Totally Endoscopic Mitral Valve Repair

Slides:



Advertisements
Similar presentations
Mitral Valve Repair  A. Marc Gillinov, Delos M. Cosgrove 
Advertisements

Shunji Sano, MD, Kozo Ishino, MD, Masaaki Kawada, MD, Osami Honjo, MD 
Ablation of Atrial Fibrillation with Concomitant Surgery
Benjamin B. Peeler, MD, Irving L. Kron, MD 
Ischemic Mitral Regurgitation: Chordal-Sparing Mitral Valve Replacement  Tirone E. David, MD  Operative Techniques in Thoracic and Cardiovascular Surgery 
Left and Right Ventricular Assist With the Bio-Medicus Centrifugal Pump  Nevin M. Katz  Operative Techniques in Thoracic and Cardiovascular Surgery  Volume.
Robotic and Minimally Invasive Cardiac Surgery
Eugene A. Grossi, Greg Ribakove, Aubrey C. Galloway, Stephen B. Colvin 
Cardiac Autotransplantation
The Syncardia Total Artificial Heart: Implantation Technique
Total Artificial Heart Replacement With 2 Centrifugal Blood Pumps
Port-Access Approach for Minimally Invasive Mitral Valve Surgery
Andrew Clarke, Graham R. Nunn, Ian A. Nicholson 
Nicola Viola, MD, Christopher A. Caldarone, MD 
Operative Incisions for Minimally Invasive Cardiac Surgery
Port-Access Multivessel Coronary Artery Bypass Grafting
Endoscopic Mitral Valve Repair
Robotic and Minimally Invasive Cardiac Surgery
Ablation of Atrial Fibrillation with Concomitant Surgery
Pacopexy: Restoration Procedure for Nonischemic Dilated Cardiomyopathy
Ischemic Mitral Regurgitation: Chordal-Sparing Mitral Valve Replacement  Tirone E. David, MD  Operative Techniques in Thoracic and Cardiovascular Surgery 
Transventricular Repair of Tetralogy of Fallot
Shunji Sano, MD, Kozo Ishino, MD, Masaaki Kawada, MD, Osami Honjo, MD 
Surgical Correction of Congenital Supravalvular Aortic Stenosis
Aortic Valve Replacement with Pulmonary Autograft: Subcoronary and Aortic Root Inclusion Techniques  Tirone E. David, MD  Operative Techniques in Thoracic.
Redo mitral valve repair or replacement through the right chest
DeVega Annuloplasty of the Tricuspid Valve
Tricuspid Valve Repair Technique
The Syncardia Total Artificial Heart: Implantation Technique
Extra-anatomic Bypass Graft for Recurrent Aortic Arch Obstruction
Osami Honjo, MD, PhD, Vivek Rao, MD 
Organ Care System for Heart Procurement and Strategies to Reduce Primary Graft Failure After Heart Transplant  Masaki Tsukashita, MD, PhD, Yoshifumi Naka,
Repair of Tetralogy of Fallot with Absent Pulmonary Valve Syndrome
Intuity Elite Valve Implantation Technique
Left and Right Ventricular Assist With the Bio-Medicus Centrifugal Pump  Nevin M. Katz  Operative Techniques in Thoracic and Cardiovascular Surgery  Volume.
Repair of complete atrioventricular septal defects “single patch” technique  Fred A. Crawford, MD  Operative Techniques in Thoracic and Cardiovascular.
Ram Sharony, Eugene A. Grossi, Paul C. Saunders, Aubrey C
Anatomic Repair of Recurrent Aortic Arch Obstruction
Fenestrated Fontan for Hypoplastic Left Heart Syndrome
Mitral valve replacement after late failure of mitral valve repair
Parasternal Approach for Minimally Invasive Aortic Valve Surgery
Repair Techniques for Ischemic Mitral Regurgitation
Minimally Invasive Aortic Valve Replacement
Minimally Invasive Aortic and Mitral Valve Operation
Benjamin B. Peeler, MD, Irving L. Kron, MD 
Remodeling the Aortic Root and Preservation of the Native Aortic Valve
Tricuspid Valve Replacement
Idiopathic Hypertrophic Subaortic Septal Obstruction: Robotic Transatrial and Transmitral Ventricular Septal Resection  W. Randolph Chitwood, MD, FACS,
Implantation of the Jarvik 2000 Heart
Mitral Valve Repair  A. Marc Gillinov, Delos M. Cosgrove 
Repair of primum ASD with cleft mitral valve
Aortic Root Enlargement in the Adult
Transatrial Repair of Tetralogy of Fallot
Absent Pulmonary Valve Repair
David W. Pantino, MD, Zain Khalpey, MD, PhD, FACS 
Hemi-Fontan Procedure
Endocarditis with Involvement of the Aorto-Mitral Curtain
Partial Sternotomy for Aortic Valve Operations
Mitral Valve Replacement With Homograft
Chordal Preservation in Mitral Valve Replacement
Transatrial and transmitral myectomy for hypertrophic obstructive cardiomyopathy of the left ventricle  Hikaru Matsuda, MD  Operative Techniques in Thoracic.
Thoracoscopic Approach to Patent Ductus Arteriosus
Ram Sharony, Eugene A. Grossi, Paul C. Saunders, Aubrey C
David Heimansohn, MD, Sina Moainie, MD 
Partial Sternotomy for Mitral Valve Operations
Stage I—The Philadelphia Approach
Total Artificial Heart Replacement With 2 Centrifugal Blood Pumps
Tricuspid Valve Repair for Functional Tricuspid Regurgitation
Chordal Replacement With Expanded Polytetrafluoroethylene Sutures in Mitral Valve Repair  Tirone E. David  Operative Techniques in Thoracic and Cardiovascular.
Repair of Infracardiac Total Anomalous Pulmonary Venous Return
Presentation transcript:

Totally Endoscopic Mitral Valve Repair Bradley S. Taylor, MD, MPH, Hugo K. Vanermen, MD  Operative Techniques in Thoracic and Cardiovascular Surgery  Volume 12, Issue 4, Pages 226-234 (December 2007) DOI: 10.1053/j.optechstcvs.2007.10.003 Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 1 Patient positioning. Patients are placed supine on the operating table with an inflatable bladder to slightly elevate the right hemi-thorax. The right arm is slightly flexed. The anesthesiologist places a central venous line, a right radial arterial line, a double-lumen endotracheal tube, a temperature probe, and a transesophageal echocardiography (TEE) probe. In addition, a 14, 17 or 21 Fr venous cannula is placed in the right jugular vein before preparing the patient and initiating the operation. It will invariably ensure excellent venous drainage and allow for entering the right atrium, which cannot be achieved with a double-stage femoral cannula alone. Right radial artery pressures are monitored throughout the procedure to assess for EndoClamp balloon migration. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 2 Preparation of the groin for CPB. Once the patient has been prepped and draped, a 2- to 3-cm incision is made at the level of the superior femoral triangle. Exposure of the anterior surface of the right femoral artery and vein is conducted. Transmural, longitudinal “U” stitches with 4-0 Gore-Tex (W.L. Gore & Associates, Inc, Flagstaff, AZ) with Teflon pledgets are placed on the artery and two 4-mm purse-strings on the vein are marked for easy identification. During this time, the scrub nurse and perfusionist prepare the EndoClamp and bypass cannulas. a. = artery; v. = vein. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 3 Preparation of the right hemi-thorax and the working port. A 5-cm incision is performed in the inframammary groove and the intercostal space is entered. Next, a 7-mm port is placed two to three intercostal spaces caudal to the right mini-thoracotomy for CO2 administration and a vent line. The 5-mm 0-degree thoracoscope is placed in the same interspace as the thoracotomy at the level of the anterior axillary line. Medially, a 2-mm cut-down is made parasternally for placement of the left atrial retractor. A steel-wire is introduced through the superior chest wall to facilitate exposure of the valve after placement of the anterolateral annuloplasty sutures. Finally, a retraction suture is placed through the central tendon of the diaphragm and pulled through the inferior chest wall to complete the thoracoscopic field. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 4 (A) Peripheral cannulation and placement of the EndoClamp. Once the patient is adequately anticoagulated (ACT > 400), the femoral vein is punctured with a 21-G needle. The Seldinger technique is used to place a guide-wire into the right atrium under TEE guidance. (B) A 25-Fr venous cannula is advanced over the wire with its dilators and is positioned at the junction of the right atrial inferior vena cava junction. Similarly, the femoral artery is punctured and a guide-wire is placed into the descending aorta under TEE guidance. The artery is dilated and a 21- to 23-Fr arterial cannula is placed and secured. The EndoClamp is inserted via the hemostatic valve of the arterial cannula into the ascending aorta under TEE control. CPB is initiated and the venous drainage is confirmed thoracoscopically. Once on bypass, the pericardium can be opened safely and exposure of the atrium can be obtained. If necessary, control of the inferior and superior cavae can be performed at this point in the operation. a. = artery; v. = vein. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 5 (A) Initiation of CPB and Endoballoon Clamping. (Lower left) Upon initiation of CPB, confirmation of SVC and IVC cannulae placement and complete drainage of the right side of the heart must be obtained. Next, the EndoClamp balloon is directed up the descending thoracic aorta and passed around the arch of the aorta to the Sino-tubular junction under TEE direction (upper images). Inflation of the EndoClamp balloon results in occlusion of the ascending aorta and provides the ability to deliver antegrade cardioplegia. The balloon’s position is governed by the counter-forces of the CPB flow versus tension on the balloon line which is locked against the arterial inflow cannulae (lower right). It is not associated with radial forces of the balloon against the aortic wall. (B) Deployment of the EndoClamp and delivery of cardioplegia. Under TEE guidance, the EndoClamp balloon is partially inflated to 75% of the volume of the ascending aorta. This is followed by the injection of 0.25 mg/kg Adenosine via the cardioplegia line portion of the EndoClamp balloon to arrest the heart. The balloon is then inflated to occlude the ascending aorta completely and antegrade cardioplegia is delivered into the root. The balloon is positioned in the mid-portion of the ascending aorta between the sinotubular ridge and origin of the innominate artery. TEE visualization and pressure monitoring of the right radial artery confirm adequacy of placement. Loss of right radial artery pressure indicates that the EndoClamp balloon has migrated cranially and is obstructing the innominate arteries as well as blood flow to the brain. CVP = central venous pressure; IVC = inferior vena cava; SVC = superior vena cava; v. = vein. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 5 (A) Initiation of CPB and Endoballoon Clamping. (Lower left) Upon initiation of CPB, confirmation of SVC and IVC cannulae placement and complete drainage of the right side of the heart must be obtained. Next, the EndoClamp balloon is directed up the descending thoracic aorta and passed around the arch of the aorta to the Sino-tubular junction under TEE direction (upper images). Inflation of the EndoClamp balloon results in occlusion of the ascending aorta and provides the ability to deliver antegrade cardioplegia. The balloon’s position is governed by the counter-forces of the CPB flow versus tension on the balloon line which is locked against the arterial inflow cannulae (lower right). It is not associated with radial forces of the balloon against the aortic wall. (B) Deployment of the EndoClamp and delivery of cardioplegia. Under TEE guidance, the EndoClamp balloon is partially inflated to 75% of the volume of the ascending aorta. This is followed by the injection of 0.25 mg/kg Adenosine via the cardioplegia line portion of the EndoClamp balloon to arrest the heart. The balloon is then inflated to occlude the ascending aorta completely and antegrade cardioplegia is delivered into the root. The balloon is positioned in the mid-portion of the ascending aorta between the sinotubular ridge and origin of the innominate artery. TEE visualization and pressure monitoring of the right radial artery confirm adequacy of placement. Loss of right radial artery pressure indicates that the EndoClamp balloon has migrated cranially and is obstructing the innominate arteries as well as blood flow to the brain. CVP = central venous pressure; IVC = inferior vena cava; SVC = superior vena cava; v. = vein. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 6 Exposure of the mitral valve and placement of the annular sutures. Now, visualization is best accomplished with a 30-degree scope. (A) The left atrium is opened 3 mm medial to the insertion of the pulmonary veins. (B) The left atrial retractor is placed to allow complete exposure of the mitral valve. 2-0 polyester sutures are placed in the annulus of the mitral valve and brought through the working port. (C) We recommend placing the anterolateral commissural sutures first since this is the region with the risk of EndoClamp balloon perforation. (D) After the first four sutures are placed, they are retracted using the steel wire previously placed through the superior aspect of the chest. These sutures are placed under adequate tension to assist in the exposure. Examination of the mitral valve apparatus and left atrium is thoroughly conducted to evaluate for prolapse. Evidence of a jet lesion indicates prolapse of the opposing leaflet. The mitral annulus is evaluated for dilation and is measured at this time. Leaflet pliability and prolapse are also assessed. Distending the ventricle assesses retraction of the mid portion of the anterior leaflet by secondary chordae. The remaining annular sutures are then placed. IVC = inferior vena cava; SVC = superior vena cava. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 7 Trapezoidal resection of P2. P2 is visualized and resected while preserving chordae tendinae of normal height adjacent to the prolapsed segment. Care must be taken not to resect too much tissue. The goal is to leave enough tissue to create a coaptation surface of 1.0 cm. If necessary, a sliding plasty can be performed by creating two transverse incisions along the annulus. Sutures are then placed taking correspondingly larger amounts of tissue along the annulus and smaller amounts of tissue on the leaflet edges. The two leaflet edges should meet and are ready to be reapproximated. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 8 Reconstruction of the posterior leaflet. The resected segment of P2 is reapproximated with a running 4-0 polypropylene suture. The knot is tied at the level of the annulus and can be hidden below the ring once it is placed. Additional techniques can also be performed such as chordal shortening, chordal transfer, or the placement of Gore-Tex chordae. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions

Figure 9 Placement of the annuloplasty ring. Annular sutures are brought through the sewing ring in their corresponding position. Next, the ring is slid down to the annulus and the sutures are tied using a knot pusher. Performing a saline test confirms the competency and symmetry of the repair. Concomitant atrial ablation can be easily performed before closure of the left atrium. Once the atrium is repaired, a pacing wire is placed on the inferior wall of the left ventricle before deflating the EndoClamp balloon. De-airing and separation from bypass are performed in the usual fashion. Once off bypass, the femoral cannulae can be removed and the incisions are closed. Operative Techniques in Thoracic and Cardiovascular Surgery 2007 12, 226-234DOI: (10.1053/j.optechstcvs.2007.10.003) Copyright © 2007 Elsevier Inc. Terms and Conditions