Diagnostic Medical Sonography Program

Slides:



Advertisements
Similar presentations
Blood Pressure.
Advertisements

Measuring: -Temperature -Pulse -Blood Pressure -Body mass index
Blood pressure measurement
MEASURING & RECORDING VITAL SIGNS Clinical Rotations.
Blood pressure measurement using mercury sphygmomanometers EHES Training Material.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
Measuring Blood Pressure
NUR 111: SKILL 5-5: ASSESSING ARTERIAL BLOOD PRESSURE ASSESSING A BLOOD PRESSURE : I FEEL THIS IS ONE OF THE MOST IMPORTANT SKILLS, AS A NURSE, THAT YOU.
Vital Signs Review. What is Blood Pressure? Blood pressure measures the force of blood pulsing outwards on your arterial walls. NORMAL ADULT BP is systolic.
Vital Signs Chapter 27 Copyright © 2009, 2006 by Saunders, an imprint of Elsevier Inc. All rights reserved. 1.
Blood pressure measurement PHCL 326 (1+1) Clinical skills for pharmacists.
Lab Activity 26 Blood Pressure & Pulse Portland Community College BI 232.
Measuring & Recording Vital Signs
Blood pressure. Blood pressure Preparation for measurement.
Control of Heartbeat and Monitoring Blood Pressure
Blood pressure - procudure
Blood pressure.
Raynaud’s Disease.
Blood Pressure Assessment
Part 1.  Cause Thrombus (blood clot) Embolism Trauma Crush injuries.
Arterial blood pressure is a measure of the pressure exerted by the blood as it flows through the arteries. The systolic pressure is the pressure of the.
1 Arterial Lines Set Up & Monitoring Union Hospital Emergency Department.
Managing Blood Pressure: It Takes a Team
VITAL SIGNS BLOOD PRESSURE PULSE TEMPERATURE RESPIRATIONS.
Buerger’s Disease A presentation by Jennifer Kent-Baker.
PCI What You Need to Know!. What and Where Radial- advantages  Immediate ambulation  Easily compressible vessel  Less risk of nerve injury  Dual blood.
+ Raynaud’s Phenomenon By: Alison Cunliffe. + What is Raynaud’s Disease Condition resulting in a series of discolorations of the fingers and/or toes after.
Blood pressure reflects the force of the heartbeat and the resistance of the arteries to the pumping action of the heart. *Systolic pressure represents.
Contents Vascular Technology Lecture 6
Blood pressure Lecture 5 Dr. Mervat Abdelrahman M.
BLOOD PRESSURE MEASUREMENT Sharon Jones Chapter 17.
Chapter 5 Baseline Vital Signs and SAMPLE History.
The Arterial Pulse With each contraction ,the left ventricle ejects a volume of blood into the aorta and on into the arterial tree A pressure wave moves.
Please get your assigned computer. Do not turn on until instructed.
Key Points Definition of Blood Pressure A.The measurement of the force of blood against artery walls. 1. Force comes from the pumping of the heart 2. If.
!GUESS THAT PVD! CHOICES: Raynoud’s disease DVT Diabetic foot ulcer
FIRST AID AND EMERGENCY CARE LECTURE 4 Vital Signs.
Diagnostic Medical Sonography Program
Use of Doppler in Wound Care Management’
Blood Pressure Hypertension Orthostatics
Chapter 6 Vital Signs.
Vital Signs: Blood Pressure
Bleeding Disorders Last update
Diagnostic Medical Sonography Program
BIOELECTRONICS 1 Lec10: ch4 Blood Measurements By
Diagnostic Medical Sonography Program
Blood pressure Vital signs.
Photo-Plethysmography
Ultrasound evaluation of the RENAL ARTERIES and the kidney
Respiration & Blood Pressure Recording
Diagnostic Medical Sonography Program
Blood Pressure and Pulse oximetery
Blood Pressure.
Peripheral Arterial Disease
Poiseuille’s Equation
Diagnostic Medical Sonography Program
Vital Signs: Blood Pressure
Blood Pressure August 2015 Blood Pressure.
Diagnostic Medical Sonography Program
Lucy Stopher A/CNS Vascular Surgery
Diagnostic Medical Sonography Program Vascular Technology Lecture 6: Doppler Segmental Pressures of the Upper Extremities Holdorf.
Vital Signs: Blood Pressure
Diagnostic Medical Sonography Program Vascular Technology
Hyun-Sung Lee, MD, Byung-Chul Chang, MD, Youn Jeong Heo, RN 
Diagnostic Medical Sonography Program Vascular Technology
Diagnostic Medical Sonography Program
Blood Pressure Basics.
Continuous – Wave Doppler
Diagnostic Medical Sonography Program Vascular Technology
Presentation transcript:

Diagnostic Medical Sonography Program Vascular Technology Lecture 9: Digital Pressures and Plethysmography Holdorf

Digit Plethysmography and Pressures Capabilities Help detect presence of arterial disease Differentiate fixed arterial obstruction from vasospasm Assess effects of treatment

Limitations Quality of tracings greatly affected by the vasoconstricted state of arteries before testing begins. (Has patient: Come in from cold weather? Been Smoking? Nervous?) With Volume Plethysmography, cuffs applied too tightly can obliterate or diminish the pulse wave forms With Photo Plethysmography improper contact with skin surface will cause poor results Bandages that can’t be removed; ulcerations and or gangrene may prevent placement of cuff or photocell Patient with extremity tremor

Patient positioning Physical principles Toe evaluation: Supine with some elevation of head Finger evaluation: Sitting with arms resting on pillow placed on patient’s lap Physical principles Volume and photo plethysmography principles

Technique - Toes Patient should be kept as warm as possible The study is done in combination with a complete LE arterial exam, or a limited version as an ABI An appropriately sized cuff the width at last 1.2 times that of the toe (2.5 – 3 cm) is applied to base of great toe Equipment does a self calibration when activated Plethysmographic waveforms are recorded for all toes. ( If poor waveforms, warm the toes Usual method of obtaining great toe pressures is PPG; (Photocell as end point detector).

Great toe pressures method Digit cuff placed at base of great toe Photocell securely attached to plantar side of toe using double-stick tape or Velcro strap Pulses recorded: paper speed slowed to 5mm/sec (A) While pulsations are recorded, cuff is inflated to 20-30mmHg above highest brachial pressure No pulsations should be seen (B) Cuff is slowly deflated, watching for return of first pulse to define the pressure level (C)

Technique: Fingers without cold stress Upper extremity arterial study is completed initially Evaluate Doppler signals (triphasic, biphasic, monophasic) and obtain pressures Doppler exam of the palmer arch to verify patency Apply finger cuffs (sized: 2 – 2.5 cm) Pressures and waveforms obtained, using similar method described for toes

Technique: Fingers with cold stress Performed in cases of symptoms occurring due to cold sensitivity (Toes can also be evaluated). After resting stud is performed , hands are immersed in ice cold water for 3 minutes if possible. Following cold stress, waveforms and pressures are obtained: immediately after and five minutes after Document patient symptoms, skin color observations and other pertinent findings on the report form.

Interpretation Normal waveform qualities: Sharp upstroke peak systole Prolonged down-stroke with notch (reflected wave) approximately half way down Amplitude is usually greater than toe tracings

Normal Finger

Abnormal Obstructive waveform qualities Occlusion located anywhere proximal to the tip of finger causes the pulse to assume an “obstructive” form Slow upslope to rounded peak Downslope that bows away from baseline

Abnormal Finger

Abnormal peaked waveform qualities: Upslope is slower than normal Sharp (anacrotic) notch is present Reflected wave located high on the downslope Has characteristics of both normal and obstructive waveforms

Abnormal Peaked Waveform

Following cold immersion, abnormal cold sensitivity is likely if the amplitude fails to return to baseline levels within 5 minutes.

Lecture 9 additional notes Digit Plethysmography and Pressures Quality of tracings greatly affected by the vaso-constricted state of arteries before testing begins. Has the patient come in from cold weather? Been smoking?

You want to increase the volume of blood Again, records volume changes . Example: Inflate cuff Increase the volume of blood Release air When the pulse begins, that is the systolic pressure In the example it is about 70

Technique: Fingers with cold stress Following cold stress, waveforms and pressures are obtained: immediately after and five Minutes after. MOST IMPORTANT. With Raynaud’s will not stabilize. Do not do Do a waveform immediately after. Wait 5 minutes. If ok, then ok. If Raynaud’s, then will Not be ok after 5 minutes. Pressures immediately after are useless.

Abnormal PEAKED waveform qualities. If the waveform is PEAKED, then this is positive for a vasospastic problem. 100% Raynaud’s. No need to put the patient’s hands in the cold water to test. This Peaked waveform is taken with a PPG sensor. Digit pressure measurements Fingers are different than toes.

Homework Chapter 10 Pages 107 – 114 SDMS assignments