMER mohd hafiz ismail hafizism, january 2007.
Electric Machine Transformers
Transformer By Rosemizi Abd Rahim
DKT 123 Transformer.
Transformers.
Transformers.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Energy Conversion and Transport George G. Karady & Keith Holbert
1. Power and RMS Values.
UNIT 3 Transformers.
Three Phase Transformers
Lesson 11: Transformer Name Plate Data and Connections
Energy Conversion and Transport George G. Karady & Keith Holbert
11. Magnetically Coupled Circuits
Ch. 13 – Ideal Transformers
Transformer Impedance
Electrical Engineering Principle DNT 235/3
TRANSFORMERS.
Three-Phase Transformers
Transformers.
PRACTICAL TRANSFORMER
Three Phase Transformers
Ch. 13 – Ideal Transformers
Prof.mrs najma siddiqui
Electrical Machines (EELE 3351)
Presentation transcript:

Φ 3. Transformer Models. Turns ratio 7200:240 (30 : 1) (approx. same amount of copper in each winding) Rs jXs Ideal Transformer 7200:240V Rm jXm 7200V 240V Prof. Mack Grady, TAMU Relay Conference Tutorial Topic 3, March 31, 2015

Φ 3. Transformer Models, cont. Open Circuit Test Ioc + Voc - ~ V R || Rs jXs + Ideal Rm jXm Transformer Voc 7200:240V - 7200V 240V Turns ratio 7200:240 Φ Open circuit test: Open circuit the 7200V - side, and apply 240V to the 240V - side. The winding currents are small, so the series terms are negligible. ~ V R || jX = oc m m ~ I oc Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015

Φ 3. Transformer Models, cont. Short Circuit Test Isc + Vsc - Short circuit test: Short circuit the 240V-side, and raise the 7200V-side voltage to a few percent of 7200, until rated current flows. There is almost no core flux so the magnetizing terms are negligible. + Vsc - Isc Rs jXs Ideal Rm jXm Transformer 7200:240V 7200V 240V Turns ratio 7200:240 Φ Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015

3. Transformer Models, cont. Rs jXs Ideal Transformer Rm jXm X / R Ratios for Three - Phase Transformers • 345kV to 138kV, X/R = 10 Substation transformers (e.g., 138kV to 25kV or 12.5kV, X/R = 2, X = 12% 25kV or 12.5kV to 480V, X/R = 1, X = 5% 480V class, X/R = 0.1, X = 1.5% to 4.5% Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015

3. Transformer Models, cont. 1. Given the standard percentage values below for a 125kVA transformer, determine the R’s and X’s in the diagram, in Ω. If the R’s and X’s are moved to the 240V side, compute the new Ω values. If standard open circuit and short circuit tests are performed on this transformer, what will be the P’s and Q’s (Watts and VArs) measured in those tests? Load loss Single Phase Transformer. Percent values on transformer base. Winding 1 kV = 7.2, kVA = 125 Winding 2 kV = 0.24, kVA = 125 %Imag = 0.5 %Load loss = 0.9 %No-load loss = 0.2 %Xs = 2.2 Xs No-load loss Magnetizing current Rs jXs Ideal Transformer 7200:240V Rm jXm 7200V 240V Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015

Annual Feeder Loss Components 3. Transformer Models, cont. EPRI Study, Distribution Feeder Loss Example Annual energy loss = 2.40% • Largest component is transformer no-load • loss (45% of the 2.40%) Transformer No- Load 45% Transformer Load 8% Primary Lines 26% Secondary Lines 21% Annual Feeder Loss Components Modern Distribution Transformer: Load loss at rated load (I2R in conductors) = 0.75% of rated transformer kW. No load loss at rated voltage (magnetizing, core steel) = 0.2% of rated transformer kW. Magnetizing current = 0.5% of rated transformer amperes

Y - 3. Transformer Models, cont. A three-phase transformer can be three separate single-phase transformers, or one large transformer with three sets of windings Y - N1:N2 Rs jXs Ideal Transformer N1 : N2 Rm jXm Wye-Equivalent One-Line Model A N • Reflect to side 2 using individual transformer turns ratio N1:N2 , Standard 345/138kV autotransformers, GY-GY have a tertiary 12.5kV Δ winding to permit circulating 3 rd harmonic current Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015

Δ - Δ 3. Transformer Models, cont. For Modeling a Delta-Delta Connection, Convert the Transformer to Equivalent Wye-Wye Wye-Equivalent One-Line Model Rs jXs A Ideal 3 3 N1:N2 Transformer Rm jXm 3 3 N 1 N 2 : N 3 3 N1:N2 • Convert side 1 impedances from delta to equivalent wye • Then reflect to side 2 using individual transformer turns ratio N1:N2 N1:N2 Δ - Δ Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015

Δ - Y 3. Transformer Models, cont. For Modeling a Delta-Wye Connection, Convert the Transformer to Equivalent Wye-Wye Δ - Y N1:N2 Ideal Transformer 3 Rs 2 : 1 N jXs Rm jXm A Wye-Equivalent One-Line Model Convert side 1 impedances from delta to wye Then reflect to side 2 using three-phase line-to-line turns ratio Has 30° degree phase shift due to line-to-neutral to line-to-line relationship. ANSI standard requires the transformer to be labeled such that high-voltage side leads the low-voltage side by 30° . Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015

Y - Δ 3. Transformer Models, cont. For Modeling a Wye-Delta Connection, Convert the Transformer to Equivalent Wye-Wye Y - Δ N1:N2 Ideal Transformer 3 2 : 1 N jXs Wye-Equivalent One-Line Model A Rs Rm jXm N Reflect to side 2 using three-phase bank line-to-line turns ratio Has 30° degree phase shift due to line-to-neutral to line-to-line relationship. ANSI standard requires the transformer to be labeled such that high-voltage side leads the low-voltage side by 30° Thus, for all configurations, equivalent wye-wye transformer ohms can be reflected from one side to the other using the three-phase bank line-to-line turns ratio Prof. Mack Grady, TAMU Relay Conference Tutorial, Topic 3, March 31, 2015