Overfill Prevention Technology and Maintenance

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

The idea evolved from two different contractor customers who shared with us a better way to perform hydrostatic testing of DWV piping system. Two different,
Preferred Utilities Manufacturing Corp.
CHAPTER 45 Engine Lubrication.
“The Strength of Experience”
GASFUSE™.
Presented by: Yasra Adowar Petroleum Industry Regulatory Team
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Visit Us At Booth #306 J2 Engineering, Inc. J2 provides Construction and Environmental Services and is a verified Service-Disabled Veteran-Owned Small.
 Established in 1995  Located in Wilmington, NC with a 40,000 Sqft facility.  Specializes in the design and manufacturing of connection solutions. 
2 Fire Fighter Qualifications and Safety Skill Drills.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Installation. Indoor Unit Installation Typical Installation.
Model 12 Intek Horizontal OHV
Petroleum Equipment Institute
L. P. Gas Changing Tanks. Introduction L.P. gases belong to a family of chemical compounds known as hydrocarbons. This means they are made up of hydrogen.
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
ACCA Legislative Conference Underground Storage Tank Compliance
DHHB, 1ID MAINTENANCE Effects of Cold on Military Vehicles.
CARBURETED FUEL SYSTEM
MODULE 7 Unload a Cargo Tank Motor Vehicle (CTMV).
Intermediate SFFMA Objectives: – Hrs received.
2.5.6 Student Book © 2004 Propane Education & Research CouncilPage Operating a Propane Dispenser to Fill Vehicle-Mounted ASME Tanks To safely and.
Connecting to industry 1. 2 Safety Break-away Couplings.
3.4.2 Student Book © 2004 Propane Education & Research CouncilPage Types and Functions of Valves and Fittings Used in Bulk Plant Containers and.
Overview of the 1.
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by B. J. Benton United Pump and Controls, Inc.
Gasoline fuel supply systems Function: store, transport, Pressurize and filter gasoline going to carburetor or fuel injection system.
EVAPORATIVE EMISSION CONTROL SYSTEMS
Spill and Overfill Prevention Alaska Spring 2004.
PROCEDURES TO USE A ROTOTILLER PPT PPT Procedures –Refer to Owner’s Manual for important instructions. –Locate and obey safety precautions.
11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
3.4.3 Student Book © 2004 Propane Education & Research CouncilPage Bulk Plant Emergency Shutdown Equipment and Periodic Examination Methods One.
3.7.7 Student Book © 2004 Propane Education & Research CouncilPage 1 Replacing DOT IM tank valves and fittings requires careful application of precautions.
Firefighter III Module B Water Supply (4-19) (4-19)
+ The Four Stroke Cycle By Elizabeth Fahey. + Outline Time Required: 1-3 classes Grades: 9-12 Background: Lesson is in conjunction with the small engine.
Workshop on Permanent Closure of Single-Walled USTs and Funding Opportunities For Closure and Cleanup.
Model 12 Intek Horizontal OHV
Ships Service Air System
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by Travis Benton United Pump and Controls, Inc.
1 1 Staying in Compliance: Spill and Overfill Presented by: Brent Roth OPW Retail Fueling IPECA UST Seminar 2015.
PSI Fill Station Operator (FSO) General info. on compressors Types of Fill stations Why to fill cylinders in a dry environment Fill station operator responsibilities.
Automotive Engines: Theory and Servicing, 7/e By James D. Halderman Copyright © 2011, 2009, 2005, 2001, 1997 Pearson Education, Inc., Upper Saddle River,
Presented at the Fifth Annual California Unified Program Conference February 6, 2003 Enhanced Vapor Recovery Cindy Castronovo Air Resources Board Cal-EPA.
Discover the Dosmatic Difference Trouble Shooting your Dosmatic injector for years of service.
Horticulture II - Landscape Unit C Landscape Installation and Maintenance.
Temperature Test Allows monitoring of temperature changes.
Edward S. Kubinsky Jr. CROMPCO, LLC
Automotive Heating And Air Conditioning
14 Refrigerant Recovery, Recycling, and Recharging.
The Fuel Delivery System
EVAPORATIVE EMISSION CONTROL SYSTEMS
Staying in Compliance: Spill and Overfill
FIGURE 33-1 A typical fuel tank installation.
DEFENDER SERIES™ OVERFILL PREVENTION
Flammable and Combustible Liquids
Fuel Supply System Service
Alabama Tools Seminars
Introduction to Overfill Prevention for USTs
Valves.
NEW COMPLIANCE REGULATIONS
COMPLIANCE VIOLATIONS FOUND DURING INSPECTIONS
Safety Meeting Topics Standby Generator Safety
Module 4: Storage and Dispensing Locations
Effects of Cold on Military Vehicles
Presentation transcript:

Overfill Prevention Technology and Maintenance OPW Retail Fueling Overfill Prevention Technology and Maintenance

OPW Retail Fueling Overview  Above Ground Products Below Ground Products: Dispensing OPW Piping & Containment Systems Above Ground Storage Tank Equipment OPW Underground Storage Tank Equipment Stage II Vapor Recovery Equipment KPS Petrol Pipe System™ Products CleanEnergy Fueling Products Fibrelite Watertight Composite Manhole Covers, Modular Trench Panels and Underground Enclosures

Ball Float Overview Typical Installation An overfill Indication device installed in the Phase 1 Vapor Recovery Extractor fitting These are most often positioned to close at 90% of the tank capacity Operates by restricting the pathway of vapor exiting the tank to the Phase 1 Vapory Recovery System during a tank fill. Ball Float is lifted by the fuel level, thus increasing the pressure in the tank while dramatically decreasing flow of fuel from the delivery The Delivery hose is effected by the reduction of flow and “kicks” between the fill elbow and the rack on the truck The delivery driver must recognize the “kick” as an indication of the tank being full and shut off flow from the truck to avoid an overfill Installation View From Inside the Tank

Ball Floats, Inspection and Maintenance New Regulations do not allow Ball Floats as Primary Overfill Prevention Device, but some customers still utilize these as backup If installed as a backup device, they must ensure that this is positioned with a shutoff point Above the overfill Prevention Device activation level Bleed Orifice Ball Float From Inside Spill Container Extractor Wrench Preventative Maintenance - Every three years, remove and inspect the valve for damage, contamination, corrosion, freedom of movement of the ball float, and check the bleeder orifice for proper airflow. Replace if damaged or corroded.

How a 71SO Overfill Prevention Device Works Stage 2 – Automatic Overfill Prevention Occurs only if fuel deliverer does not cut off flow from tank Float arm continues to rise, closes secondary orifice Flow is completely shut-off, preventing fuel from reaching tank top Stage 1 – Overfill Detection Float arm pushes valve flap beyond protective bend in upper tube Main valve flap immediately sealed closed by fuel flow Fuel deliverer is notified tank is nearing full by hose jump Fuel reduced to 3-5 GPM through secondary orifice to empty hose

Next Generation Overfill Prevention Valve New Product Launched in 2012 Allows Overflow Valve to be functionally tested without removing from the ground: Simple test avoids an hour of removal and reinstallation time for 2 contractors Eliminates opportunity to damage float mechanism and critical seals for vapor tightness EVR Approved Testable Overfill Valve Test in 60 seconds vs. 60 minutes per tank! Lift Float with Cable to Simulate Fill Validate Proper Poppet Operation Loosen Test Plug

How 71SO Testable Functions User snaps ¼” socket extension into test plug adaptor Lifting the test plug adapter engages cable that is attached directly to bonded float bracket Bonded float bracket engages valve poppet mechanism to close User verifies valve function by visually seeing poppet close through inside of the tube while lifting test plug adaptor with socket extension 4 2 3

Measurement of Shutoff Point OPW Provides Measurement Calculations and Instructions in our Installation Manual to determine the shut off position of the Overfill Valve without removal from the tank

Frequently Asked Questions Does the Test Plug interfere with the Jack Screw assembly? Answer: No, the test port is designed to fit between the lugs of the Jack Screws without any interference Is a special tool required to perform the functional test? Answer: No, the 71SO Testable is designed to be easily tested by anyone with a ¼” socket extension Will the test cable corrode in the aggressive environments within the tank risers? Answer: No, the 71SO Testable utilizes a 300 Series Stainless Steel Cable that does not corrode.

Frequently Asked Questions Can the test cable break? Answer: No, the test cable is extremely strong (>70 lbs tensile strength). Does the test cable pull on the float or the bracket? The float is molded over and through the bracket that the cable is attached to, so this is fused as a single piece. It takes several hundred pounds of force to separate the bracket from the float What happens if the float arm bracket is detached from the overfill valve in the tank? Answer: If the float arm is not attached to the valve inside the tank, pulling on the test plug will lift the float, but not activate the valve. The validation test of viewing the valve not closing from inside of the tube will demonstrate that there is an issue with the valve that must be addressed