MZC Multizone.

Slides:



Advertisements
Similar presentations
K series for close control NEW C series for Close control.
Advertisements

Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Chapter 3. HVAC Delivery Systems
Series L Air conditioners for Laboratories.
Smart heat for comfort and safety 1 Self-regulating system to maintain water flow in gutters and downpipes.
Trane Voyager™ rooftop units
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Fan Coil Unit Product Line-up. FCU Home Application Show.
Heating, Ventilating, and Air-Conditioning
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
STAND ALONE CONTROL FOR TERMINALS
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
AIR CONDITIONING ACCESSORIES
Low Temperature Space Heating Systems Dr. Evgueniy Entchev CMX 2012 Learning Forum March 22, 2012.
Variable Frequency Drives VFD Basics
Backdraft Dampers. Backdraft Damper Training Application Backdraft dampers allow air to flow in one direction only and prevent unwanted (hot/cold outside.
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Product Introduction.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Air conditioning – Refreshes your life Applied Systems DAIKIN Fan Coil Units Comfort Applications >> FWB
Lecture Objectives: Learn about automatic control Use life-cycle cost analysis integrated in eQUEST.
Hydronic Balancing „Cocon Q “ Pressure independent dynamic control valve.
Air Side System Evaluation
Close Control Units.
Lecture 16: Zone Air Paths and Air Distribution Units
BUILDING MANAGEMENT SYSTEM
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
I Pag 1 Microchiller 2. I Pag 2 I Pag 3 Information on the display.
2010.
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Heat Exchange Ventilation Heat Exchange Ventilation.
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
Energy Plus & Open Studio Class
Objectives Finish DOAS Control Terminology Types of controllers
the compact air control solution
Lecture Objectives: Define the final project Deliverables and Grading policy Analyze factors that influence accuracy of our modeling study Learn about.
HVAC – Air Handling Unit Heating Ventilating AC =Cooling HVAC – Basic Terms hQ = 200,000 Btu/h CO2 20 cfm/ pers 50 people 1000 cfm cQ assume to = 20 tr.
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
HCB 3-Chap 19B: All-Air_Multizone_Reddy1 Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES Agami Reddy (July 2016) 1)CAV terminal reheat 2)CAV multizone.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Fan Coil Controller FC/S 1.1
Maria’s Restaurant Chapter 1 Section 4
Wega & Wega Power chilled beams
AIR CONDITIONING.
Technology in Architecture
ABB i-bus® EIB Electronic Switch Actuator, 4-fold
BUILDING HEATING AND COOLING
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Types of HVAC Technology Used in Business Establishments
Lecture Objectives: Answer questions related to HW 4
Announcement No project presentations !
Lecture Objectives: Finish with HVAC systems
Voyager II and III – Energy Recovery Modules
Volume Control in fluid distribution systems
Roof Top Unit Overview (MAGNUM)
VED and VEDI VED and VEDI.
Chapter 19B: ALL-AIR SYSTEMS FOR MULTIPLE SPACES
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Announcement No project presentations !
Follow-ups from Classes 8 and 9
Total HVAC Control from anywhere Easy control that can save a fortune
Objective Revie the Cooling Cycle Learn about air distribution systems
Presentation transcript:

MZC Multizone

Plenum with motorized dampers for zone and air control MZC Multizone Plenum with motorized dampers for zone and air control

MZC Multizone Multizone plenum for controlling the flow rate of the air Available for both ON/OFF (PSC) and inverter (ECM) fans Ideal for residential and commercial applications

Characteristics Important Characteristics of the MZC The MZC has been designed for residential and commercial applications The unit combines envrionmental comfort with excellent energy savings MZC adjusts the flow rate of the air along with the damper position to create a comfortable environment MZC is designed to be combined with fan convectors that have asynchronous and brushless motors which are arranged for the distribution of air renewal

Characteristics Distinctive Features of the Structure Galvanized frame with insulation on the outer casing From 2 to 6 inlet zone controllers depending on the model. Each zone controller is provided with a motorized damper. The fan coil may require a MZCSM accessory (option not available on all models, see compatibility) Flange for fresh air, supplied as standard, to connect the plenum MZC to heat a recovery ventilator Ability to install an additional Air Probe (MZCSA) accessory for the control of modulating valves or pressure

Characteristics Independant Distinctive Features Possibility of installng the plenum in the intake (return air) of the fan coil through flanges MZCA (attachment) Electrical Box revresible (RH, LH)

Characteristics Adjustment MZC is accompanied by a thermostat (MZCUI) zone for the setting of the set temperature. The state of the damper (open / closed) is regulated by the temperature set on each room Managment of maximum 6 motorized dampers Flow control for each damper (each output can be set to the maximum oprning and minimum damper) Ability to bind the control to more dampers at the request of the same thermostat (MZCUI or WT10) Enable the funtion “suction plenum” Possibility to parameterize the controller through the serial line supervision

Characteristics Each room can have its own zone and thermostat

Accessory Compatibility MZCAC Cable for connecting the fan coil to a brushless motor MZCBC Electrical system required for connection of the MZC plenum with a fan coil including a brushless motor MZCSM Single module with motorized damper for all models except the MZC220 MZCUI Zone thermostat MZCA Adapter flange for the installation of the plenum also in the intake of the fan convector

Accessory Compatibility WT10 Wireless thermostat WR10 Receiver to two wireless channels for WT10 MZCSA Air probe for the control of modulating valves or pressure VMF-VOC Accessory for the detection of air quality

Compatibility of the MZC Plenum Compatibility of the MZC Plenum with Aermec Fan Convectors *If the plant should require, it is possible to also add in a second time a single module of MZCSM delivery (accessory)

Dimensions

Thank you