News Gas and Oil Boilers 15. 06. 2015 Günther Köb / David Bini / Gerhard Werle
News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Training overview TopGas comfort Installation TopTronic® E Installation RS-OT Circulation pump UPM3 (Connection PWM) Parameterization TopTronic® E for TopGas comfort Mouting wall casing for TopTronic® E © Hoval / Nov-18 Hoval © Hoval
News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Training overview TopGas (35 – 120) New pump group with UPM2, UPM Geo (PWM - connection) UltraGas (15 – 100) New Ignicion model Installation and wiring module expansion/ Control modules Parameterization TopTronic® E for UltraGas (15 – 100) © Hoval / Nov-18 Hoval © Hoval
News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Training overview MultiJet (12 – 25) UltraOil (16 – 80) Installation and wiring module expansion / Control modules OFM (Oil-function-device) Parameterization TopTronic® E for MultiJet (12 – 25) Parameterization TopTronic® E for UltraOil (16 – 80) UltraOil (110 – 600D) New controller casing for TopTronic® E Parameterization TopTronic® E for UltraOil (110 – 600D) Upgraded combustion chamber insertion © Hoval / Nov-18 Hoval © Hoval
News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Product news Gas boilers 2015/16 TopGas comfort Boiler– Set with TopTronic® E Boiler– Set with RS-OT New circulation pump UPM3 (PWM) TopGas classic / combi Boiler– Set with TopTronic® E (incl. Wall casing) TopGas (35 – 120) NEW: TopGas (120) (116 kW) New pump group with UPM2, UPM Geo (PWM) © Hoval / Nov-18 © Hoval / Nov-18 Hoval Hoval 5 © Hoval
News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Product news Gas boilers 2015/16 UltraGas (15 – 100): With TopTronic® E New Ignition (external) UltraGas (125 – 1000) UltraGas H (720, 1000) 8 bar - Version CompactGas (3500, 4200) prototypes © Hoval / Nov-18 © Hoval / Nov-18 Hoval Hoval 6 © Hoval
Product news Oil boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Product news Oil boilers 2015/16 MultiJet (12 - 25), UltraOil (16 - 80) With TopTronic® E UltraOil (110 – 600D) With TopTronic® E with new controller casing Upgraded combustion chamber insertion New controller casing with TopTronic E® and OFA for medium– and big boilers: Uno-3 (95 – 360) Max-3 (420 – 2700), Max-3 plus (420 – 2700) CompactGas (700 – 2800) © Hoval / Nov-18 Hoval © Hoval
Product news Gas boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Product news Gas boilers 2015/16 © Hoval / Nov-18 Hoval © Hoval
TopGas® comfort (10, 16, 22) With new controller 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® comfort (10, 16, 22) With new controller Can be installed in this boilers: ControlModule BasicModule heat generator (will be delivered seperatly!) Hoval TopGas® comfort (10, 16, 22) Without controller on request © Hoval / Nov-18 Hoval © Hoval
TopGas® comfort (10, 16, 22) with UPM3 15-75 New circulation pump 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® comfort (10, 16, 22) with UPM3 15-75 New circulation pump Type: UPM3 15-75 130 PWM HZ High-efficiency pump Speed controlled by PWM signal More discharge head © Hoval / Nov-18 Hoval © Hoval
TopGas® comfort (10, 16, 22) with UPM3 15-75 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® comfort (10, 16, 22) with UPM3 15-75 Left discharge head Boiler type Boiler DT Volume circulated TopGas Vaillant Elco Viessmann output comfort classic ecoTEC plus THISION S Vitodens 200-W UPM3 15-75 AX 13-4 Yonos PARA 7.0 UPM2 15-70 UPM2 15-50 mit Umschaltweiche ohne Umschaltweiche kW K ltr/h mbar 10 857 640 380 - 410 12 1'029 450 110 16 1'371 340 60 25 230 18 1'543 50 22 1'886 24 2'057 TopGas comfort (16) with the UPM3 15-75 (and reverse switch) at DT of 10 K has a left discharge head of 340 mbar (100% Pump loead, 70 W) ! Therewith an underfloor heating with 16 kW can be operated without an additional circulation pump and hydraulic switch! © Hoval / Nov-18 Hoval © Hoval
TopGas® classic (12, 18, 24, 30) with new controller 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® classic (12, 18, 24, 30) with new controller Hoval TopGas® classic (12-30) Without regulation on request © Hoval / Nov-18 Hoval © Hoval
TopGas® combi (21/18, 26/23, 32/18) with new controller 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® combi (21/18, 26/23, 32/18) with new controller © Hoval / Nov-18 Hoval © Hoval
TopGas® (35 – 120) News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® (35 – 120) No Boilers - Sets with TopTronic® E or RS-OT ! Can be built in the boiler: ControlModul BasicModule Heat generator (will be delivered separately!) © Hoval / Nov-18 Hoval © Hoval
Expansion of the range withTopGas® (120) 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® (35 - 120) Expansion of the range withTopGas® (120) TopGas® (120) Start: 01.04. 2015 © Hoval / Nov-18 Hoval © Hoval
Expansion of the range withTopGas® (120) 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® (35 - 120) Expansion of the range withTopGas® (120) TopGas® (120) Heat exchanger: Aluminium Monoblock Fan: Ebm NRG 137 Gas valve: Honeywell VR 4514 Venturi: Honeywell 450-010 (mit Einsatz) Firing device: BIC 335 © Hoval / Nov-18 Hoval © Hoval
Expansion of the range withTopGas® (120) 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® (35 - 120) Expansion of the range withTopGas® (120) TopGas® (120) Technical data: Firing output: 20.4 – 107.3 kW Nominal output (40°/ 30°C): 116 kW Nominal output (80°/ 60°C): 19.7 – 104.0 kW Nominal output (40°/ 30°C): 22.0 – 116.0 kW Dimensions: Width 900 mm Depth 600 mm Height 900 mm Watercontent: 7.0 ltr Weight (incl. casing): 110 kg © Hoval / Nov-18 Hoval © Hoval
with PWM connection for circulating pump 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® (35 - 120) with PWM connection for circulating pump Adapter for PWM – connection for circulating pump Plug for PWM signal Circulating pump Plug for fan Only for TopGas (35 – 120): Connection cable for the PWM – signal for circulatoin pump will be delivered separately ! © Hoval / Nov-18 Hoval © Hoval
New pump group (with PWM) 16.11.2018 News Gas and Oil Boilers 2015/16 TopGas® (35 - 120) New pump group (with PWM) © Hoval / Nov-18 Hoval © Hoval
UltraGas® (15 - 100) with new controller 16.11.2018 News Gas and Oil Boilers 2015/16 UltraGas® (15 - 100) with new controller Built in the boiler: ControlModul BasicModul Heat Generator Firing device © Hoval / Nov-18 Hoval © Hoval
UltraGas® (15 - 100) New ignition Gas valve with ignition transformer 16.11.2018 News Gas and Oil Boilers 2015/16 UltraGas® (15 - 100) New ignition Gas valve with ignition transformer With introduction of TopTronic E the UltraGas (15-100) will be equipped with a new ignition. Benefits: Increased reliability No high frequency - ignition Short ignition cable, therefore low losses Two-wire ignition (Ignition not again mass) Low heat loss over the boiler door Smaller sight glass © Hoval / Nov-18 Hoval © Hoval
UltraGas® (15 - 100) New ignition News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 UltraGas® (15 - 100) New ignition Ignition transformator on the gas valve Shorter ignition calbe Ignition electrode block: Ignition electrode Ionisation Sight glass © Hoval / Nov-18 Hoval © Hoval
UltraGas® (125 - 1000) with new controller 16.11.2018 News Gas and Oil Boilers 2015/16 UltraGas® (125 - 1000) with new controller Built in the boiler: ControlModul BasicModul Heat Generator Firing device © Hoval / Nov-18 Hoval © Hoval
Öl- / Gasheizkessel - Produktübersicht News Gas and Oil Boilers 2015/16 UltraGas® H (720, 1000) Maximum operating pressure: 8 bar In the catalogue from 01.07. 2015 (Delivery time: 8 weeks) © Hoval / Nov-18 Öl- / Gasheizkessel - Produktübersicht
Product news Oil boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Product news Oil boilers 2015/16 © Hoval / Nov-18 Hoval © Hoval
MultiJet (16 - 25) with new controller 16.11.2018 News Gas and Oil Boilers 2015/16 MultiJet (16 - 25) with new controller Built in the boiler: ControlModul BasicModul Heat Generator Oil – Function device OFA Oil automatic function device OFA -- Control function integrated for -- flue gas sensor for safety shut-off -- 0-10V output for connecting a modulating main pump (incl. delta T-control with low consumption) -- Standard plug connection for 2-stage burner 1x 230 V -- Variable input for plant-specific functions (heat generator block, return sensor, info sensor etc.) -- Variable output for plant-specific functions (thermostat function, operating message, etc.) © Hoval / Nov-18 Hoval © Hoval
UltraOil (16 - 80) with new controller 16.11.2018 News Gas and Oil Boilers 2015/16 UltraOil (16 - 80) with new controller Built in the boiler: ControlModul BasicModul Heat Generator Oil – function device OFA © Hoval / Nov-18 Hoval © Hoval
UltraOil (110 - 300) with new controller 16.11.2018 News Gas and Oil Boilers 2015/16 UltraOil (110 - 300) with new controller Built in the boiler: ControlModul BasicModul Heat Generator Oil– function device OFA © Hoval / Nov-18 Hoval © Hoval
Upgraded combustion chamber insertion 16.11.2018 News Gas and Oil Boilers 2015/16 UltraOil (110 - 300) Upgraded combustion chamber insertion Old Version ! Improvement: The wall thickness of the guide tube is increased to 1.5 mm. The combustion chamber insertion’s feets are not dotted anymore. But welded with 15mm sondern mit 15 mm long weldseams. The feets are widen to 130 mm to prevent an overturning of the insertion. Available: approx. 1 July 2015 © Hoval / Nov-18 Hoval © Hoval
for middle and big boilers: 16.11.2018 News Gas and Oil Boilers 2015/16 New controller casing for middle and big boilers: Boiler types: UltraOil (110 – 300) Uno-3 (95 – 360), Max-3 (420 – 2700) Max-3 plus (420 – 2700) CompactGas (700 – 2800) © Hoval / Nov-18 Hoval © Hoval
Composition new controller casing: 16.11.2018 News Gas and Oil Boilers 2015/16 Composition new controller casing: Firing device(OFA) Cable clip BasicModul Heat Generator (z.B.: ControlModul, Relay) Module expansion: 1 Module expansion 1 ControlModul or 2 ControlModule ControlModul Control panel © Hoval / Nov-18 Hoval © Hoval
Required space for the new controller casing: 16.11.2018 News Gas and Oil Boilers 2015/16 Required space for the new controller casing: © Hoval / Nov-18 Hoval © Hoval
Thermostatic controller for middle and big boilers: 16.11.2018 News Gas and Oil Boilers 2015/16 Thermostatic controller for middle and big boilers: The thermostatic controller T0.2 and T2.2 will stay in the product range for the business year 2015/16! Uno-3 (95 – 360), Max-3 (420 – 2700) Max-3 plus (420 – 2700) CompactGas (700 – 2800), Titan-3 (THWI – NTE) © Hoval / Nov-18 Hoval © Hoval
Product information Oil boiler 16.11.2018 News Gas and Oil Boilers 2015/16 Product information Oil boiler © Hoval / Nov-18 Hoval © Hoval
Oil pump of HLZ 45 AV/BV News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Oil pump of HLZ 45 AV/BV Actual status: The fault rate of the Danfoss BFP52 EL3 oil pump increases every year! The returned oil pumps were checked (at Herrmann and Hoval). In the process it was discovered that 2/3 of the oil pumps were OK. Possible reasons why the oil pumps were changed: Variation oil pressure Operating noise Deepening oil pressure © Hoval / Nov-18 Hoval © Hoval
Oil pump of HLZ 45 AV/BV News Gas and Oil Boilers 2015/16 16.11.2018 News Gas and Oil Boilers 2015/16 Oil pump of HLZ 45 AV/BV Technic of the oil pump: Since 2010 the Danfoss oil pumps have a gear set made out of sintered material. Before the gears were made out of steel. The sintered gear sets are more sensitive as the ones made out of steel because there are an increased abrasion. Therefore the following notes have to be kept in mind: Correct dimmenssioning of the oil pipe ! Tight oil pipe ! During commissioning of the plant the oil has to be suced with the manual pump. Suction with the oil pump is not allowed! © Hoval / Nov-18 Hoval © Hoval
Günther Köb – Produktmanager – Hoval Vaduz