Power Systems Protection Test Equipment

Slides:



Advertisements
Similar presentations
Distributed Intelligence Provides Self-Healing for the Grid
Advertisements

DOD Microgrids The Missing Link: Microgrid Applications Michael Dempsey P.E. Burns & McDonnell June 12, 2013 © 2013 Burns & McDonnell. All Rights Reserved.
CIRCUIT BREAKER FIRST TRIP TESTING Michael McCraney.
Prepared by Kazi Md. Shahiduzzaman Circuit Breker.
1 Team BUSS Backup Storage Source. 2 Team BUSS Backup Storage Source EHV Substation Second DC Storage Source Sponsor Idaho Power Company Team Members.
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
1 PCA2 On-load Protection Condition Analyser. 2 PCA2 online testing concept Concept introduction: PCA2 is a new system test approach intended to save.
© 2011 Ericson Manufacturing, Willoughby, Ohio
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
3200A Electrical Test Equipment Calibrator. Automatic Loop Correction To simplify calibration of loop testers, the 3200A can be fitted with the Auto.
Chapter 7 SYSTEM PROTECTION
Workflow Based Tools Simplifying All Job Functions.
Lesson 9: Electrical Components
Texas Integrated Energy Solutions. Development Team, Background, Objective, & Justification 2.
Presenter: Peter Busch
ea technology Effective Condition Assessment of MV Switchgear
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
ISA CIRCUIT BREAKERS TEST SETS
Electricity in the Home CBE. Wiring a plug DC and AC DC stands for “Direct Current” – the current only flows in one direction: AC stands for “Alternating.
NERC Lessons Learned Summary LLs Published in September 2015.
1 of 25 © 2007 Ideal Industries Power Quality At the Plug IDEAL INDUSTRIES Author: Patrick Elliott Application Guide to Power Quality.
Preventing Voltage Sags and Interruptions. # Equipment supplier awareness: # Customers level protection: # Utility level protection: - Sag magnitude and.
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
AC Current An AC circuit consists of a combination of circuit elements and an AC generator or source The output of an AC generator is sinusoidal and varies.
AUTOMATIC CIRCUIT RECLOSER
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Electrical Current & Circuits. Components of an electrical circuit Source of electrical energy (battery) A conductor of electrical energy (wire) Device.
Protection of Power Systems
SEMINAR PRESENTATIon ON C IRCUIT B REAKER DEPT. OF ELECTRICAL ENGG. JALPAIGURI GOVT. ENGG. COLLEGE PRESENTED BY Madhusudan Mahato Malay Ghosh.
Install protection equipment
Test and Interpretation of Test Results
Sub Station.
Protection of Power Systems
G-scan PC Utility Viewer Manual
Operating gear switch pursuant to its operational function
Protection Relay Testing
Interconnect Protection of Dispersed Generators
Electrical Circuits.
3AH5 Vacuum Circuit-Breaker For Standard Applications
SCADA for Remote Industrial Plant
PRC Implementation Plan and Summary of Devices
GROUND-FAULT GROUND-CHECK MONITOR
Presented by: LADWP November 14, 2017
EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR
Circuit Breakers & Reclosers
Office 365 September 07, 2016.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Chapter 7 System Protection
swingo XP Firmware, Service Tool & Error Codes
High Voltage Power Circuit Breakers
Protective Relaying Conference
GEORGIA TECH PROTECTION CONFERENCE 2018
Presented to: IEEE-IAS (Atlanta) Presented by: Michael D. Seal, P.E.
Complex Resistor Combinations
Review of Distribution Network Protection
3AH5 Vacuum Circuit-Breaker For Standard Applications
ENTER OUR FRIEND MR. RELAY
Topic 3: Connecting and Starting Three Phase Induction Motors
Substation Equipment's
Presentation transcript:

Power Systems Protection Test Equipment

PCA2 Protection Condition Analyser

What is it? All-in-one quick tester for Breaker & Protection Can test circuit Online or Offline Provides all data required for CBM / RCM maintenance programs Secondary Current Injection Set with timer

What does it test? Relay Op-Time Breaker Op-Time & Condition (+ reclose) Trip coil current profile Battery Condition, CT & Wiring Integrity ‘Snapshot’ of entire protection & breaker system in actual, live operation

Connections Only 2-wires + clip-on CT Substation wiring not altered No connections broken or removed More connections gives more info No need for test blocks

Connections – In use

Online Testing – Why? Captures critical ‘First Trip’ Minimal Outage Time – can use reclose Protection remains active to point of trip Quick, cost-effective

Online Injection – How? Software based control-loop Feedback from clip-on CT Synchronised to Zero-crossing of load current

Background Developed with EDF Energy UK 1000’s of 11 & 33kV circuits Alternative to manual injection trip-testing Safer Combined test with Relay Op-Time Single instrument Modern, on-site results viewing, printing & archiving

Results Instant oscillographic & numeric display On-screen measurements IEEE COMTRADE format Saved to internal Flash or USB-drive PC display using any COMTRADE viewer Built-in printer

Results Oscillographic Results Numerical Results TRLY: Relay Op time LTCH: Trip latch release time BFFR: Time when TC slug reaches stop ACON: Time the ‘a’ contact interrupts the TC current END: Time when TC current reaches zero MCON: Time of transition of main interrupter contacts IPK1: Amplitude of first current peak IPLT: Max current peak VINI: Initial battery voltage VMIN: Minimum battery voltage

Typical Faults/Impending Faults Identified

Conclusion Single multipurpose instrument Rapid Testing Online test (first trip) Archived test results On-site printout Enables cost-effective CBM / RCM program