IS CAN Bus – CiA WD 103 Update

Slides:



Advertisements
Similar presentations
© 2006 Swagelok Company. IS CAN Bus – CiA DSP 103 V 1.0 Low Cost, Intrinsically Safe Transducer Bus Enabling NeSSI Gen II Rick Ales Swagelok Company.
Advertisements

Why to learn OSI reference Model? The answer is too simple that It tells us that how communication takes place between computers on internet but how??
OSI MODEL Maninder Kaur
© 2006 Swagelok Company. Swagelok confidential. For internal use only. IS CAN Bus – CiA WD 103 Update Low Cost, Intrinsically Safe Transducer Bus Enabling.
1 Chapter 9 Computer Networks. 2 Chapter Topics OSI network layers Network Topology Media access control Addressing and routing Network hardware Network.
CPAC Communications Session PITTCON 2001, March 5 - 8, 2001 Rick Ales Swagelok Solon, Ohio.
© 2006 Swagelok Company. IS CAN Bus – CiA WD 103 Update Low Cost, Intrinsically Safe Transducer Bus Enabling NeSSI Gen II Rick Ales and Doug Nordstrom.
I²C Bus Development An Implementation of the Generation 2 Bus Siemens Activities Silke Ebbing, March 2007.
OSI Model MIS 416 – Module II Spring 2002 Networking and Computer Security.
1-1 Introduction to Computer Networks and Data Communications.
Open System Interconnection (OSI) Model
© Swagelok Company, 2002 Rick Ales 4/21/2003 Evolution of NeSSI Gen III Circa 200? Miniature/Modular (enabled by Mechanical Standard) Smart Devices (enabled.
OSI Model 7 Layers 7. Application Layer 6. Presentation Layer
The CT76 Solutions Package: Patrick Lowery, CPAC Fall Meeting
NeSSI Update An Implementation of the Generation 2 Bus Siemens Activities November 2006.
Chapter 8 COMMUNICATION AND COMPUTER NETWORK
LECTURE 2 CT1303 LAN. STANDARD MODELS: OSI Model : Open system Interconnection. is a conceptual model that characterizes and standardizes the internal.
CHAPTER 3 1. THE OSI MODEL AND THE TCP/IP PROTOCOL SUITE  Outline: 1. Protocol Layers 2. OSI Model 3. TCP/IP Model 4. Addressing 2.
OSI Model. Open Systems Interconnection (OSI) is a set of internationally recognized, non-proprietary standards for networking and for operating system.
The OSI Model and the TCP/IP Protocol Suite
Computers in Surveying SVY2301 / E4006 Automated Surveying.
LECTURE 9 CT1303 LAN. LAN DEVICES Network: Nodes: Service units: PC Interface processing Modules: it doesn’t generate data, but just it process it and.
Fieldbus 1 FISCO. Fieldbus Certified Transmitter : Intrinsically safe IIC/Group A T4 Ui : 30V Ii : 100mA Ci : 0.01  F Li : 100  H C c : 0.12  F L c.
Jiří Novák, CTU FEE in Prague, Dept. of Measurement Industrial Distributed Systems Technology overview Technology overview Important features Important.
© 2008 Swagelok Company. IS CAN Bus – CiA DSP 103 V 1.0 Low Cost, Intrinsically Safe Transducer Bus Enabling NeSSI Gen II Rick Ales Swagelok Company IFPAC.
OSI Model. Topics What is the OSI Model? What is a Protocol? Why 7 Layers? The 7 Layers – Application – Presentation – Session – Transport – Network –
Protocols Rules governing the communication process, the language of the deal between the devices, must reflect Layers protocols define format, order of.
Rehab AlFallaj.  OSI Model : Open system Interconnection.  is a conceptual model that characterizes and standardizes the internal functions of a communication.
Intelligent NeSSI Sampling Systems – Feasible and Practical Rick Ales and Dave Simko Swagelok Company IFPAC 2006.
Computer Networks Syed Md. Ashraful Karim Lecturer, CSE BU.
Rehab AlFallaj.  Network:  Nodes: Service units: PC Interface processing Modules: it doesn’t generate data, but just it process it and do specific task.
OSI Model. Open Systems Interconnection (OSI) is a set of internationally recognized, non proprietary standards for networking and for operating system.
TCP/IP Protocol Suite Suresh Kr Sharma 1 The OSI Model and the TCP/IP Protocol Suite Established in 1947, the International Standards Organization (ISO)
CHAPTER -II NETWORKING COMPONENTS CPIS 371 Computer Network 1 (Updated on 3/11/2013)
© Swagelok Company, 2004 IEEE P Project Overview and Progress Report CPAC May 2005 by Rick Ales Updated by John Mosher.
Page 1 NeSSI II - A Platform for Micro-Analytical Devices Sensor Actuator Manager (SAM) Controller Considerations And Specification Identification CPAC.
Network types Point-to-Point (Direct) Connection Dedicated circuit boards connected by cable; To transfer data from A to B: – A writes on its circuit board;
NeSSI-bus History, Evolution and Selection for Process Analytical CPAC, Seattle, WA, USA November 10, 2005 “the best way to predict the future is to create.
Industrial communication networks
Local Area Networks Honolulu Community College
Programmable Logic Controllers: I/O
THE OSI MODEL By: Omari Dasent.
Networking Devices.
Chapter 3 Computer Networking Hardware
Swagelok confidential. For internal use only.
Chap. 2 Network Models.
Connecting LANs, Backbone Networks
Chapter 3.
How SCADA Systems Work?.
LAN Risanuri Hidayat.
CT1303 LAN Rehab AlFallaj.
Understanding the OSI Reference Model
CT1303 LAN Rehab AlFallaj.
Chapter 3.
SWITCHING Switched Network Circuit-Switched Network Datagram Networks
NET301 Lecture 2 10/9/2015 NET 301.
Layer 1 of the TCP/IP protocol stack: Network Access Layer (NAL)
Chapter 3: Open Systems Interconnection (OSI) Model
Ethernet LAN 1 1.
Network Protocol Layers
Korbin Blunck November 19,2012
Computer Networks.
Day 2 Training - Technical
Chapter One Introduction to Computer Networks and Data Communications
OSI Reference Model Unit II
1.2.1 Data transmission.
OSI Model 7 Layers 7. Application Layer 6. Presentation Layer
Serial Communications
FieldLink Process Networking Introduction
Unit – III Network Essentials
Presentation transcript:

IS CAN Bus – CiA WD 103 Update Low Cost, Intrinsically Safe Transducer Bus Enabling NeSSI Gen II Rick Ales Swagelok Company © 2006 Swagelok Company.

MPC Gen II Architecture Ethernet Remote Operator Station Analyzer Hazardous Area Class 1 Div 1 (Zone 1) THE NeSSI BUS CONUNDRUM On the surface, choosing an open standard IS transducer bus seems to be a simple choice of one of four possible protocols: FOUNDATION fieldbus™, PROFIBUS PA, HART®, or ControlNet™. However, the NeSSI consortium discovered that none of these buses was particularly well suited for the types of smart devices that would populate a NeSSI Gen II system. The consortium had concerns about the architecture, size and cost of these options. Architecturally, the IS buses do not match the simple design of NeSSI devices. Typically, the IS buses are designed to operate a few sophisticated devices in a complex messaging format over long distances (i.e., 1.9 km for FOUNDATION fieldbus). However, NeSSI Gen II components are simple sensors and actuators that support basic configuration and diagnostic functions, thereby requiring a less complex communications format. Further, the NeSSI devices communicate with a local controller typically located less than 10 meters away. On the size front, the 1½-inch square ANSI/ISA 76.00.02 footprint places a serious constraint on the amount of electronics that can be fitted onboard a NeSSI Gen II device. The major IS buses, with the exception of HART, require at a minimum: a relatively powerful microcontroller, a protocol controller ASIC (Application Specific Integrated Circuit), a bus interface, and driver circuits. The size and number of required electrical components makes it difficult, at best, to squeeze an IS bus – along with the requisite input/output (I/O) circuitry, connectors and other miscellaneous electronics – into the NeSSI footprint. Lastly, the relative cost of IS buses compared to NeSSI devices is high. The IS buses were designed to be deployed in larger process control valves and transmitters in which the bus technology represents a fraction of the device’s total cost. NeSSI devices typically cost much less than larger process control valves or transmitters, making the cost of a smart NeSSI device that uses one of the IS bus technologies much higher than its non-networked counterpart. Industries not using process analytics, such as semiconductor, consumer electronics and automotive, use simpler, smaller and less expensive buses like USB and CAN. However, these options are not intrinsically safe. Given the choices, decision makers are faced with the NeSSI bus conundrum: Do they make one of the IS buses simpler, smaller and less expensive, or do they make one of the simpler, smaller and less expensive buses intrinsically safe? IS NeSSI™ Bus V Flow Sensors P T A NeSSI Device Sample System Sensor Analyzer Manager SAM © 2006 Swagelok Company. Swagelok confidential. For internal use only.

Communications Model Virtual Message Path Actual Message Path The Application layer represents the level at which applications access network services. This layer represents the services that directly support applications such as software for file transfers, database access, and electronic mail. The Data Link layer packages raw bits from the Physical layer into frames (logical, structured packets for data). This layer is responsible for transferring frames from one node to another, without errors. After sending a frame, it waits for an acknowledgment from the receiving computer The Physical layer transmits bits from one computer to another and regulates the transmission of a stream of bits over a physical medium. This layer defines how the cable is attached to the network adapter and what transmission technique is used to send data over the cable. © 2006 Swagelok Company. Swagelok confidential. For internal use only.

IS and the Ignition Curve Intrinsic Safety Intrinsically safe equipment is defined as "equipment and wiring which is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentration." (ISA-RP12.6) This is achieved by limiting the amount of power available to the electrical equipment in the hazardous area to a level below that which will ignite the gases. In order to have a fire or explosion, fuel, oxygen and a source of ignition must be present. An intrinsically safe system assumes the fuel and oxygen is present in the atmosphere, but the system is designed so the electrical energy or thermal energy of a particular instrument loop can never be great enough to cause ignition. Ignition Curve Group A & B = Acetylene + Hydrogen; C= Ethylene; D=Gasoline, Propane IS bussed require 24VDC to achieve kilometer length distances; from ignition cure 24VDC corresponds to 200 ma and accounting for safety factors results in around 2.5 Watts of available power. Relax the distance requirement to meter length distances then the required voltage can be reduced to 10 volts or less which allows current is higher power. A commercial power supply providing up to 4 channels at 9.5 VDC at 1 amp per channel is readily available. © 2006 Swagelok Company. Swagelok confidential. For internal use only.

IS CAN Major Parameters The CAN signaling spec. ISO11898-1,2 & CiA301 Co-cabled 10m max Single power source only 3.3V Transceiver 1/3 the Power Power bus specification P+F RSD2-PSD-EX4.43 M12 or M8 Connectors 2 Power and 2 CAN wires Area Classification Class 1 Div 1 (Zone 1) Entity Parameters VOC (V) ISC (A) Groups CO (uF) LO (uH)   A, B (IIC) (Acetylene & Hydrogen) 0.8 10 9.5Vdc 1.0 A C (IIB) (ethylene) 2.4 40 D (IIA) (propane) 6.4 80 © 2006 Swagelok Company. Swagelok confidential. For internal use only.

IS CAN Physical Layer Topology 4 Circuits 8.5 Watts each © 2006 Swagelok Company. Swagelok confidential. For internal use only.

CiA WD103 Organization Joshua Pearl IXXAT Co. Chairman Reiner Zitzmann CAN in Automation Secretary Swagelok ABB Siemens Texas Instruments Pepperl + Fuchs Turck Parker Hannifin Circor www.smartshs.org Prototype IS CAN system is running at ABB Lewisburg using the following components: P+F Power supply TI 3.3V transceiver and 2407 DSP evaluation systems IXXAT isolated repeater Current Draft standards has been submitted to CiA for distribution for comment. © 2006 Swagelok Company. Swagelok confidential. For internal use only.

Discussion? © 2006 Swagelok Company. Swagelok confidential. For internal use only.