Update on ASTM and Standard Methods method development activities

Slides:



Advertisements
Similar presentations
Radiochemical Methods and Data Evaluation
Advertisements

Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
Quality is a Lousy Idea-
Validation of screening methods (2002/657/EC)
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
Mentoring Session Technical Assistance Committee Method Modifications.
QA/QC Considerations for Sampling and Analysis Associated with EPA Method 1631 Chuck Wibby Wibby Environmental Seminar on Low Level Mercury Data and Analyses.
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Field Analysis Quality Control
Validation of Analytical Method
Debra Waller NJDEP-Office of Quality Assurance
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
Perchlorate Analysis by Ion Chromatography The CA DHS Protocol H.S. Okamoto, D.K. Rishi and S.K. Perera.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek – Applications Chemist.
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
QA/QC and QUALIFIERS LOU ANN FISHER CITY OF STILLWATER, OK
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
Laboratory Certification Update Part 2 Common Findings KWWOA Louisville April 15, 2015 Presented by Frank Hall, Laboratory Certification Coordinator.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
William Telliard U.S. EPA Office of Science and Technology
Providing comprehensive scientific resources to environmental clients worldwide. Dissolved Gas Analysis: A Review and Comparison.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Achieving Method Compliance with Innovative Technologies Tony Francis, PhD Principal, SAW Environmental TCEQ – Environmental Trade.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
EQUIPMENT and METHOD VALIDATION
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Method Validation-where do I start?
Overview CWA Methods Update Rule Method 608.3
The Method Update Rule Does this affect me? HOW?
Determination of TKN by Subtraction using ASTM D and ASTM D
Quality is a Lousy Idea-
Clean Water Act Methods Overview of EPA’s CWA Method Activities
Method Modifications & ATP 40 CFR part and 136.5
Overview of EPA Method 1631, Revision E By Roy W
World Health Organization
EPA Method A Summary of the Changes in the Newly Promulgated GC/MS Method for Volatile Organics in Wastewater Harry McCarty and Kevin Roberts CSRA,
EPA Method Equivalency
New Method for Analysis of Total Nitrogen
Added Monrovia and South Bend to the slide.
Added Monrovia and South Bend to the slide.
Why we need new Total Nitrogen parameter and methods for CWA reporting
The Analysis of Soils and Waters in Accordance with U. S
Have Instrument, make method; How new methods are made and validated
Quality is a Lousy Idea-
EPA Method Equivalency
EPA Region 10 Alternate Test Procedures and Method Update Rule
Analytical Method Validation
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Chapter 5 Quality Assurance and Calibration Methods
Why Use Them? By: Marcy Bolek – Alloway
SDWA Collaborative Efforts Overview
ANALYTICAL METHOD VALIDATION
World Health Organization
National Environmental Monitoring Conference
NJ DWQI Testing Subcommittee
Introduction to Analytical Chemistry
TCEQ Environmental Trade Fair Water Quality Division
Andy Eaton, PhD, BCES Technical Director Joint Editorial Board-Chair
2019 AWOP National Meeting Office of Ground Water and Drinking Water
Presentation transcript:

Update on ASTM and Standard Methods method development activities Added Monrovia and South Bend to the slide. William Lipps, Eurofins Eaton Analytical Monrovia South Bend

Full Service Laboratories Centers of Excellence Eurofins Lancaster Laboratories Env. Lancaster, PA Eurofins Calscience Garden Grove, CA Eurofins Spectrum Analytical Agawam, MA North Kingstown, RI Centers of Excellence Eurofins Air Toxics Folsom, CA Eurofins Eaton Analytical Monrovia, CA South Bend, IN Eurofins Frontier Global Sciences Bothell, WA Eurofins QC Southampton, PA www.EurofinsUS.com/Env

SM And ASTM - Voluntary Consensus Standard Development Organizations (SDO) AKA – VCSB Standard Method = A method of known and demonstrated precision issued by a SDO Standard Reference Method = A Standard Method with demonstrated accuracy Reference = John K. Taylor, Quality Assurance of Chemical Measurements, Lewis Publishers, 1987

New Guides To Task Groups To Gather All Information Needed During Method Development “In accordance with the National Technology Transfer and Advancement Act (NTTAA), EPA considers Voluntary Consensus Standards Bodies (VCSB), such as Standard Methods and ASTM in regulatory actions when periodically updating the list of approved methods.” The new Validation Procedures will provide guidelines to method developers as to information EPA needs so that ASTM and/or Standard Methods can easily submit new, and updated methods for use in wastewater, drinking water, and RCRA compliance

Methods We Develop And / Or “Validate” Method already exists Modification of existing method New method for existing analyte New method and new analyte

Method Already Exists This “validation” is what a lab does MDL LCMRL IDAC Spikes Duplicates Lab compares performance to criteria in existing method This type of method validation is NOT what ASTM or SM does

Modification Of An Existing Method Method needs modification SDWA ATP Limited Validation VCSB CWA Part 136.6 In lab you can modify a method and keep data on file, at VCSB a technical modification requires new data and balloting, editorial requires balloting. Red Line, reason for change, and possible two column comparison to EPA

Examples Of Modifying An Existing Consensus Standard MDL incorrect, or newer MDL needed Create task group Collect data, verify at several locations over several days Break method, re-verify Modify text, ballot at task group and main committee Incorrect reagent recipe Historical data search Editorial  SM can make change, ASTM re-ballot Not editorial  collect data, and re-ballot Convert manual method to automated method This is a new method for VCSB

New method for existing analyte New Method For An Existing Analyte New method for existing analyte SDWA ATP New VCSB method CWA VCSB require task group, single and multiple lab “validation”, balloting. Validation plan and full data package submitted to EPA

Examples Of New Method For Existing Parameter There is already a SDWA, CWA, or “RCRA” parameter  new method is: Different extraction / digestion Different determination step This requires: Task group Rationale Extensive Single lab study Single operator precision and accuracy Comparison with existing method(s) Ruggedness Multiple laboratory study Reproducibility between labs Validation plan and data package

Rationale  Why Do We Need A New Method For An Existing Parameter? Lower detection limits Better precision Better recovery Fewer interferences Less waste (time, reagents, hazardous waste) Fewer chemicals/steps Reduce solvent use Improve safety

Single Lab Study Of A New Method For An Existing Parameter Establishes: Selectivity  prove new method measures what it says it measures Calibration/Standardization technique  required curve fitting or standardization protocols Reagent recipes, preparation, containers, shelf life (if different) Holding time and preservation (if different) Quantitation limit and range Applicable matrices (if different) Comparison to existing method MDL, ML, and calibration range Repeatability on standard solutions Bias using reference materials RM if available Spiked matrices (if possible) Ruggedness

Single Lab Study Of Precision And Bias Spiking Multiple Matrices At 3 Concentrations

Analysis by Cd Reduction Single Lab Study Comparing Two Methods Analysis by Cd Reduction (mg NO3+NO2-N/L) Analysis by Reductase 0.96 0.94 0.04 0.05 0.32 0.24 0.68 10.1 11.6 0.75 0.79 2.5 3.11

Single Lab Study Comparing Two Methods Using Youden Plot

What is ruggedness, and how to test for it? What steps are so critical that changing them changes the result? Factor Nominal Variation Portion size 10 ml 25 ml Evaporation temperature 160 °C 220 °C Evaporation time 1 hour 30 minutes Digestion temperature 370 °C 380 °C Digestion time 15 minutes

Once All Other Tests Are Completed You Conduct A Multiple Laboratory Study: Establish reproducibility of method between laboratories

Precision And Bias Report With Youden Pairs: Number of useable pairs 6 7 True Concentration (mg/L) 50.1 40.1 Mean Concentration (mg/L) 3.88 3.31 8.29 9.63 49.8 40.2 % Recovery 99.4 100 Overall Standard Deviation 0.34 0.56 1.19 1.36 4.28 3.18 Overall % RSD 8.78 16.2 14.2 14.0 8.60 7.90 Number of Useable Pairs Single Operator Standard Deviation 0.37 0.59 1.32 Single Operator % RSD 10.2 6.58 2.94

Precision And Bias Report With Blind Duplicates: Matrix 5 6 7 8 9 12 Number of useable values 14 True concentration (mg/L) 5.39 N/A 21.0 0.501 Mean Recovery (mg/L) 5.67 1.61 1.68 21.9 3.63 0.808 % Recovery 105 104 161 Overall Standard Deviation, St 0.777 0.265 0.350 2.53 0.374 0.162 Overall Relative Standard Deviation (%) 13.71 16.48 20.99 11.54 10.28 20.02 Single Operator Standard Deviation So 0.549 0.243 0.329 1.156 0.317 0.150 Single Operator Relative Standard Deviation (%) 9.68 15.47 19.75 5.27 8.71 18.59

New method for existing analyte New Method For A New Analyte New method for existing analyte SDWA New VCSB method CWA VCSB require task group, single and multiple lab “validation”, balloting. Validation plan and full data package submitted to EPA

Examples Of New Method For Existing Parameter There is not a SDWA, CWA, or RCRA parameter  new method is: Maybe reported in literature Maybe a technique used, but not formalized This requires: Task group & rationale More extensive Single lab study than previous Single to several lab operator precision and accuracy Extensive evaluation of interferences Lots of “optimization”: operation, extractions, digestions Ruggedness Multiple laboratory study Reproducibility between labs Validation plan and data package

Rationale  Why Do We Need A New Method? Is there a demand or need to analyze compound X? How will we test for it? Is this the best way? How low, or at what concentrations? What matrices? Who are the stakeholders? Do any other countries do this test?

Single Lab Study Of A New Method Establishes: Selectivity  prove new method measures what it says it measures Calibration/Standardization technique  required curve fitting or standardization protocols Reagent recipes, preparation, containers, shelf life Holding time and preservation Quantitation limit and range Applicable matrices Interferences and mitigation MDL, ML, and calibration range Repeatability on standard solutions Bias using reference materials RM if available Spiked matrices (if possible) Ruggedness

Once All Other Tests Are Completed You Conduct A Multiple Laboratory Study: Establish reproducibility or lack of reproducibility between laboratories

Conclusion: Brief overview of approach Both SM and ASTM guide in draft form Working with EPA to standardize guides Guide to create consistency between task groups As always, steps vary

Eurofins Eaton Analytical, LLC CALIFORNIA CECs Any Questions? William Lipps williamlipps@eurofinsus.com Eurofins Eaton Analytical, LLC www.eurofinsus.com

Thank You!