Tas Climate Based Daylight Modelling

Slides:



Advertisements
Similar presentations
Recent Practical Applications Using Radiance 2003 Radiance Workshop Matt Franks, Arup Lighting Andrew McNeil, Arup Lighting.
Advertisements

Sustainable Lighting Strategies
16469 Low Energy Building Design Lighting Cameron Johnstone Department of Mechanical Engineering
The Dalles Middle School
PASSIVE ARCHITECTURAL COOLING FOR THREE STOREY OFFICE BUILDING DESIGN CONCEPT RTU Working group: KRISTAPS SAFRANOVS, JURIS SOROKINS, NATALY KUZNECOVA,
Tas seminar/demonstration on Part L 2006 of the Building Regulations Presented by Alan Jones EDSL February
Sustainable Architecture Presented by Caroline Batson Senior Architect and Sustainability Manager.
Homeaboutpartnersnewsdownloads principlesin depthapplicationsteaching resourceslearning resourcesprinciples Natural Lighting One of the aim of daylighting.
The Three Tiered Philosophy
Energy Tax Savers, Inc. Tax Aspects of Daylighting and Solar Shades Presentation.
Direct solar radiation is both a powerful environmental stress & renewable energy resource. The sun’s energy is most concentrated on the roof (spring through.
Natural Light influence in Architecture:
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Green Building Leadership in Energy and Environmental Design (LEED)
BRE Energy Efficient Office of the Future
Homeaboutpartnersnewsdownloads principlesin depthapplicationsteaching resourceslearning resourcesprinciples Natural Lighting Lighting standards Daylighting.
Energy Efficient Glass Façade for building envelope Sri Ram.N – IGBC AP; GRIHA Trainer Saint Gobain Glass India 15 th June 2011.
Aperture Placement & Area. Aperture Refers to any daylight source – Windows – Skylights – Openings – Transparent or translucent surfaces Placement and.
Tools for Integrated Design ID seminar October Christian Hviid Industrial PhD-student Birch & Krogboe.
BAE SYSTEMS DESIGN PROJECT: DAYLIGHTING TECHNIQUES/ AFTERNOON DE-”LIGHT” EDSGN 100 Sec. 6 Team 3: David Young, Robert Vadella, Victoria Rodriguez, Phil.
Windows. Huge variety of available building components and several important roles Thermally most important they admit solar radiation Advantageous in.
WHAT NEEDS TO BE COMMISSIONED IN ZERO ENERGY BUILDINGS 1 What needs to be Commissioned in Zero Energy Buildings? Jorge Torres Coto.
SLIDE 1 | Dantec Dynamics | 2012 A Nova Instruments company DANTEC DYNAMICS ComfortSense application program.
Building Orientation.
PASSIVE SOLAR DESIGN. Design Techniques
Building promoter: PROBAM nv Architect: Declercq E. The Keppekouter project Design issue Design issue Major findings Major findings Keppekouter building.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Evaluation of Building Energy Performance Rating Methods ASHRAE TRP-1286 Initial Results Jason Glazer, P.E. GARD Analytics January 2006.
The Town Hall of Zevenhuizen S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F. Broekhuizen Delft, April 1998 Presentation of the building Presentation of the.
The European Office Building S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F. Broekhuizen Delft, April 1998 S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F.
ARC 810: Building Climatology Department of Architecture, Federal University of Technology, Akure, Nigeria ARC 810: Building Climatology Department of.
Lecture 9: Windows and Daylighting Material prepared by GARD Analytics, Inc. and University of Illinois at Urbana-Champaign under contract to the National.
 Primarily a study in control  Source that does not consume electricity  Connects us with the natural world  Flavors of Daylight  Functional daylight.
LIGHT. The Requirements of good Light Good light is essential for efficient vision. Poor lightening lead to straining and eye fatigue. The following light.
NORTHERN NEW MEXICO COLLEGE SERPA Solar Energy Research Park and Academy Summary: Approx 9,800sf classroom and laboratory building All new construction,
The Renson Headquarters Renovation issue Renovation issue Major findings Major findings The RENSON- The RENSON- Headquarters More information... More information...
Predesign Conceptual Design Design Development Detailed Design & Documentation Construction Operations and Maintenance.
ACOSHAPE Acoustic Lighting Case Study Document. Requirements General school areas such as; meeting rooms, offices, libraries and classrooms have to reach.
The Energy Impact of Daylighting and Your Impact on Building Design Jon McHugh, MSME Heschong Mahone Group ASHRAE/AIA Meeting April 20, 1999.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
CDC Daylighting Analysis PNNL March 07, Methodology Daysim is used to analyze daylighting availability over a year course and glare condition.
Energy Design of Buildings using Thermal Mass Cement Association of Canada July 2006.
Some Pointers for your assignment..  Passive solar heating is defined as using solar energy incident on windows, skylights, greenhouses, clerestories,
Objectives Learn about daylighting Review lighting -terminology -technology -design.
ASSIGNMENT. Luanda, Angola Latitude: 8° 50' 18 S Longitude: 13° 14' 4 E.
Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007.
Barnett/Ziegler/Byleen Finite Mathematics 11e1 Learning Objectives for Section 5.1 Inequalities in Two Variables The student will be able to graph linear.
Renewable Energy Technologies and the Building Schools for the Future Programme Property Group - M&E Team Michael J Rigby M & E Team Manager Mechanical.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: January 14, 2010 The effects of passive heating and cooling on the energy performance.
The number of procedures by type and data about rev/costs. The summary section, includes a change area, which shows the difference between the current.
Announcement: The Course Test is Net week ! On Wednesday, October 12 It starts at 1 pm sharp.
Building Environmental Systems
Solar Energy Aides City Efficiencies and Cost Savings
LIGHTING IMPROVEMENT IN CUTTING STATION
Tas Climate Based Daylight Modelling
Heat gain in buildings: Other factors
Jean Ballet, CEA Saclay GSFC, 31 May 2006 All-sky source search
Conduction Cooling Loads
Daylight measurements and luminance ratio determination
PEPCO Energy here Used there
Climate Based Daylight Modelling
Ann Bodkin Education & Skills Funding Agency Capital Group
Full-Building Radiation Shielding for Climate Control
Chapter 4B: SOLAR IRRADIATION CALCULATION
Carbon: Transformations in Matter and Energy
Integrated Daylight Simulation
Leadership in Energy and Environmental Design (LEED)
Daylight Redirecting Window Film
Objectives Finish Lighting system design Daylighting.
Presentation transcript:

Tas Climate Based Daylight Modelling Climate based daylight modelling originated in the lighting simulation community. Hourly diffuse and direct solar radiation climate data is used to produce daylight coefficients for patches of sky. Irradiance data is converted to illuminance using a luminous efficacy model. The daylight contribution to the space is then calculated hourly through the year for each sky patch. EDSL’s Tas software has originated in the thermal simulation community. Our Tas software calculates the diffuse and direct solar distribution in spaces hourly through the year. We have developed a daylighting simulation engine, which is fully integrated with our thermal simulation engine. We are, therefore, able to calibrate the daylight contribution from the solar contribution in a space using luminous efficacy. Put simply, we convert the hourly solar income into hourly daylight income. The following slides illustrate the functionality of the combined thermal and daylight simulation model on a classroom.

Tas allows specific spaces, from a large model, to be selected for individual analysis. A complete range of analysis may be undertaken on the selected space, or spaces, without having to simulate the whole of the building model. Here a classroom has been selected to produce CBDM metrics and adaptive comfort analysis. The roof has been made transparent in the display to show internal layout.

This image shows the direct sunlight patches through the windows for 15.00 hours, around the end of March

For the same hour a clear sky daylight simulation shows the daylight lux level distribution

False colour daylight distribution for the same hour

A summary of the CBDM metrics

CBDM metrics show that the UDIa at 66% is below the acceptable level. The UDIe at 32% indicates that there could well be excessive glare for about a third of occupied hours.

The UDIa distribution over the working plane shows poor performance in the front third of the space.

Again, the UDIe levels are excessive at the glazed end of the classroom The glazing configuration is meant to throw daylight to the back of the classroom, which is achieved, but at the expense of performance closer to the windows.

This new configuration of windows has the middle row removed. The high level windows still throw light to the back of the space and the view is maintained by the lower row of windows.

A daylight analysis for 15:00 hours at the end of March shows that a useful amount of daylight is reaching the back of the room via the high level windows. Also the amount of direct sunlight next to the windows is reduced.

This time the UDIa is at 85% giving a very good performance. UDIe is at an acceptable level. High level windows have given a good general distribution of daylight and the low level view windows do not produce excessive glare.

The UDIa distribution is quite flat, which is ideal.

UDIe is confined to close to the view windows.

The high level windows at the front and back of the room are good for daylight distribution, but are also very useful for natural ventilation combined with some limited view window opening. The reduction in lighting gains has also helped to achieve a pass on BB101 with the London TRY weather set, and on TM52 when using the same weather set. Performance metrics can be output to Excel or pdf as shown.

An alternative to removing the middle row of windows would be to provide some solar shading to reduce the direct sunlight through these windows. This configuration also had good CBDM metrics. Both configurations worked well on all orientations. This façade solution is but one of many that would comply with the CBDM criteria

To provide an insight into the single number metrics for the whole year, they are available on a monthly, weekly and hourly basis. The secret to a successful solution is to have the ‘Excessive’ level consistently low over the year.

Weekly distribution

Hourly distribution

The Tas daylight engine is able to provide analysis for BREEAM and LEED daylight credits. It is also able to undertake all Right to Light calculations, including the import of 3D DWG cityscape models.